Rapid diagnosis of catheter-related sepsis using the acridine orange leukocyte cytospin test and an endoluminal brush

被引:26
|
作者
Tighe, MJ
Kite, P
Thomas, D
Fawley, WN
McMahon, MJ
机构
[1] UNIV LEEDS,GEN INFIRM,DEPT SURG,DEPT MICROBIOL,LEEDS LS1 3EX,W YORKSHIRE,ENGLAND
[2] UNIV LEEDS,GEN INFIRM,NUTR SUPPORT SERV,LEEDS LS1 3EX,W YORKSHIRE,ENGLAND
关键词
D O I
10.1177/0148607196020003215
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: In neonates, the acridine orange leukocyte cytospin (AOLC) test has been found to be a highly sensitive test for the detection of infected IV catheters in situ, which provides a result in less than 1 hour. Preliminary data suggested that the AOLC test was of limited value in adults. We report here a modification of the test for adult patients with indwelling central venous catheters. Methods: A prospective study was performed on two groups of 50 adult patients with suspected sepsis and a central venous catheter The AOLC test was carried out after the clinical decision to remove the catheter had been made. In group 1 patients, a blood sample was withdrawn from the catheter for the AOLC test. In the patients in group 2, an endoluminal brush was used to ''sweep'' the catheter before the collection of the blood sample. Results of the AOLC test were compared with culture of the removed catheter tip. Results: From the catheters in group 1 (no brush), 17 catheter tips were found to be infected, but the AOLC was positive in only two patients (12%). In group 2 (brush), 18 tips were infected, and the AOLC test was positive in 15 patients (83%). The use of the endoluminal brush significantly improved the yield of the AOLC test (p < .01) to levels reported in neonates. The AOLC test produced no false positives in either group. Conclusion: When used independently, the AOLC test was not sensitive enough to detect catheter-related sepsis. However, in combination with an endoluminal brush, the AOLC test was much more sensitive and has the potential to provide a simple, rapid, and accurate diagnostic test for catheter-related sepsis, which does not require removal of the catheter.
引用
收藏
页码:215 / 218
页数:4
相关论文
共 50 条
  • [1] RAPID DIAGNOSIS OF CATHETER-RELATED SEPSIS USING ACRIDINE-ORANGE LEUKOCYTE CYTOSPIN TEST
    TIGHE, MJ
    KITE, P
    MCMAHON, MJ
    BRITISH JOURNAL OF SURGERY, 1995, 82 (05) : 708 - 708
  • [2] Use of acridine orange leukocyte cytospin test in diagnosis of neonatal sepsis
    Çaksen, H
    Yüksel, S
    Öztürk, MK
    Sümerkan, B
    Çoskun, A
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2001, 37 (05) : 523 - 523
  • [3] Acridine orange leukocyte cytospin test for central venous catheter-related bloodstream infection: A pediatric experience
    Farina, C
    Bonanomi, E
    Benetti, G
    Fumagalli, R
    Goglio, A
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2005, 52 (04) : 337 - 339
  • [4] The use of the FAS Endoluminal Brush in the diagnosis of catheter-related sepsis on the ICU
    Garfield, MJ
    Kent, R
    INTENSIVE CARE MEDICINE, 2002, 28 : S27 - S27
  • [5] Detection of catheter-related bloodstream infections by the Gram stain–acridine orange leukocyte cytospin test in hematopoietic stem cell transplant recipients
    A Abdelkefi
    W Achour
    L Torjman
    T Ben Othman
    S Ladeb
    A Lakhal
    H Allouche
    A Ben Hassen
    A Ben Abdeladhim
    Bone Marrow Transplantation, 2006, 37 : 595 - 599
  • [6] Evaluation of the gram stain-acridine orange leukocyte cytospin test for diagnosis of catheter-related bloodstream infection in children on long-term parenteral nutrition
    A. Ferroni
    K. Moumile
    A. Pasquier
    P. Berche
    V. Colomb
    European Journal of Clinical Microbiology and Infectious Diseases, 2006, 25 : 199 - 201
  • [7] Evaluation of the gram stain-acridine orange leukocyte cytospin test for diagnosis of catheter-related bloodstream infection in children on long-term parenteral nutrition
    Ferroni, A
    Moumile, K
    Pasquier, A
    Berche, P
    Colomb, V
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2006, 25 (03) : 199 - 201
  • [8] Detection of catheter-related bloodstream infections by the Gram stain-acridine orange leukocyte cytospin test in hematopoietic stem cell transplant recipients
    Abdelkefi, A
    Achour, W
    Torjman, L
    Ben Othman, T
    Ladeb, S
    Lakhal, A
    Allouche, H
    Ben Hassen, A
    Ben Abdeladhim, A
    BONE MARROW TRANSPLANTATION, 2006, 37 (06) : 595 - 599
  • [9] RAPID DIAGNOSIS OF INTRAVASCULAR CATHETER-RELATED SEPSIS
    COLLIGNON, P
    CHAN, R
    MUNRO, R
    ARCHIVES OF INTERNAL MEDICINE, 1987, 147 (09) : 1609 - 1612
  • [10] ACRIDINE ORANGE STAINING METHOD IN THE DIAGNOSIS OF CATHETER-RELATED BLOODSTREAM INFECTIONS
    Quintana, R.
    Prieto, M. F.
    Bagilet, D. H.
    Dalman, M. C.
    Gregorini, E.
    MEDICINA INTENSIVA, 2008, 32 (04) : 168 - 171