Integral experiments on thorium assemblies with D-T neutron source

被引:0
|
作者
Liu, Rong [1 ]
Yang, Yiwei [1 ]
Feng, Song [1 ]
Zheng, Lei [1 ]
Lai, Caifeng [1 ]
Lu, Xinxin [1 ]
Wang, Mei [1 ]
Jiang, Li [1 ]
机构
[1] China Acad Engn Phys, Key Lab Neutron Phys, Inst Nucl Phys & Chem, Mianyang 621900, Sichuan, Peoples R China
关键词
HYBRID REACTOR; BLANKET;
D O I
10.1051/epjconf/201714606022
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
To validate nuclear data and code in the neutronics design of a hybrid reactor with thorium, integral experiments in two kinds of benchmark thorium assemblies with a D-T fusion neutron source have been performed. The one kind of 1D assemblies consists of polyethylene and depleted uranium shells. The other kind of 2D assemblies consists of three thorium oxide cylinders. The capture reaction rates, fission reaction rates, and (n, 2n) reaction rates in Th-232 in the assemblies are measured by ThO2 foils. The leakage neutron spectra from the ThO2 cylinders are measured by a liquid scintillation detector. The experimental uncertainties in all the results are analyzed. The measured results are compared to the calculated ones with MCNP code and ENDF/B-VII.0 library data.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] NEUTRON AND GAMMA-RADIATION FROM A NITROGEN SPHERE SURROUNDING A D-T NEUTRON SOURCE
    SIDHU, GS
    FARLEY, WE
    HANSEN, LF
    KOMOTO, T
    POHL, B
    WONG, C
    NUCLEAR SCIENCE AND ENGINEERING, 1977, 63 (01) : 48 - 54
  • [22] CALCULATED NEUTRON-TRANSPORT VERIFICATIONS BY INTEGRAL 14 MEV-NEUTRON SOURCE EXPERIMENTS WITH MULTIPLYING ASSEMBLIES
    ZAGRYADSKII, VA
    MARKOVSKII, DV
    NOVIKOV, VM
    CHUVILIN, DY
    SHATALOV, GE
    FUSION ENGINEERING AND DESIGN, 1989, 9 : 353 - 358
  • [23] Radiation shielding design of BNCT treatment room for D-T neutron source
    Pouryavi, Mehdi
    Masoudi, S. Farhad
    Rahmani, Faezeh
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 90 - 96
  • [24] EVALUATION OF MINIMUM NEUTRON SOURCE STRENGTH REQUIRED FOR IGNITION OF D-T FUEL
    MURUKESAPILLAI, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1992, 61 (09) : 3125 - 3133
  • [25] A moveable neutron imaging facility using D-T neutron source based on a compact accelerator
    Wang, Sheng
    Yin, Wei
    Liu, Bin
    Li, Hang
    Sun, Yong
    Cao, Chao
    Wu, Yang
    Huo, He-Yong
    Zhu, Shi-Lei
    Lou, Ben-Chao
    Wu, Chun-Lei
    Tang, Bin
    APPLIED RADIATION AND ISOTOPES, 2021, 169
  • [26] A method to improve the sensitivity of neutron porosity measurement based on D-T source
    Liu, Juntao
    Zhang, Feng
    Gardner, Robin P.
    Hou, Guojing
    Zhang, Quanying
    Zhang, Yan
    Li, Xianghui
    Li, Hu
    Hu, Cong
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2016, 33 : 879 - 884
  • [27] FAST-NEUTRON SPECTRUM IN LITHIUM-FLUORIDE PILE WITH D-T NEUTRON SOURCE
    LEE, DW
    SEKIMOTO, H
    YAMAMURO, N
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1985, 22 (01) : 28 - 37
  • [28] The design of “multiple energies from one source” in D-T neutron tube
    Hui-Ping Guo
    Kuo Zhao
    Ning Lü
    Zhi-Hao Wei
    Wen-Hui Lü
    Nuclear Science and Techniques, 2016, 27
  • [29] The design of "multiple energies from one source'' in D-T neutron tube
    Guo, Hui-Ping
    Zhao, Kuo
    Lu, Ning
    Wei, Zhi-Hao
    Lu, Wen-Hui
    NUCLEAR SCIENCE AND TECHNIQUES, 2016, 27 (05)
  • [30] A comparative study of neutron stimulated emission computed tomography based on D-D/D-T neutron source
    Zhao Liang
    Fan YaMing
    Dong Ming
    Li YingGuo
    Wang TianQuan
    Li ZhongXing
    Tong LinGe
    Yin YongZhi
    Chen XiMeng
    SCIENTIA SINICA-PHYSICA MECHANICA & ASTRONOMICA, 2018, 48 (02)