Determination of 27 Elements in Animal Feed by Inductively Coupled Plasma-Mass Spectrometry

被引:12
|
作者
King, Thomas [1 ]
Sheridan, Robert [1 ]
机构
[1] New York State Dept Agr & Markets Food Lab, 1220 Washington Ave, Albany, NY 12235 USA
关键词
RICE BRAN; CATTLE; COPPER; LEAD; INTOXICATION; TOXICITY; TISSUES;
D O I
10.5740/jaoacint.18-0198
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method was developed to determine 27 elements (aluminum, arsenic, boron, cadmium, calcium, chromium, cobalt, copper, iron, lead, magnesium, manganese, mercury, molybdenum, nickel, phosphorus, potassium, selenium, sodium, sulfur, vanadium, zinc, antimony, uranium, beryllium, thallium, and thorium) in animal feeds and pet foods using closed vessel microwave digestion and inductively coupled plasma-mass spectrometry. These elements can adversely affect animal health when amounts become excessive or deficient in food. For potentially toxic elements, the target LOQ was determined to be 1/10 the lowest maximum tolerable level (MTL) for the most sensitive animal species. For nutritionally essential elements, the target LOQ was determined to be 1/10 the concentration that would be considered deficient in feed if that level is lower than 1/10 the lowest MTL. The targeted high end of the quantitation range was selected as twice the highest MTL. A single-laboratory validation (SLV) was performed to determine the accuracy and precision of the method, and the results were evaluated with respect to predetermined performance characteristics. The test materials used in the SLV included two National Institute of Standards and Technology certified reference materials, two Association of American Feed Control Officials (AAFCO) check samples, and one in-house previously analyzed feed sample. The concentrations of each element determined were the result of spiked analyte, incurred analyte, or a combination of spiked and incurred analyte. All samples were analyzed seven times on different days at 2 x LOQ and at the midrange concentration. For most data, the results of the SLV met or exceeded the criteria for accuracy and repeatability. For accuracy, K at the midrange level had a mean recovery of 95%, which is just below the low preferred accuracy threshold of 97%. For repeatability, all the 2 x LOQ CVr values were below the preferred values. Be, Cr, Ni, Na, Mn, and S all had midrange CVr values exceeding the preferred values. Be had the highest midrange CVr value of 9.93. Eight AAFCO check samples were also analyzed to determine the method's accuracy and repeatability for elements at the manufacturer's claimed levels. For accuracy, all results had z-scores <1.5. For repeatability, three CVr values from two AAFCO check samples were greater than the preferred limits.
引用
收藏
页码:434 / 444
页数:11
相关论文
共 50 条
  • [21] DETERMINATION OF BROMINE IN HUMAN SERUM BY INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY
    VANDECASTEELE, C
    VANHOE, H
    DAMS, R
    VERSIECK, J
    ANALYTICAL LETTERS, 1990, 23 (10) : 1827 - 1841
  • [22] Determination method with hydride generation and inductively coupled plasma-mass spectrometry
    He, M
    Lin, SL
    Hu, SH
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2002, 22 (03) : 464 - 469
  • [23] Determination Method with Hydride Generation and Inductively Coupled Plasma-Mass Spectrometry
    He, Man
    Lin, Shou-Lin
    Hu, Sheng-Hong
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2002, 22 (03): : 20 - 469
  • [24] Determination of antimony in human blood with inductively coupled plasma-mass spectrometry
    Bazzi, A
    Nriagu, JO
    Inhorn, MC
    Linder, AM
    JOURNAL OF ENVIRONMENTAL MONITORING, 2005, 7 (12): : 1251 - 1254
  • [25] Determination of boron isotope abundance by inductively coupled plasma-mass spectrometry
    Bai Peng
    Li Xiaofeng
    Wu Jun
    Guo Hongjie
    Li Xingang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (09) : 1338 - 1340
  • [26] Indirect determination of protein content by inductively coupled plasma-mass spectrometry
    Wang Meng
    Feng Wei-Yue
    Lu Wen-Wei
    Li Bai
    Wang Bing
    Zhu Mo-Tao
    Wang Yun
    Zhao Yu-Liang
    Chai Zhi-Fang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (03) : 321 - 324
  • [27] Iodine determination in animal feed by inductively coupled plasma mass spectrometry - results of a collaborative study
    Jerse, Ana
    Amlund, Heidi
    Rasmussen, Rie R.
    Sloth, Jens J.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (02): : 261 - 267
  • [28] Iodine determination in animal feed by inductively coupled plasma mass spectrometry–results of a collaborative study
    Jerše, Ana
    Amlund, Heidi
    Rasmussen, Rie R.
    Sloth, Jens J.
    Food Additives and Contaminants - Part A Chemistry, Analysis, Control, Exposure and Risk Assessment, 2021, 38 (02): : 261 - 267
  • [29] INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY OF SYNTHETIC ELEMENTS - TC-99
    CRAIN, JS
    GALLIMORE, DL
    APPLIED SPECTROSCOPY, 1992, 46 (03) : 547 - 549
  • [30] The determination of 18 trace elements in lichens for atmospheric monitoring using inductively coupled plasma-mass spectrometry
    Yun, M
    Longerich, HP
    Wadleigh, MA
    CANADIAN JOURNAL OF ANALYTICAL SCIENCES AND SPECTROSCOPY, 2003, 48 (03): : 171 - 180