Dosimetric effect of intrafraction tumor motion in phase gated lung stereotactic body radiotherapy

被引:30
|
作者
Zhao, Bo [1 ,2 ]
Yang, Yong [1 ]
Li, Tianfang [1 ]
Li, Xiang [1 ]
Heron, Dwight E. [1 ]
Huq, M. Saiful [1 ]
机构
[1] Univ Pittsburgh, Inst Canc, Dept Radiat Oncol, Pittsburgh, PA 15232 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
关键词
tumor motion; gated treatment; SBRT; DMLC; interplay; FRACTION ORGAN MOTION; RESPIRATORY MOTION; STATISTICAL-ANALYSIS; RADIATION-THERAPY; IMRT; DELIVERY;
D O I
10.1118/1.4757916
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A major concern for lung intensity modulated radiation therapy delivery is the deviation of actually delivered dose distribution from the planned one due to simultaneous movements of multileaf collimator (MLC) leaves and tumor. For gated lung stereotactic body radiotherapy treatment (SBRT), the situation becomes even more complicated because of SBRT's characteristics such as fewer fractions, smaller target volume, higher dose rate, and extended fractional treatment time. The purpose of this work is to investigate the dosimetric effect of intrafraction tumor motion during gated lung SBRT delivery by reconstructing the delivered dose distribution with real-time tumor motion considered. Methods: The tumor motion data were retrieved from six lung patients. Each of them received three fractions of stereotactic radiotherapy treatments with Cyberknife Synchrony (Accuray, Sunnyvale, CA). Phase gating through an external surrogate was simulated with a gating window of 5 mm. The resulting residual tumor motion curves during gating (beam-on) were retrieved. Planning target volume (PTV) was defined as physician-contoured clinical target volume (CTV) surrounded by an isotropic 5 mm margin. Each patient was prescribed with 60 Gy/3 fractions. The authors developed an algorithm to reconstruct the delivered dose with tumor motion. The DMLC segments, mainly leaf position and segment weighting factor, were recalculated according to the probability density function of tumor motion curve. The new DMLC sequence file was imported back to treatment planning system to reconstruct the dose distribution. Results: Half of the patients in the study group experienced PTV D95% deviation up to 26% for fractional dose and 14% for total dose. CTV mean dose dropped by 1% with tumor motion. Although CTV is almost covered by prescribed dose with 5 mm margin, qualitative comparison on the dose distributions reveals that CTV is on the verge of underdose. The discrepancy happens due to tumor excursion outside of the gating window, which, for our study group, is mainly caused by baseline shift, i.e., the change in general trend of the motion curve during extended period of treatment time. Conclusions: The dose deviation in PTV and CTV due to target motion is not always negligible in gated SBRT. Although CTVs are covered sufficiently with prescribed dose in most cases, some are on the verge of underdose due to large tumor excursion caused by factors such as baseline shift. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4757916]
引用
收藏
页码:6629 / 6637
页数:9
相关论文
共 50 条
  • [41] Frameless high dose rate stereotactic lung radiotherapy: Intrafraction tumor position and delivery time
    Peguret, Nicolas
    Dahele, Max
    Cuijpers, Johan P.
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    RADIOTHERAPY AND ONCOLOGY, 2013, 107 (03) : 419 - 422
  • [42] Impact of Immobilization on Intrafraction Motion for Spine Stereotactic Body Radiotherapy Using Cone Beam Computed Tomography
    Li, Winnie
    Sahgal, Arjun
    Foote, Matthew
    Millar, Barbara-Ann
    Jaffray, David A.
    Letourneau, Daniel
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (02): : 520 - 526
  • [43] Single-fraction prostate stereotactic body radiotherapy: Dose reconstruction with electromagnetic intrafraction motion tracking
    Jaccard, Maud
    Ehrbar, Stefanie
    Miralbell, Raymond
    Hagen, Tobias
    Koutsouvelis, Nikolaos
    Poulsen, Per
    Rouzaud, Michel
    Tanadini-Lang, Stephanie
    Tsoutsou, Pelagia
    Guckenberger, Matthias
    Zilli, Thomas
    RADIOTHERAPY AND ONCOLOGY, 2021, 156 : 145 - 152
  • [44] Extensive evaluation of dosimetric robustness for respiratory motion of lung tumor radiotherapy
    Olofsson, N.
    Wikstrom, K.
    Flejmer, A.
    Ahnesjo, A.
    Dasu, A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S416 - S417
  • [45] Dosimetric influence of tumor motion for different types of lung stereotactic treatment planning
    Perez, V. Gonzalez
    Contreras, V. Crispin
    Mocholi, D. Abad
    Salido, A. Bartres
    Alemany, V. De Los Dolores
    De la Flor, C. Guardino
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S192 - S193
  • [46] Impact of lung tumor motion on dosimetric consequences of helical tomotherapy stereotactic plans
    Mahalleh, Ebrahimi Tazeh F.
    Moustakis, C.
    Haverkamp, U.
    Eich, H. T.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S80 - S80
  • [47] Dosimetric effect of respiratory motion in external beam radiotherapy of the lung
    Mechalakos, J
    Yorke, E
    Mageras, GS
    Hertanto, A
    Jackson, A
    Obcemea, C
    Rosenzweig, K
    Ling, CC
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 (02) : 191 - 200
  • [48] INTERFRACTION AND INTRAFRACTION CHANGES IN AMPLITUDE OF BREATHING MOTION IN STEREOTACTIC LIVER RADIOTHERAPY
    Case, Robert B.
    Moseley, Douglas J.
    Sonke, Jan Jakob
    Eccles, Cynthia L.
    Dinniwell, Robert E.
    Kim, John
    Bezjak, Andrea
    Milosevic, Michael
    Brock, Kristy K.
    Dawson, Laura A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (03): : 918 - 925
  • [49] Dosimetric Effect of Irregular Respiratory Motion on Radiotherapy of Lung Tumors
    Mutaf, Y. D.
    Scicutella, C. J.
    Michalski, D.
    Brandner, E. D.
    Fallon, K.
    Bednarz, G.
    Huq, S. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S607 - S607
  • [50] Dosimetric Impact of Breathing Motion in Lung Stereotactic Body Radiotherapy Treatment Using Image-Modulated Radiotherapy and Volumetric Modulated Arc Therapy
    Rao, Min
    Wu, Jianzhou
    Cao, Daliang
    Wong, Tony
    Mehta, Vivek
    Shepard, David
    Ye, Jinsong
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (02): : E251 - E256