Appearance of the Frequency-Doubling Stimulus at Threshold

被引:2
|
作者
Hogg, Ruth Esther [1 ]
Anderson, Andrew John [1 ]
机构
[1] Univ Melbourne, Dept Optometry & Vis Sci, Melbourne, Vic 3010, Australia
关键词
TECHNOLOGY PERIMETRY; PERIPHERAL-VISION; ILLUSION; GLAUCOMA; ADAPTATION; RESOLUTION; RESPONSES;
D O I
10.1167/iovs.08-2866
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. It has been argued that the threshold for detecting frequency-doubling (FD) technology perimeter stimuli differs from the threshold for perceiving spatial structure (pattern) in the same targets. Thresholds for perceiving spatial structure have typically been assessed using orientation-identification experiments. The authors investigated the influence of orientation, edge profile, and psychophysical method on the origin of the reported differences in detection and orientation-identification thresholds for FD gratings. METHODS. Detection and orientation-identification thresholds were determined in 12 observers with the use of FD stimuli (0.25 cyc/deg, 25 Hz) presented centrally and at 15 eccentricity. Edge profile (square- and Gaussian-windowed) and orientation (horizontal, vertical, and oblique) were independently modified. Detection thresholds were also measured for spatially uniform flickering targets (25 Hz). Orientation-identification thresholds using a two-alternative forced choice (2-AFC) and a two-interval forced choice (2-IFC) method were also compared in five experienced observers. RESULTS. Orientation-identification and detection thresholds did not significantly differ under any condition tested. Orientation-identification thresholds obtained with 2-AFC were not significantly different from those obtained with 2-IFC. Thresholds for spatially uniform flicker were significantly lower than for FD stimuli. CONCLUSIONS. The authors found that orientation-identification and detection thresholds for FD gratings did not differ and argue that recent findings to the contrary arise from the inappropriate use of spatially uniform flicker targets as alternatives in 2-IFC experiments. (Invest Ophthalmol Vis Sci. 2009; 50: 1477-1482) DOI:10.1167/iovs.08-2866
引用
收藏
页码:1477 / 1482
页数:6
相关论文
共 50 条
  • [11] Insights for mfVEPs from perimetry using large spatial frequency-doubling and near frequency-doubling stimuli in glaucoma
    Abdullah, Siti Nurliyana
    Sanderson, Gordon F.
    Husni, Mohd Aziz
    Maddess, Ted
    DOCUMENTA OPHTHALMOLOGICA, 2020, 141 (01) : 45 - 55
  • [12] Insights for mfVEPs from perimetry using large spatial frequency-doubling and near frequency-doubling stimuli in glaucoma
    Siti Nurliyana Abdullah
    Gordon F. Sanderson
    Mohd Aziz Husni
    Ted Maddess
    Documenta Ophthalmologica, 2020, 141 : 45 - 55
  • [13] ANNEALING EXPERIMENTS IN FREQUENCY-DOUBLING FIBERS
    GOUVEA, PMP
    MARGULIS, W
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1994, 11 (08) : 1515 - 1518
  • [14] Threshold and variability properties of matrix frequency-doubling technology and standard automated perimetry in glaucoma
    Artes, PH
    Hutchison, DM
    Nicolela, MT
    LeBlanc, RP
    Chauhan, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2451 - 2457
  • [15] Effect of dichoptic adaptation on frequency-doubling perimetry
    Anderson, AJ
    Johnson, CA
    OPTOMETRY AND VISION SCIENCE, 2002, 79 (02) : 88 - 92
  • [16] Frequency-doubling perimetry after photorefractive keratectomy
    Vetrugno, M
    Cardascia, N
    Maino, A
    Quaranta, GM
    Cardia, L
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12): : 2129 - 2134
  • [17] A new method of frequency-doubling with converging cavity
    Liu Dong
    Guo Jingwei
    Zhou Dongjian
    Jin Yuqi
    XX INTERNATIONAL SYMPOSIUM ON HIGH-POWER LASER SYSTEMS AND APPLICATIONS 2014, 2015, 9255
  • [18] HYDROTHERMAL KTP MEETS FREQUENCY-DOUBLING REQUIREMENTS
    DENTZ, DJ
    LASER FOCUS-ELECTRO-OPTICS, 1988, 24 (09): : 20 - 20
  • [19] Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma
    Boden, C
    Pascual, J
    Medeiros, FA
    Aihara, M
    Weinreb, RN
    Sample, PA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2433 - 2439
  • [20] Frequency-doubling technology perimetry and optical defocus
    Anderson, AJ
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (09) : 4147 - 4152