On-line galvanic cell generated electrochemiluminescence determination of acyclovir based on the flow injection sampling

被引:21
|
作者
Lv, J [1 ]
Luo, LR [1 ]
Zhang, ZJ [1 ]
机构
[1] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
electrochemiluminescence (ECL); acyclovir; on-line galvanic cell; flow injection (Fl);
D O I
10.1016/j.aca.2003.12.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new simple, rapid and cost effective flow injection (FI) electrochemiluminescence (ECL) method was described for the determination of acyclovir (9,2-hydroxyethoxy) methyl guanine. In the presence of acyclovir, the luminol electrochemiluminescence generated by a mini on-line galvanic cell could be greatly sensitized in alkaline medium. The relative electrochemiluminescence intensity was found to increase linearly with increasing concentration of acyclovir, which was corroborated by the calculated correlation coefficient value of 0.9994 (n = 7). The limit of detection was 1.6 x 10(-7) mol l(-1) and the limit of quantification was 7.9 x 10(-7) mol l(-1). The proposed method was applied to the determination of acyclovir in pharmaceutical formulations. The reliability of the assay method was established by parallel determination and by standard-addition method. Experiment results demonstrated the described mini analysis system, while being simple and less time consuming, was accurate, precise and reproducible (R.S.D. = 1.6%, recoveries = 99-103%). Further experiments indicated that there was no significant difference between the results obtained by the proposed and official methods. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 39
页数:5
相关论文
共 50 条
  • [21] On-line determination of mercury(II) by membrane separation flow injection analysis
    Amini, N
    Cardwell, TJ
    Cattrall, RW
    Morrison, RJS
    Kolev, SD
    TALANTA, 2004, 63 (04) : 1069 - 1075
  • [22] On-line removal of sulfide interference in phosphate determination by flow injection analysis
    Grace, Michael
    Udnan, Yuthapong
    McKelvie, Ian
    Jakmunee, Jaroon
    Grudpan, Kate
    ENVIRONMENTAL CHEMISTRY, 2006, 3 (01) : 19 - 25
  • [23] On-line flow injection-pervaporation of beer samples for the determination of diacetyl
    IzquierdoFerrero, JM
    FernandezRomero, JM
    deCastro, MDL
    ANALYST, 1997, 122 (02) : 119 - 122
  • [24] Determination of doxium by flow injection analysis with on-line redox and coloration reactions
    Wei, YF
    Ma, DM
    Lang, HY
    Chang, X
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (10) : 1375 - 1377
  • [25] On-line preconcentration and determination of iron by flow injection analysis in nuclear fuels
    S. Chandramouleeswaran
    Jayshree Ramkumar
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 318 : 2073 - 2077
  • [26] On-line preconcentration and determination of iron by flow injection analysis in nuclear fuels
    Chandramouleeswaran, S.
    Ramkumar, Jayshree
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 318 (03) : 2073 - 2077
  • [27] ON-LINE FLOW INJECTION SPECTROPHOTOMETRIC DETERMINATION OF CHLORIDE ION IN TANNERY EFFLUENT
    Yu Lingyun
    Zhang Xinshen
    Sun Dongmie
    Tong Ling
    Dai Shijun
    Xiao Kai
    Tu Jie
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2009, 93 (02): : 46 - 50
  • [28] On-Line Determination of Nitrite in Tannery Effluent by Reverse Reference Flow Injection
    Yu Lingyun
    Zhang Xinshen
    Xiao Kai
    Yu Lan
    Cao Fengmei
    Zhao Huanhuan
    Sun Jing
    Yang Yujie
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2010, 94 (03): : 124 - 128
  • [29] On-line determination of tannic acid in leather wastewater by flow injection spectrophometry
    Wei Liang
    Zhang Xinshen
    Huang Jin
    Xie Yonghong
    Xiao Kai
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2008, 92 (03): : 127 - 129
  • [30] Determination of nitrofuraIntoin by flow injection on-line filtration atomic absorption spectrometry
    Xie, ZH
    Wang, YT
    Lang, HY
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (01) : 66 - 69