Accurate mass determination, quantification and determination of detection limits in liquid chromatography-high-resolution time-of-flight mass spectrometry: Challenges and practical solutions

被引:25
|
作者
Vergeynst, Leendert [1 ]
Van Langenhove, Herman [1 ]
Joos, Pieter [2 ]
Demeestere, Kristof [1 ]
机构
[1] Univ Ghent, Fac Biosci Engn, Dept Sustainable Organ Chem & Technol, Res Grp Environm Organ Chem & Technol, B-9000 Ghent, Belgium
[2] Antweipse Waterwerken Walem, B-2840 Rumst, Belgium
关键词
High-resolution mass spectrometry; Accurate mass; Mass window width; Validation; Micropollutants; Pharmaceuticals; RESIDUE ANALYSIS; WATER SAMPLES; ORGANIC CONTAMINANTS; DRUG RESIDUES; WASTE-WATER; PHARMACEUTICALS; VALIDATION; SUBSTANCES; PESTICIDES; DECISION;
D O I
10.1016/j.aca.2013.06.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Uniform guidelines for the data processing and validation of qualitative and quantitative multi-residue analysis using full-spectrum high-resolution mass spectrometry are scarce. Through systematic research, optimal mass accuracy and sensitivity are obtained after refining the post-processing of the HRMS data. For qualitative analysis, transforming the raw profile spectra to centroid spectra is recommended resulting in a 2.3 fold improved precision on the accurate mass determination of spectrum peaks. However, processing centroid data for quantitative purposes could lead to signal interruption when too narrow mass windows are applied for the construction of extracted ion chromatograms. Therefore, peak integration on the raw profile data is recommended. An optimal width of the mass window of 50 ppm, which is a trade-off between sensitivity and selectivity, was obtained for a TOF instrument providing a resolving power of 20,000 at full width at half maximum (FWHM). For the validation of HRMS analytical methods, widespread concepts such as the signal-to-noise ratios for the determination of decision limits and detection capabilities have shown to be not always applicable because in some cases almost no noise can be detected anymore. A statistical methodology providing a reliable alternative is extended and applied. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:74 / 82
页数:9
相关论文
共 50 条
  • [31] Identification and Determination of Nonionic Surfactants by Ultrahigh-Performance Liquid Chromatography-High-Resolution Mass Spectrometry
    Amelin, V. G.
    Bol'shakov, D. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 76 (02) : 226 - 242
  • [32] Simple and sensitive determination of α- and β-amanitin by liquid chromatography-quadrupole time-of-flight mass spectrometry
    Ishii, Akira
    Tada, Miho
    Kusano, Maiko
    Ogawa, Tadashi
    Hattori, Hideki
    Seno, Hiroshi
    Zaitsu, Kei
    FORENSIC TOXICOLOGY, 2014, 32 (02) : 342 - 346
  • [33] Simultaneous Determination of Slimming Drugs in Dietary Supplements by Liquid Chromatography/Time-of-Flight Mass Spectrometry
    Saito, Koichi
    Yato, Masakadzu
    Kobayashi, Yoshiyuki
    Ito, Rie
    CHROMATOGRAPHY, 2019, 40 (01) : 19 - 24
  • [34] Enantioselective Determination of Synephrine in Health Food Products by Liquid Chromatography/Time-of-Flight Mass Spectrometry
    Kobayashi, Yoshiyuki
    Yato, Masakadzu
    Ito, Rie
    Saito, Koichi
    CHROMATOGRAPHY, 2020, 41 (01) : 39 - 44
  • [35] A simple method for the simultaneous determination of mushroom toxins by liquid chromatography–time-of-flight mass spectrometry
    Naoki Yoshioka
    Shigeki Akamatsu
    Takao Mitsuhashi
    Chikage Todo
    Migiwa Asano
    Yasuhiro Ueno
    Forensic Toxicology, 2014, 32 : 89 - 96
  • [36] Potential of liquid chromatography/time-of-flight mass spectrometry for the determination of pesticides and transformation products in water
    Juan V. Sancho
    Óscar J. Pozo
    María Ibáñez
    Félix Hernández
    Analytical and Bioanalytical Chemistry, 2006, 386
  • [37] Identification and determination of structurally related peptide impurities in thymalfasin by liquid chromatography-high-resolution mass spectrometry
    Yuya Cheng
    Peize Wu
    Ying Kan
    Ming Li
    Hongmei Li
    Analytical and Bioanalytical Chemistry, 2022, 414 : 8035 - 8045
  • [38] Quantitative liquid chromatography/time-of-flight mass spectrometry
    Williamson, Leah N.
    Bartlett, Michael G.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) : 567 - 576
  • [39] Determination of the accurate mass of erythromycin analogue antibiotic by electrospray ionization/time-of-flight mass spectrometry
    Hu, SG
    Guo, YL
    Lü, L
    ACTA CHIMICA SINICA, 2000, 58 (11) : 1452 - 1456
  • [40] Free Fatty Acid Determination in Broccoli Tissues Using Liquid Chromatography-High-Resolution Mass Spectrometry
    Mantzourani, Christiana
    Mesimeri, Irene-Dimitra
    Kokotou, Maroula G.
    MOLECULES, 2024, 29 (04):