Influence of loading condition and anatomical location on human cortical bone linear micro-cracks

被引:9
|
作者
Gauthier, Remy [1 ,2 ]
Langer, Max [2 ]
Follet, Helene [3 ]
Olivier, Cecile [2 ,4 ]
Gouttenoire, Pierre-Jean [2 ,4 ]
Helfen, Lukas [4 ,6 ]
Rongieras, Frederic [1 ,5 ]
Mitton, David [1 ]
Peyrin, Francoise [2 ,4 ]
机构
[1] Univ Claude Bernard Lyon 1, IFSTTAR, LBMC UMR T9406, Univ Lyon, F-69622 Lyon, France
[2] Univ Claude Bernard Lyon 1, CNRS UMR 5220, Inserm U1206, INSA Lyon,Univ Lyon, F-69621 Villeurbanne, France
[3] Univ Claude Bernard Lyon 1, INSERM, LYOS UMR1033, Univ Lyon, Lyon, France
[4] European Synchrotron Radiat Facil, CS 40220, F-38043 Grenoble 9, France
[5] Hop Desgenettes, Serv Chirurg Orthoped & Traumatol, F-69003 Lyon, France
[6] Karlsruhe Inst Technol, Inst Photon Sci & Synchrotron Radiat, D-76131 Karlsruhe, Germany
关键词
Human cortical bone; Inter-site; Strain rate; Micro-cracks; Synchrotron radiation; Computed tomography; STRAIN-RATE; NONENZYMATIC GLYCATION; DAMAGE MORPHOLOGY; MICRODAMAGE; TOUGHNESS; FRACTURE; MICROCRACKS; PROPAGATION; MECHANISMS; STRENGTH;
D O I
10.1016/j.jbiomech.2019.01.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Human cortical bone fracture toughness depends on the anatomical locations under quasi-static loading. Recent results also showed that under fall-like loading, cortical bone fracture toughness is similar at different anatomical locations in the same donor. While cortical bone toughening mechanisms are known to be dependent on the tissue architecture under quasi-static loading, the fracture mechanisms during a fall are less studied. In the current study, the structural parameters of eight paired femoral diaphyses, femoral necks and radial diaphyses were mechanically tested under quasi-static and fall-like loading conditions (female donors, 70 +/- 14 y.o., [50-91 y.o.]). Synchrotron radiation micro-CT imaging was used to quantify the amount of micro-cracks formed during loading. The volume fraction of these micro-cracks was significantly higher within the specimens loaded under a quasi-static condition than under a loading representative of a fall. Under fall-like loading, there was no difference in crack volume fraction between the different paired anatomical locations. This result shows that the micro-cracking toughening mechanism depends both on the anatomical location and on the loading condition. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [21] Investigation of the influence of a multi-axial state of stress on the behaviour of intercrystalline creep micro-cracks
    Freres, P
    ElMagd, E
    COMPUTATIONAL MATERIALS SCIENCE, 1996, 5 (1-3) : 101 - 110
  • [22] Influence of the Multi-segment Micro-crack and Groups of Kinked Micro-cracks on the Plastic Behavior of a Macro-crack
    Yang, Hongda
    Zhang, Jiding
    Ma, Wentao
    Jiang, Xiaoyu
    ACTA MECHANICA SOLIDA SINICA, 2025,
  • [23] Study on meso-deformation and failure mechanism of rock mass with micro-cracks under freeze-thaw loading
    Qiu, Liewang
    Shi, Chong
    Zhang, Lingkai
    Zhang, Fuhai
    SIMULATION MODELLING PRACTICE AND THEORY, 2024, 135
  • [24] Toughness of Human Cortical Bone Measured with Realistically Short Cracks
    Sirinrath Sirivisoot
    MRS Bulletin, 2008, 33 : 900 - 900
  • [25] Toughness of Human Cortical Bone Measured with Realistically Short Cracks
    Sirivisoot, Sirinrath
    MRS BULLETIN, 2008, 33 (10) : 900 - 900
  • [26] Fatigue crack propagation and threshold for shallow micro-cracks under out-of-phase multiaxial loading in a gear steel
    Beretta, S.
    Foletti, S.
    Valiullin, K.
    ENGINEERING FRACTURE MECHANICS, 2010, 77 (11) : 1835 - 1848
  • [27] Strain rate influence on human cortical bone toughness: A comparative study of four paired anatomical sites
    Gauthier, Remy
    Follet, Helene
    Langer, Max
    Meille, Sylvain
    Chevalier, Jerome
    Rongieras, Frederic
    Peyrin, Francoise
    Mitton, David
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 71 : 223 - 230
  • [28] Cortical Bone Microstructure and Strength at the Mid-Diaphysis of Human Femurs: Influence of the Anatomical Position.
    Beaupied, H.
    Basillais, A.
    Lepissier, J.
    Hambli, R.
    Soulat, D.
    Chappard, C.
    Dolleans, E.
    Benhamou, C.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 : S416 - S416
  • [29] MICRO-MECHANICAL CHARACTERISATION OF HUMAN CORTICAL BONE
    Jonvaux, Julien
    Budyn, Elisa
    Hoc, Thierry
    NEMB2010: PROCEEDINGS OF THE ASME FIRST GLOBAL CONGRESS ON NANOENGINEERING FOR MEDICINE AND BIOLOGY - 2010, 2010, : 321 - 323
  • [30] The true toughness of human cortical bone measured with realistically short cracks
    K. J. Koester
    J. W. Ager
    R. O. Ritchie
    Nature Materials, 2008, 7 : 672 - 677