Differences in long-term fixation between mobile-bearing and fixed-bearing knee prostheses at ten to 12 years' follow-up A SINGLE-BLINDED RANDOMISED CONTROLLED RADIOSTEREOMETRIC TRIAL

被引:32
|
作者
Pijls, B. G. [1 ]
Valstar, E. R. [1 ]
Kaptein, B. L. [1 ]
Nelissen, R. G. H. H. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Orthopaed, NL-2300 RC Leiden, Netherlands
来源
关键词
ARTHROPLASTY; METAANALYSIS; OUTCOMES; QUALITY; RSA;
D O I
10.1302/0301-620X.94B10.28858
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This single-blinded randomised controlled trial investigated whether one design of mobile-bearing (MB) total knee replacement (TKR) has any advantage over a fixed-bearing (FB) design on long-term fixation as measured by radiostereometry. The amount of wear underneath the mobile bearing was also evaluated. A series of 42 knees was randomised to MB or FB tibial components with appropriate polyethylene inserts and followed for between ten and 12 years, or until the death of the patient. The polyethylene in the MB group was superior in that it was gamma-irradiated in inert gas and was calcium-stearate free; the polyethylene in the FB group was gamma-irradiated in air and contained calcium stearate. In theory this should be advantageous to the wear rate of the MB group. At final follow-up the overall mean migration was 0.75 mm (SD 0.76) in the MB group and 0.66 mm (SD 0.4) in the FB group, with the FB group demonstrating more posterior tilt and the MB group more internal rotation. In the FB group there was one revision for aseptic loosening, but none in the MB group. There were no significant differences in clinical or radiological scores. For the MB group, the mean linear wear rate on the under-surface was 0.026 mm/year (SD 0.014). This was significantly smaller than the wear rate of 0.11 mm/year (SD 0.06) in the MB between femur and polyethylene (p < 0.001). Nevertheless, even in a best-case setting the mobile bearings of this TKR design had no apparent advantage in terms of fixation over the FB knee prosthesis at ten to 12 years. The wear underneath the mobile bearing was small and is unlikely to be clinically relevant.
引用
收藏
页码:1366 / 1371
页数:6
相关论文
共 50 条
  • [41] Long-Term Functional Outcomes and Quality of Life at Minimum 10-Year Follow-Up After Fixed-Bearing Unicompartmental Knee Arthroplasty and Total Knee Arthroplasty for Isolated Medial Compartment Osteoarthritis
    Tan, Marcus Wei Ping
    Ng, Stacy Wei Ling
    Chen, Jerry Yongqiang
    Liow, Ming Han Lincoln
    Lo, Ngai Nung
    Yeo, Seng Jin
    JOURNAL OF ARTHROPLASTY, 2021, 36 (04): : 1269 - 1276
  • [42] No clinical difference between TiN-coated versus uncoated cementless CoCrMo mobile-bearing total knee arthroplasty; 10-year follow-up of a randomized controlled trial
    Louwerens, Jan K. G.
    Hockers, Niels
    Achten, Gijs
    Sierevelt, Inger N.
    Nolte, Peter A.
    van Hove, Ruud P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2021, 29 (03) : 750 - 756
  • [43] No clinical difference between TiN-coated versus uncoated cementless CoCrMo mobile-bearing total knee arthroplasty; 10-year follow-up of a randomized controlled trial
    Jan K. G. Louwerens
    Niels Hockers
    Gijs Achten
    Inger N. Sierevelt
    Peter A. Nolte
    Ruud P. van Hove
    Knee Surgery, Sports Traumatology, Arthroscopy, 2021, 29 : 750 - 756
  • [44] Clinical and Anatomical Outcomes of Arthroscopic Repair of Large Rotator Cuff Tears with Allograft Patch Augmentation: A Prospective, Single-Blinded, Randomized Controlled Trial with a Long-term Follow-up
    Lee, Geun Woo
    Kim, Jung Youn
    Lee, Ho Won
    Yoon, Joon Hyeok
    Noh, Kyu-Cheol
    CLINICS IN ORTHOPEDIC SURGERY, 2022, 14 (02) : 263 - 271
  • [45] No difference in long-term outcomes between men and women undergoing medial fixed-bearing cemented unicompartmental knee arthroplasty: A retrospective cohort study with minimum 10-year follow up
    Goh, Graham S.
    Zeng, Gerald Joseph
    Khow, Yong Zhi
    Lo, Ngai-Nung
    Yeo, Seng-Jin
    Liow, Ming Han Lincoln
    KNEE, 2021, 30 : 26 - 34
  • [46] Long-term follow-up of replacement compared with internal fixation for displaced femoral neck fractures RESULTS AT TEN YEARS IN A RANDOMISED STUDY OF 450 PATIENTS
    Leonardsson, O.
    Sernbo, I.
    Carlsson, A.
    Akesson, K.
    Rogmark, C.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (03): : 406 - 412
  • [47] Long-term effects of medical exercise therapy inpatients with patellofemoral pain syndrome: Results from a single-blinded randomized controlled trial with 12 months follow-up (vol 99, pg 311, 2013)
    Osteras, Berit
    Osteras, Havard
    Torstensen, Tom Arild
    PHYSIOTHERAPY, 2014, 100 (01) : E1 - E1
  • [48] No clinical difference at mid-term follow-up between TiN-coated versus uncoated cemented mobile-bearing total knee arthroplasty: a matched cohort study
    Deroche, Etienne
    Batailler, Cecile
    Shatrov, Jobe
    Gunst, Stanislas
    Servien, Elvire
    Lustig, Sebastien
    SICOT-J, 2023, 9 : 335 - 340
  • [49] Mid-term clinical and radiological results do not differ between fixed- and mobile-bearing total knee arthroplasty using titanium-nitride-coated posterior-stabilized prostheses: a prospective randomized controlled trial
    Park, Cheol Hee
    Kang, Se Gu
    Bae, Dae Kyung
    Song, Sang Jun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1165 - 1173
  • [50] Mid-term clinical and radiological results do not differ between fixed- and mobile-bearing total knee arthroplasty using titanium-nitride-coated posterior-stabilized prostheses: a prospective randomized controlled trial
    Cheol Hee Park
    Se Gu Kang
    Dae Kyung Bae
    Sang Jun Song
    Knee Surgery, Sports Traumatology, Arthroscopy, 2019, 27 : 1165 - 1173