An Implantable Bio-Micro-system for Drug Monitoring

被引:0
|
作者
Ghoreishizadeh, Sara [1 ]
Kilinc, Enver G. [2 ]
Baj-Rossi, Camilla [1 ]
Dehollain, Catherine [2 ]
Carrara, Sandro [1 ]
De Micheli, Giovanni [1 ]
机构
[1] Ecole Polytech Fed Lausanne, LSI, CH-1015 Lausanne, Switzerland
[2] RFIC, CH-1015 Lausanne, Switzerland
基金
瑞士国家科学基金会;
关键词
Cyclic voltammetry measurement; Drug detection; Power management; Inductive coil; Readout circuit; Integrated circuit;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Multi-target and continuous monitoring by wireless implantable devices is of increasing interest for personalized therapy. In this work an implantable system is presented which is capable of measuring different drugs with Cyclic Voltammetry (CV) method. The wireless microsystem consists of four modules, namely (i) The inductive coil; (ii) Power management IC; (iii) Readout and control IC; (iv) Biosensor array. The power management IC provides 1.8 V with as high as 2 mW power for the readout IC. The configurable readout IC is able to control the biosensor array and measure the sensor current in CV method. CV experiments performed with this microsystem well agree with a commercial equipment for two well known anti-cancer drugs, Etoposide and Mitoxantrone, detection.
引用
收藏
页码:218 / 221
页数:4
相关论文
共 50 条
  • [31] A Bluetooth Low Energy Implantable Glucose Monitoring System
    Ali, Mai
    Albasha, Lutfi
    Al-Nashash, Hasan
    2011 8TH EUROPEAN RADAR CONFERENCE, 2011, : 377 - 380
  • [32] Implantable devices for heart failure monitoring: the CardioMEMS™ system
    Volterrani, Maurizio
    Spoletini, Ilaria
    Angermann, Christiane
    Rosano, Giuseppe
    Coats, Andrew Js
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0M) : M50 - M53
  • [33] A linear voltage regulator for an implantable device monitoring system
    Crepaldi, Paulo Cesar
    Pimenta, Tales C.
    Moreno, Robson L.
    Rodriguez, Edgard Charry
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2010, 65 (01) : 131 - 140
  • [34] Development of a fully implantable wireless pressure monitoring system
    Robert Tan
    Timothy McClure
    C. K. Lin
    David Jea
    Foad Dabiri
    Tammara Massey
    Majid Sarrafzadeh
    Mani Srivastava
    C. D. Montemagno
    Peter Schulam
    Jacob Schmidt
    Biomedical Microdevices, 2009, 11 : 259 - 264
  • [35] A linear voltage regulator for an implantable device monitoring system
    Paulo Cesar Crepaldi
    Tales C. Pimenta
    Robson L. Moreno
    Edgard Charry Rodriguez
    Analog Integrated Circuits and Signal Processing, 2010, 65 : 131 - 140
  • [36] Assessment of a remote monitoring system for implantable cardioverter defibrillators
    Masella, Cristina
    Zanaboni, Paolo
    Di Stasi, Francesca
    Gilardi, Serena
    Ponzi, Patrizia
    Valsecchi, Sergio
    JOURNAL OF TELEMEDICINE AND TELECARE, 2008, 14 (06) : 290 - 294
  • [37] Value of the implantable doppler system in free flap monitoring
    Smit, J. M.
    Klein, S.
    de Jong, E. H.
    Zeebregts, C. J.
    de Bock, G. H.
    Werker, P. M. N.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2012, 65 (09): : 1276 - 1277
  • [38] Development of a fully implantable wireless pressure monitoring system
    Tan, Robert
    McClure, Timothy
    Lin, C. K.
    Jea, David
    Dabiri, Foad
    Massey, Tammara
    Sarrafzadeh, Majid
    Srivastava, Mani
    Montemagno, C. D.
    Schulam, Peter
    Schmidt, Jacob
    BIOMEDICAL MICRODEVICES, 2009, 11 (01) : 259 - 264
  • [39] Wearable wireless telemetry system for implantable Bio-MEMS sensors
    Simons, Rainee N.
    Miranda, Felix A.
    Wilson, Jeffrey D.
    Simons, Renita E.
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 2155 - +
  • [40] Implantable 400MHz PIFA for Bio-telemetry System
    Islam, M. Shahidul
    Esselle, K. P.
    Matekovits, L.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2015, : 537 - 540