Diagnostic Performance of Noninvasive Myocardial Perfusion Imaging Using Single-Photon Emission Computed Tomography, Cardiac Magnetic Resonance, and Positron Emission Tomography Imaging for the Detection of Obstructive Coronary Artery Disease A Meta-Analysis

被引:324
|
作者
Jaarsma, Caroline [1 ,2 ,3 ]
Leiner, Tim [2 ,3 ]
Bekkers, Sebastiaan C. [1 ,3 ]
Crijns, Harry J. [1 ,3 ]
Wildberger, Joachim E. [2 ,3 ]
Nagel, Eike [5 ]
Nelemans, Patricia J. [3 ,4 ]
Schalla, Simon [1 ,3 ]
机构
[1] Maastricht Univ Med Ctr, Dept Cardiol, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ Med Ctr, Dept Radiol, NL-6202 AZ Maastricht, Netherlands
[3] Maastricht Univ Med Ctr, Cardiovasc Res Inst Maastricht, NL-6202 AZ Maastricht, Netherlands
[4] Maastricht Univ Med Ctr, Dept Epidemiol, NL-6202 AZ Maastricht, Netherlands
[5] Kings Coll London, Div Imaging Sci, London WC2R 2LS, England
关键词
cardiovascular magnetic resonance imaging; meta-analysis; perfusion; positron emission tomography; single-photon emission computed tomography; PROGNOSTIC VALUE; ATTENUATION CORRECTION; EXERCISE ECHOCARDIOGRAPHY; STRESS PERFUSION; LOW LIKELIHOOD; FLOW RESERVE; ANGIOGRAPHY; PROGRESSION; GUIDELINES; INFARCTION;
D O I
10.1016/j.jacc.2011.12.040
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives This study aimed to determine the diagnostic accuracy of the 3 most commonly used noninvasive myocardial perfusion imaging modalities, single-photon emission computed tomography (SPECT), cardiac magnetic resonance (CMR), and positron emission tomography (PET) perfusion imaging for the diagnosis of obstructive coronary artery disease (CAD). Additionally, the effect of test and study characteristics was explored. Background Accurate detection of obstructive CAD is important for effective therapy. Noninvasive myocardial perfusion imaging is increasingly being applied to gauge the severity of CAD. Methods Studies published between 1990 and 2010 identified by PubMed search and citation tracking were examined. A study was included if a perfusion imaging modality was used as a diagnostic test for the detection of obstructive CAD and coronary angiography as the reference standard (>= 50% diameter stenosis). Results Of the 3,635 citations, 166 articles (n = 17,901) met the inclusion criteria: 114 SPECT, 37 CMR, and 15 PET articles. There were not enough publications on other perfusion techniques such as perfusion echocardiography and computed tomography to include these modalities into the study. The patient-based analysis per imaging modality demonstrated a pooled sensitivity of 88% (95% confidence interval [CI]: 88% to 89%), 89% (95% CI: 88% to 91%), and 84% (95% CI: 81% to 87%) for SPECT, CMR, and PET, respectively; with a pooled specificity of 61% (95% CI: 59% to 62%), 76% (95% CI: 73% to 78%), and 81% (95% CI: 74% to 87%). This resulted in a pooled diagnostic odds ratio (DOR) of 15.31 (95% CI: 12.66 to 18.52; I-2 63.6%), 26.42 (95% CI: 17.69 to 39.47; I-2 58.3%), and 36.47 (95% CI: 21.48 to 61.92; I-2 0%). Most of the evaluated test and study characteristics did not affect the ranking of diagnostic performances. Conclusions SPECT, CMR, and PET all yielded a high sensitivity, while a broad range of specificity was observed. SPECT is widely available and most extensively validated; PET achieved the highest diagnostic performance; CMR may provide an alternative without ionizing radiation and a similar diagnostic accuracy as PET. We suggest that referring physicians consider these findings in the context of local expertise and infrastructure. (J Am Coll Cardiol 2012;59:1719-28) (C) 2012 by the American College of Cardiology Foundation
引用
下载
收藏
页码:1719 / 1728
页数:10
相关论文
共 50 条
  • [21] Imaging discrepancies between magnetic resonance imaging and brain perfusion single-photon emission computed tomography in the diagnosis of Alzheimer's disease, and verification with amyloid positron emission tomography
    Yokoyama, Shunichi
    Kajiya, Yoriko
    Yoshinaga, Takuma
    Tani, Atsushi
    Hirano, Hirofumi
    PSYCHOGERIATRICS, 2014, 14 (02) : 110 - 117
  • [22] Myocardial Blood Flow Quantification for Evaluation of Coronary Artery Disease by Positron Emission Tomography, Cardiac Magnetic Resonance Imaging, and Computed Tomography
    Waller, Alfonso H.
