Non-Invasive Tear Break-Up Detection with the Kowa DR-1α and Its Relationship to Dry Eye Clinical Severity

被引:4
|
作者
Pflugfelder, Stephen [1 ]
Nakhleh, Lauren [1 ]
Kikukawa, Yasushi [2 ]
Tanaka, Shin [2 ]
Kosugi, Takuya [3 ]
机构
[1] Baylor Coll Med, Dept Ophthalmol, Houston, TX 77030 USA
[2] Kowa Co Ltd, Tokyo 1038433, Japan
[3] Kowa Res Inst Inc, Kowa Ophthalm Res Labs, Boston, NC 27560 USA
关键词
break-up; dry; eye; interferometer; non-invasive; tear; stability; PREVALENCE; DISEASE;
D O I
10.3390/ijms232314774
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The purpose of this study is to compare visual versus software detection of non-invasive tear break-up with the KOWA DR-1 alpha tear interferometer and investigate the relationship between non-invasive tear break-up time (NIBUT) and dry eye clinical severity. Tear interferometry with the KOWA DR-1 alpha, together with a standardized comprehensive ocular surface/tear evaluation, was performed on 348 consecutive eyes. Investigator visually detected or software detected non-invasive tear break-up and NIBUT were measured and compared on a subset of these examinations. The relationship between software-detected NIBUT and categorical dry eye severity based on irritation symptoms and corneal and conjunctival dye staining scores was determined. The sensitivity of visual (frame-by-frame) or software detected non-invasive tear break-up in eyes with tear instability (FBUT < 10) was similar (range 63-69%). NIBUT, measured visually or by software, had a correlation coefficient of 0.87. NIBUT was significantly lower in severity levels 2 and 3 compared to levels 0 + 1, and level 3 was significantly lower than level 2. In conclusion, there is a good correlation between investigator visually detected and software-detected tear break-up and tear break-up time in the KOWA DR-1 alpha interferometric fringe images. Software-detected NIBUT is a clinically relevant measure of dry eye clinical severity.
引用
收藏
页数:7
相关论文
共 40 条
  • [31] Comparing automated and manual assessments of tear break-up time using different non-invasive devices and a fluorescein procedure
    Zeri, Fabrizio
    Rizzo, Giulia Carlotta
    Ponzini, Erika
    Tavazzi, Silvia
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [32] The association of vitamin D deficiency with tear break-up time and Schirmer testing in non-Sjögren dry eye
    B E Kurtul
    P A Özer
    M S Aydinli
    Eye, 2015, 29 : 1081 - 1084
  • [33] A novel method of evaluating the non-invasive tear film break-up time and progression of corneal opacification in dogs using imaging video
    Lee, Suk Jun
    Han, Myeong Gyun
    Yang, Su-Jung
    Choi, Yun-Soo
    Kim, Joon Young
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11
  • [34] All-in one automated measurement of ocular surface parameters: interferometry, tear meniscus, non-invasive break-up time and meibography
    Courrier, E.
    Trone, M. C.
    Renault, D.
    Lambert, V.
    Lazreg, S.
    Thuret, G.
    Gain, P.
    ACTA OPHTHALMOLOGICA, 2018, 96 : 25 - 25
  • [35] Analysis of the first tear film break-up point in Sjogren's syndrome and non-Sjogren's syndrome dry eye patients
    Zhao, Songjiao
    Le, Qihua
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [36] Nichtinvasive Keratographen-Tränenfilmaufreißzeit im Vergleich zur Fluoreszein-TränenfilmaufreißzeitComparison of non-invasive tear film break-up time assessed by keratography with conventional fluorescein tear film break-up time
    Bujar Berisha
    Johannes Nepp
    Dieter Franz Rabensteiner
    Georg Wagner
    Ingrid Boldin
    Haleh Aminfar
    Jutta Horwath-Winter
    Spektrum der Augenheilkunde, 2022, 36 : 139 - 144
  • [37] The relationship between fluorescein break-up patterns and symptoms of dry eye in non-contact lens and contact lens wearers
    Elving-Kokke, K. H.
    van Tilborg, M.
    Zeeman, J.
    Kunnen, C.
    ACTA OPHTHALMOLOGICA, 2020, 98 : 3 - 3
  • [38] Analysis of tear fluid proteins in dry-eye by protein-chips: A new non-invasive approach for biomarker detection
    Wirthlin, A
    Pfeiffer, N
    Grus, FH
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U142 - U142
  • [39] Analysis of the first tear film break-up point in Sjögren’s syndrome and non-Sjögren’s syndrome dry eye patients
    Songjiao Zhao
    Qihua Le
    BMC Ophthalmology, 22
  • [40] Pre-Lens Tear Meniscus Height, Lipid Layer Pattern and Non-Invasive Break-Up Time Short-Term Changes with a Water Gradient Silicone Hydrogel Contact Lens
    Capote-Puente, Raul
    Bautista-Llamas, Maria-Jose
    Manzoni, Caterina
    Sanchez-Gonzalez, Jose-Maria
    LIFE-BASEL, 2022, 12 (11):