A method for proving the global stability of a synchronous generator connected to an infinite bus

被引:0
|
作者
Natarajan, Vivek [1 ]
Weiss, George [1 ]
机构
[1] Tel Aviv Univ, Sch Elect Engn, IL-69978 Tel Aviv, Israel
关键词
SYNCHRONVERTERS INVERTERS;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
We consider a grid connected synchronous generator (SG), having a constant field current and driven by a prime mover with constant torque. The grid is regarded as an "infinite bus", i.e., a three-phase AC voltage source. The problem of interest is verifying if, for a given set of SG parameters, the angular velocity of the SG rotor converges to the angular velocity of the grid, irrespectively of the SG initial conditions. We pose this problem as a question of almost global asymptotic stability of a fourth order nonlinear system. In a recent work, we derived an integro-differential equation, which resembles the forced pendulum equation, and showed that the fourth order system is almost globally asymptotically stable if and only if the same holds for this equation. In this paper, it is shown that this equation is almost globally asymptotically stable if a real-valued nonlinear map defined on a finite interval is a contraction. For any given set of SG parameters, it is straight forward to check numerically if this map is a contraction. An example demonstrating our results is included.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] STEADY-STATE STABILITY LIMITS OF A REGULATED SYNCHRONOUS MACHINE CONNECTED TO AN INFINITE SYSTEM
    YU, YN
    VONGSURIYA, K
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1966, PA85 (07): : 759 - +
  • [32] DYNAMIC STABILITY OF PARALLEL CONNECTED SYNCHRONOUS GENERATORS BY THE EIGENVALUE METHOD
    ELKHARASHI, AK
    SALEM, SR
    BADR, MAL
    ELECTRIC MACHINES AND POWER SYSTEMS, 1989, 16 (06): : 379 - 394
  • [33] Large Signal Stability Analysis of a DC/AC Droop Controlled Inverter Connected to an Infinite Bus
    Kabalan, Mahmoud
    Singh, Pritpal
    Niebur, Dagmar
    2015 NORTH AMERICAN POWER SYMPOSIUM (NAPS), 2015,
  • [34] Lyapunov stability of grid-connected wind turbines with permanent magnet synchronous generator
    Nguyen, Phuong T. H.
    Studli, Sonja
    Braslavsky, Julio H.
    Middleton, Richard H.
    EUROPEAN JOURNAL OF CONTROL, 2022, 65
  • [35] Sequence Impedance Modeling and Stability Analysis for Virtual Synchronous Generator Connected to the Weak Grid
    Wu W.
    Chen Y.
    Zhou L.
    Luo A.
    Zhou X.
    Huang X.
    Yang L.
    Xie Z.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (06): : 1560 - 1571
  • [36] Virtual Synchronous Generator Grid Connected Control Method Based on Virtual Impedance
    Shao, Bao-zhu
    Zhang, Guan-feng
    Yang, Jun-you
    Gao, Fei-fei
    Sun, Feng
    Zhao, Qing-song
    2018 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS AND CONTROL ENGINEERING (ISPECE 2018), 2019, 1187
  • [37] Effect of Extended State Observer and Automatic Voltage Regulator on Synchronous Machine Connected to Infinite Bus Power System
    Angu R.
    Mehta R.K.
    Angu, Rittu (rituangu14@gmail.com), 2018, Springer (99) : 147 - 156
  • [38] Control of a hybrid excitation synchronous generator connected to a diode bridge rectifier supplying a DC bus in embedded applications
    Mbayed, Rita
    Salloum, Georges
    Vido, Lionel
    Monmasson, Eric
    Gabsi, Mohamed
    IET ELECTRIC POWER APPLICATIONS, 2013, 7 (01) : 68 - 76
  • [39] On controlling a HVDC scheme connected with a synchronous generator
    Teppoz, L
    Bornard, G
    Besançon, G
    PROCEEDINGS OF THE 23RD IASTED INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION, AND CONTROL, 2004, : 392 - 397
  • [40] EXPERIMENTAL STUDY ON THE STEADY-STATE STABILITY OF THE TWO MACHINES CONNECTED TO AN INFINITE BUS SYSTEM.
    Matsuki, Junya
    Harada, Masahiro
    Matsumoto, Yoshinaga
    Okada, Takao
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1985, 105 (03): : 89 - 95