The development of a dynamic, six-axis spine simulator

被引:13
|
作者
Holsgrove, Timothy Patrick [1 ]
Gheduzzi, Sabina [1 ]
Gill, Harinderjit Singh [1 ]
Miles, Anthony W. [1 ]
机构
[1] Univ Bath, Dept Mech Engn, Ctr Orthopaed Biomech, Bath BA2 7AY, Avon, England
来源
SPINE JOURNAL | 2014年 / 14卷 / 07期
关键词
Spine biomechanics; Dynamic; Stiffness; Matrix; In vitro; Porcine; MOTION SEGMENT STIFFNESS; IN-VITRO; INTERVERTEBRAL DISC; LUMBAR; HYDRATION; BEHAVIOR; PORCINE; MODEL;
D O I
10.1016/j.spinee.2013.11.045
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Although a great deal of research has been completed to characterize the stiffness of spinal specimens, there remains a limited understanding of the spine in 6 df and there is a lack of data from dynamic testing in six axes. PURPOSE: This study details the development and validation of a dynamic six-axis spine simulator. STUDY DESIGN: Biomechanical study. METHODS: A synthetic spinal specimen was used for the purpose of tuning the simulator, completing positional accuracy tests, and measuring frequency response under physiological conditions. The spine simulator was used to complete stiffness matrix tests of an L3-L4 lumbar porcine functional spinal unit. Five testing frequencies were used, ranging from quasistatic (0.00575 Hz) to dynamic (0.5 Hz). Tests were performed without an axial preload and with an axial preload of 500 N. RESULTS: The validation tests demonstrated that the simulator is capable of producing accurate positioning under loading at frequencies up to 0.5 Hz using both sine and triangle waveforms. The porcine stiffness matrix tests demonstrated that the stiffness matrix is not symmetrical about the principal stiffness diagonal. It was also shown that while an increase in test frequency generally increased the principal stiffness terms, axial preload had a much greater effect. CONCLUSIONS: The spine simulator is capable of characterizing the dynamic biomechanics of the spine in six axes and provides a means to better understand the complex behavior of the spine under physiological conditions. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1308 / 1317
页数:10
相关论文
共 50 条
  • [41] Planar Six-Axis Force and Torque Sensors
    Wang, Yu-Jen
    Wu, Li-Chi
    Ke, Jian-Dong
    Lu, Tien-Fu
    IEEE SENSORS JOURNAL, 2021, 21 (23) : 26631 - 26641
  • [42] Vibratory ring six-axis motion sensor
    Abdul-wahed, Ahmed M.
    Mahmoud, Mohamed A. E.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2015, 21 (10): : 2133 - 2144
  • [43] Six-axis magnetic levitation and motion control
    Zhang, Zhipeng
    Menq, Chia-Hsiang
    IEEE TRANSACTIONS ON ROBOTICS, 2007, 23 (02) : 196 - 205
  • [44] Development and calibration of large deformation-compliant six-axis force sensor
    Huang, Xiaoming
    Yin, Zhongjun
    Li, Mingge
    Liu, Quan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (08)
  • [45] Development of a six-axis force/moment sensor for wind tunnel model test
    Wang, Wenjun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (11)
  • [46] Development and Application of a Novel High Precision Six-Axis Force/Torque Sensor
    Ren, Weizheng
    Yu, Kaile
    Zhang, Yiran
    Ge, Yutong
    Li, Yuxiao
    IEEE ACCESS, 2024, 12 : 104585 - 104598
  • [47] High dynamic range sensing by a multistage six-axis force sensor with stopper mechanism
    Okumura, Daisuke
    Sakaino, Sho
    Tsuji, Toshiaki
    2018 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2018, : 4065 - 4070
  • [48] Energy consumption and dynamic behavior analysis of a six-axis industrial robot in an assembly system
    Paryanto
    Brossog, Matthias
    Kohl, Johannes
    Merhof, Jochen
    Spreng, Simon
    Franke, Joerg
    5TH CATS 2014 - CIRP CONFERENCE ON ASSEMBLY TECHNOLOGIES AND SYSTEMS, 2014, 23 : 131 - 136
  • [49] Numerical analysis and experimental study on dynamic characteristic of six-axis force/torque table
    Lu, YM
    Liu, ZS
    Chen, XD
    Ge, YJ
    Wang, Y
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, 2002, : 382 - 386
  • [50] Dynamic coupling analysis of E-type membrane for six-axis force sensor
    1600, International Frequency Sensor Association (158):