    Blankstein, Ron
    Kwong, Raymond Y.
    Di Carli, Marcelo F.
    CURRENT CARDIOLOGY REPORTS, 2014, 16 (05)
  • [23] Myocardial Blood Flow Quantification for Evaluation of Coronary Artery Disease by Positron Emission Tomography, Cardiac Magnetic Resonance Imaging, and Computed Tomography
    Alfonso H. Waller
    Ron Blankstein
    Raymond Y. Kwong
    Marcelo F. Di Carli
    Current Cardiology Reports, 2014, 16
  • [24] Assessment of myocardial viability using single-photon emission computed tomography myocardial perfusion imaging
    Malhotra, Saurabh
    Gomez, Javier
    Doukky, Rami
    CURRENT OPINION IN CARDIOLOGY, 2019, 34 (05) : 473 - 483
  • [25] Magnetic resonance imaging, positron emission tomography, and single-photon-emission computed tomography in epilepsy
    Chong, BW
    Shelton, DK
    WESTERN JOURNAL OF MEDICINE, 1996, 165 (1-2): : 53 - 54
  • [26] Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography
    Tanabe, Yuki
    Kido, Teruhito
    Uetani, Teruyoshi
    Kurata, Akira
    Kono, Tamami
    Ogimoto, Akiyoshi
    Miyagawa, Masao
    Soma, Tsutomu
    Murase, Kenya
    Iwaki, Hirotaka
    Mochizuki, Teruhito
    EUROPEAN RADIOLOGY, 2016, 26 (11) : 3790 - 3801
  • [27] Magnetic resonance imaging in determination of myocardial ischemia and viability: Comparison with positron emission tomography and single-photon emission computed tomography in a porcine model
    Wang, L.
    Zhu, H. Y.
    Tian, J. M.
    Huang, S. D.
    Kong, L. S.
    Lu, J. P.
    ACTA RADIOLOGICA, 2007, 48 (05) : 500 - 507
  • [28] Differentiation of myocardial ischemia and infarction assessed by dynamic computed tomography perfusion imaging and comparison with cardiac magnetic resonance and single-photon emission computed tomography
    Yuki Tanabe
    Teruhito Kido
    Teruyoshi Uetani
    Akira Kurata
    Tamami Kono
    Akiyoshi Ogimoto
    Masao Miyagawa
    Tsutomu Soma
    Kenya Murase
    Hirotaka Iwaki
    Teruhito Mochizuki
    European Radiology, 2016, 26 : 3790 - 3801
  • [29] Pinhole single-photon emission computed tomography for myocardial perfusion imaging of mice
    Wu, MC
    Gao, DW
    Sievers, RE
    Lee, RJ
    Hasegawa, BH
    Dae, MW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (03) : 576 - 582
  • [30] Attenuation correction single-photon emission computed tomography myocardial perfusion imaging
    Bateman, TM
    Cullom, SJ
    SEMINARS IN NUCLEAR MEDICINE, 2005, 35 (01) : 37 - 51