Half-Time SPECT Acquisition with Resolution Recovery for Tc-MIBI SPECT Imaging in the Assessment of Hyperparathyroidism

被引:7
|
作者
Bar, Ronen [2 ]
Przewloka, Kinga [1 ]
Karry, Rachel [1 ]
Frenkel, Alex [1 ]
Golz, Avishay [2 ,3 ]
Keidar, Zohar [1 ,3 ]
机构
[1] Rambam Hlth Care Campus, Dept Nucl Med, Haifa, Israel
[2] Rambam Hlth Care Campus, Dept Otolaryngol Head & Neck Surg, Haifa, Israel
[3] Technion Israel Inst Technol, B&R Rappaport Fac Med, Haifa, Israel
关键词
Parathyroid adenoma; SPECT; Tc-MIBI; Resolution recovery; PHASE;
D O I
10.1007/s11307-011-0530-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reduced SPECT acquisition time protocols have been recently developed based on collimator-detector response compensation reconstruction. The present study aims to evaluate the potential use of a short-time technetium-99m methoxyisobutylisonitrile (Tc99m-MIBI) SPECT algorithm in the investigation of parathyroid adenoma (PTA). Ninety patients (59 women; age range, 21-76 years) with biochemical evidence of hyperparathyroidism were referred for Tc99m-MIBI scintigraphy for diagnosis and localization of PTA. Standard full-time and half-time SPECT studies starting at 45 min after injection were performed in random order in all patients. PTA detection rate and overall image quality parameters were evaluated and graded for each study and compared for the two SPECT protocols. Focal Tc-99m-sestamibi uptake consistent with PTA was reported in 60 out of 90 studies (67%). Congruent results between the full- and half-time SPECT acquisition were found in 73 patients (81%). Minor disagreement between the two SPECT protocols with respect to PTA detectability was found in 17 patients but with no statistically significant difference (p = 0.67). The correlation coefficient between the two SPECTs was r = 0.88 (p < 0.0001), and the Bland-Altman correlation analysis confirmed the interchangeability of the two protocols. Image quality was reported as either good or excellent for all studies, and no statistical significant difference in image quality scoring between protocols was found (p = 0.155). Parathyroid MIBI SPECT can be performed using the collimator-detector response compensation reconstruction algorithm for only half of the scanning time without compromising significant diagnostic data.
引用
收藏
页码:647 / 651
页数:5
相关论文
共 50 条
  • [31] Tc-99m-MIBI scintimammography; SPECT versus planar imaging
    Aziz, A
    Hashmi, R
    Ogawa, Y
    Hayashi, K
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 1999, 14 (06) : 495 - 500
  • [32] SPECT IMAGING OF BRAIN-TUMORS WITH TC-99M MIBI
    BAGNI, B
    TAMAROZZI, R
    CALZOLARI, F
    CERUTI, S
    PINNA, L
    RADIOLOGY, 1992, 185 : 233 - 233
  • [33] A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT
    DePuey, E. Gordon
    Bommireddipalli, Srinivas
    Clark, John
    Leykekhman, Anna
    Thompson, Linda B.
    Friedman, Marvin
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (02) : 273 - 280
  • [34] Tc-99m-MIBI brain spect imaging of intracranial tumors
    Kaprelyan, A. G.
    NEURO-ONCOLOGY, 2006, 8 (04) : 372 - 372
  • [35] A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT
    E. Gordon DePuey
    Srinivas Bommireddipalli
    John Clark
    Anna Leykekhman
    Linda B. Thompson
    Marvin Friedman
    Journal of Nuclear Cardiology, 2011, 18 : 273 - 280
  • [36] Atypical non-[99mTc]Tc-MIBI avid parathyroid adenoma with a sternal brown tumor, mimicking ectopic parathyroid adenoma in planar and SPECT images: Importance of SPECT/CT acquisition
    Roustaei, Hessamoddin
    Yaghoubi, Mohammad Ali
    Golestani, Zahra Bakhshi
    Sadrizadeh, Ali
    Sadeghi, Ramin
    Barashki, Somayeh
    Aghaee, Atena
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2022, 30 (01): : 76 - 79
  • [37] 99mTc-MIBI SPECT/CT imaging contribution in the diagnosis of patients with hyperparathyroidism
    Nevena, Manevska
    Sinisa, Stojanoski
    Bojana, Stoilovska
    Irena, Sazdova
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 27 (01): : 1 - 7
  • [39] THE VALUE OF 99M 2-TC-METHOXYISOBUTYL-ISONITRILE TECHNETIUM (99M TC-MIBI) SPECT IMAGING IN SUPRATENTORIAL BRAIN-TUMORS
    ALBUQUERQUE, L
    BAILLET, G
    CHEN, Q
    POISSON, M
    DELATTRE, JY
    NEUROLOGY, 1993, 43 (04) : A249 - A249
  • [40] Reduced SPECT imaging time with ordered subset expectation maximum and resolution recovery
    Jimenez-Heffernan, A.
    Sanchez De Mora, E.
    Lopez-Martin, J.
    Lopez-Aguilar, R.
    Ramos, C.
    Salgado, C.
    Ortega, A.
    Sanchez-Gonzalez, C.
    Roa, J.
    Tobaruela, A.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2011, 13 (0A) : A86 - A86