Uricase Crowding via Polyelectrolyte Layers Coacervation for Carbon Fiber-Based Electrochemical Detection of Uric Acid

被引:4
|
作者
Baldina, Anna A. [1 ]
Pershina, Liubov V. [1 ]
Noskova, Ulyana V. [1 ]
Nikitina, Anna A. [1 ]
Muravev, Anton A. [1 ]
Skorb, Ekaterina V. [1 ]
Nikolaev, Konstantin G. [1 ]
机构
[1] ITMO Univ, Infochem Sci Ctr, St Petersburg 191002, Russia
基金
俄罗斯科学基金会;
关键词
layer-by-layer assembly; polyelectrolyte; crowding effect; uric acid; SARS-CoV-2; WEAK POLYELECTROLYTES; PRUSSIAN BLUE; BIOSENSOR; HYDROGEL; ENZYME;
D O I
10.3390/polym14235145
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Urate oxidase (UOx) surrounded by synthetic macromolecules, such as polyethyleneimine (PEI), poly(allylamine hydrochloride) (PAH), and poly(sodium 4-styrenesulfonate) (PSS) is a convenient model of redox-active biomacromolecules in a crowded environment and could display high enzymatic activity towards uric acid, an important marker of COVID-19 patients. In this work, the carbon fiber electrode was modified with Prussian blue (PB) redox mediator, UOx layer, and a layer-by-layer assembled polyelectrolyte film, which forms a complex coacervate consisting of a weakly charged polyelectrolyte (PEI or PAH) and a highly charged one (PSS). The film deposition process was controlled by cyclic voltammetry and scanning electron microscopy coupled with energy-dispersive X-ray analysis (at the stage of PB deposition) and through quartz crystal microbalance technique (at latter stages) revealed uniform distribution of the polyelectrolyte layers. Variation of the polyelectrolyte film composition derived the following statements. (1) There is a linear correlation between electrochemical signal and concentration of uric acid in the range of 10(-4)-10(-6) M. (2) An increase in the number of polyelectrolyte layers provides more reproducible values for uric acid concentration in real urine samples of SARS-CoV-2 patients measured by electrochemical enzyme assay, which are comparable to those of spectrophotometric assay. (3) The PAH/UOx/PSS/(PAH/PSS)(2)-coated carbon fiber electrode displays the highest sensitivity towards uric acid. (4) There is a high enzyme activity of UOx immobilized into the hydrogel nanolayer (values of the Michaelis-Menten constant are up to 2 mu M) and, consequently, high affinity to uric acid.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Covalent modification of multiwall carbon nanotubes with β-cyclodextrin for enhanced electrochemical detection of uric acid
    Gillespie, Samuel
    Schwarzmann, Margaret
    Kane, Alexander
    Bowles, Christopher
    Trawick, Matthew
    Wayu, Mulugeta
    Leopold, Michael
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [42] Multiwalled carbon nanotubes supported Fe nanostructured interfaces for electrochemical detection of uric acid
    Joshi, Anju
    Slaughter, Gymama
    MICROCHEMICAL JOURNAL, 2024, 204
  • [43] Electrochemical Selective Detection of Uric Acid Using a Copper-modified Carbon Electrode
    Sakamoto, Hiroaki
    Hatsuda, Ranko
    Miyamura, Kazuhiro
    Shiraishi, Haruki
    Sugiyama, Susumu
    ANALYTICAL SCIENCES, 2011, 27 (03) : 333 - 335
  • [44] Electrochemical detection of uric acid using graphite screen-printed electrodes modified with Prussian blue/poly(4-aminosalicylic acid)/Uricase
    da Cruz, Filipe Soares
    Paula, Fernanda de Souza
    Franco, Diego Leoni
    Pio dos Santo, Wallans Torres
    Ferreira, Lucas Franco
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 806 : 172 - 179
  • [45] Highly Selective Electrochemical Sensing of Dopamine, Xanthine, Ascorbic Acid and Uric Acid Using a Carbon Fiber Paper
    Mohan, Jaligam Murali
    Amreen, Khairunnisa
    Javed, Arshad
    Dubey, Satish Kumar
    Goel, Sanket
    IEEE SENSORS JOURNAL, 2020, 20 (19) : 11707 - 11712
  • [46] An Amperomertic Uric Acid Biosensor Based on Immobilization of Uricase onto Polyaniline-multiwalled Carbon Nanotube Composite Film
    Bhambi, Manu
    Sumana, G.
    Malhotra, B. D.
    Pundir, C. S.
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2010, 38 (04): : 178 - 185
  • [47] Layer-by-layer assembly of composite conductive fiber-based organic electrochemical transistor for highly sensitive detection of sialic acid
    Zhu, Rufeng
    Wang, Yuedan
    Tao, Yang
    Wang, Yao
    Chen, Yuanli
    Li, Mufang
    Liu, Qiongzhen
    Yang, Liyan
    Wang, Dong
    ELECTROCHIMICA ACTA, 2022, 425
  • [48] Electrochemical Sensor Based on Carbon-Incorporated WSe2 Nanosheets for Simultaneous Detection of Ascorbic Acid, Dopamine, and Uric Acid
    Cogal, Sadik
    Bhethanabotla, Venkat R.
    IEEE SENSORS JOURNAL, 2022, 22 (15) : 14952 - 14958
  • [49] A Novel Electrochemical Sensor Based on Pd Confined Mesoporous Carbon Hollow Nanospheres for the Sensitive Detection of Ascorbic Acid, Dopamine, and Uric Acid
    Zhang, Wanqing
    Li, Xijiao
    Liu, Xiaoxue
    Song, Kaixuan
    Wang, Haiyang
    Wang, Jichao
    Li, Renlong
    Liu, Shanqin
    Peng, Zhikun
    MOLECULES, 2024, 29 (11):
  • [50] Non-Enzymatic Electrochemical Detection for Uric Acid Based on a Glassy Carbon Electrode Modified With MOF-71
    Abrori, Syauqi Abdurrahman
    Septiani, Ni Luh Wulan
    Hakim, Fahmi Nur
    Maulana, Angga
    Suyatman
    Nugraha
    Anshori, Isa
    Yuliarto, Brian
    IEEE SENSORS JOURNAL, 2021, 21 (01) : 170 - 177