A Comparison of Conventional Intravitreal Injection Method vs InVitria Intravitreal Injection Method

被引:3
|
作者
Blyth, Michelle [1 ]
Innes, William [1 ]
Mohsin-Shaikh, Nyma [1 ]
Talks, James [1 ]
机构
[1] Royal Victoria Infirm, Newcastle Eye Ctr, Newcastle Upon Tyne NE1 4LP, Tyne & Wear, England
来源
CLINICAL OPHTHALMOLOGY | 2020年 / 14卷
关键词
InVitria; drape; speculum; visual analogue scale; pain scores; VISUAL ANALOG SCALE; PAIN;
D O I
10.2147/OPTH.S238529
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare use of the conventional intravitreal injection method to the InVitria intravitreal injection device. Three outcome measures were studied: patient comfort, speed of injection and cost-effectiveness. Patients and Methods: A prospective review of 58 patients was undertaken. Patients scored their perceived pain for each part of the conventional injection method using visual analogue scales (VAS), which allows pain to be scored from 0 (no pain) to 100. The same 58 patients scored their perceived pain for each part of the injection process with the InVitria on their follow-up visit. The procedure was timed in both settings and cost to the Trust was analysed. Results: Pain scores when the InVitria was used were lower than when the conventional method was used for all aspects of the intravitreal injection procedure, in particular, when comparing insertion of drape/speculum (mean score 57.56) to insertion the InVitria (mean score 16.50), needle entry (mean score 37.76 to 27.86) and removal of the drape/speculum (mean score 38.72) to removal of the InVitria (11.07). The reduction in pain scores was statistically significant for all aspects of the procedure, except the initial instillation of drops. The InVitria was an average of 1 minute and 32 seconds faster than the conventional method. Use of the InVitria in place of the conventional method provides an annual saving of 24,300 pound to the Trust based on the number of injections currently performed. Conclusion: The introduction of the InVitria in the Newcastle Eye Centre has had a positive impact on patient comfort, time and cost to the Trust.
引用
收藏
页码:2507 / 2513
页数:7
相关论文
共 50 条
  • [11] Intravitreal Injection Technique
    Garay-Aramburu, Gonzaga
    Cabrerizo, Javier
    OPHTHALMOLOGY, 2012, 119 (12) : 2654 - 2655
  • [12] Intravitreal injection benchmarking and optimization Analysis and process optimization of the intravitreal injection pathway
    Saria, Katrin
    Pferzinger, Manfred
    Radda, Stephan
    Findl, Oliver
    SPEKTRUM DER AUGENHEILKUNDE, 2019, 33 (05) : 117 - 127
  • [13] An improved method of centrifuge concentration of triamcinolone acetonide (Triesence) for intravitreal injection
    Cunningham, Christy Marie
    Becker, Karl N.
    Keen, Jamie
    Lamba, Neerav
    Becker, Norbert M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [14] An intravitreal implant injection method for sustained drug delivery into mouse eyes
    Sun, Young Joo
    Lin, Cheng-Hui
    Wu, Man-Ru
    Lee, Soo Hyeon
    Yang, Jing
    Kunchur, Caitlin R.
    Mujica, Elena M.
    Chiang, Bryce
    Jung, Youn Soo
    Wang, Sui
    Mahajan, Vinit B.
    CELL REPORTS METHODS, 2021, 1 (08):
  • [15] A simple and rapid method for purification of triamcinolone acetonide suspension for intravitreal injection
    Hernaez-Ortega, MC
    Soto-Pedre, E
    OPHTHALMIC SURGERY LASERS & IMAGING, 2004, 35 (04): : 350 - 351
  • [16] Customized disposable kit versus a conventional stainless steel instrument for an intravitreal injection: A comparison
    Khaqan, Hussain Ahmad
    Imtiaz, Usman
    Malik, Irfan Qayyum
    Qureshi, Bilal Zaheer
    Ateeq-ur-Rehman
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (05) : 909 - 912
  • [17] Safety and Efficacy of Intravitreal Ocriplasmin in Diabetic Macular Edema with Vitreomacular Adhesion - results of a guided intravitreal injection method
    Coelho, Joao
    Pessoa, Bernardete
    Correia, Nuno Alves
    Beirao, Joao Melo
    Meireles, Angelina
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [18] Comparison of topical and subconjunctival anesthesia in intravitreal injection administrations
    Kaderli, B.
    Avci, R.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2006, 16 (05) : 718 - 721
  • [19] Comparison of Two Anesthetic Methods for Intravitreal Ozurdex Injection
    Karabas, V. Levent
    Ozkan, Berna
    Kocer, Cigdem Akdag
    Altintas, Ozgul
    Pirhan, Dilara
    Yuksel, Nursen
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [20] Inadvertent intravitreal gentamicin injection
    Burgansky, Z
    Rock, T
    Bartov, E