X-ray diffraction method to identify epithelial to mesenchymal transition in breast cancer tissue

被引:1
|
作者
Alsharif, A. M. [1 ,2 ]
Sani, S. F. Abdul [1 ]
Moradi, F. [1 ]
机构
[1] Univ Malaya, Dept Phys, Kuala Lumpur, Malaysia
[2] Univ Sebha, Dept Phys, Sebha, Libya
来源
INTERNATIONAL NUCLEAR SCIENCE TECHNOLOGY AND ENGINEERING CONFERENCE 2019 (INUSTEC2019) | 2020年 / 785卷
关键词
DIAGNOSIS; IDENTIFICATION; SCATTERING; SYSTEM;
D O I
10.1088/1757-899X/785/1/012044
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Breast Stromal tissue is significantly involved in the spread of cancer because of molecular variations. The main component, collagen, has a spatial arrangement allowing the investigation of its structural patterns in tissues by X-ray diffraction (XRD). Since detection and classification of tumor type and stage from the pathological examinations is a laborious task that additionally does not allow cancer detection in the early stages, development of new tools to improve the diagnostic power of pathologists is still needed. In this study, the potential used of XRD tecniques as one of the method for early detection of breast cancer was done. Four pathological cancerous breast tissue samples were taken from four different patients; where two samples are with epithelial-to-mesenchymal transition (P-EMT) and two samples are without epithelial to mesenchymal transition (N-EMT). The latter was incorporated at an angle interval of 10 to 80 to obtain interference diffraction pattern of XRD of human malignant tissues. This was done to determine molecular structure changes of collagen fiber within the tissue and their potential relation to the changes in cancerous tissue toward metastasis. The results showed that the momentum transfer values for the first region of N-EMT,P-EMT cancerous tissue are not significantly different for both cancerous breast tissue types, being at 1.61 +/- 1.74 nm(-1). The average peaks of the second region were determined for N-EMT at 3.4 +/- 3.5 nm(-1) and P-EMT at 3.6 +/- 3.7 nm(-1) which is attributed to water content of the tissues, due to the greater intensity of the P-EMT compared to that of N-EMT. Principal component analysis (PCA) used to confirm statistical appropriateness of the results, showed a normal distribution within 95% confidence level. P-EMT clusters have a larger number of scatter plots compared to N-EMT, which indicates a higher similarity between P-EMT samples than between N-EMT samples, thus confirming the difference between positive and negative-EMT clusters. The curent analysis can differentiate XRD features and thus confirms its effectiveness in detecting the molecular correlation of abnormal collagen fiber structure within epithelial change, and is useful for early diagnosis even case of dense breasts.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Small angle x-ray scattering and x-ray diffraction of shark mineralized tissue
    Stock, Stuart
    Park, Jun-Sang
    Almer, Jonathan
    James, Kelsey
    Passerotti, Michelle
    Natanson, Lisa
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2022, 78 : A60 - A60
  • [22] X-ray diffraction setup for breast tissue characterization: Experimental validation on beef phantoms
    Feldman, Vera
    Paulus, Caroline
    Tabary, Joachim
    Monnet, Olivier
    Gentet, Marie-Claude
    Hazemann, Jean-Louis
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 972
  • [23] Evaluation of a Low Energy X-Ray Diffraction Imaging System for Breast Tissue Characterization
    Xiao, J.
    Kapadia, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E533 - E533
  • [24] Use of x-ray diffraction to detect changes in hair of women with breast cancer
    Beith, J. M., Sr.
    Corino, G.
    French, P.
    JOURNAL OF CLINICAL ONCOLOGY, 2008, 26 (15)
  • [25] X-ray diffraction studies of transition metal molybdates
    Gawel, B.
    Surga, W.
    Lasocha, W.
    ZEITSCHRIFT FUR KRISTALLOGRAPHIE, 2009, : 381 - 386
  • [26] Displacive Transition Revisited by Coherent X-ray Diffraction
    Ravy, Sylvain
    Le Bolloc'h, David
    Currat, Rolland
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C326 - C326
  • [27] X-RAY DIFFRACTION METHOD OF DETERMINING SUBSTRUCTURE
    PINES, BY
    BADIYAN, EE
    SIRENKO, AF
    SOLNYSHK.DD
    SOVIET PHYSICS CRYSTALLOGRAPHY, USSR, 1967, 12 (03): : 365 - &
  • [28] Tissue-based identification of stem cells and epithelial-to-mesenchymal transition in breast cancer
    Anwar, Talha E.
    Kleer, Celina G.
    HUMAN PATHOLOGY, 2013, 44 (08) : 1457 - 1464
  • [29] STUDIES ON X-RAY ABSORPTION AND DIFFRACTION OF BONE TISSUE
    AMPRINO, R
    ENGSTROM, A
    ACTA ANATOMICA, 1952, 15 (1-2): : 1 - 22
  • [30] X-ray diffraction imaging of cardiac cells and tissue
    Nicolas, Jan-David
    Bernhardt, Marten
    Schlick, Susanne F.
    Tiburcy, Malte
    Zimmermann, Wolfram-Hubertus
    Khan, Amara
    Markus, Andrea
    Alves, Frauke
    Toischer, Karl
    Salditt, Tim
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2019, 144 : 151 - 165