Dosimetric and Radiobiological Consequences of Computed Tomography-Guided Adaptive Strategies for Intensity Modulated Radiation Therapy of the Prostate

被引:11
|
作者
Battista, Jerry J. [1 ,2 ,3 ]
Johnson, Carol [3 ]
Turnbull, David [3 ]
Kempe, Jeff [3 ]
Bzdusek, Karl [4 ]
Van Dyk, Jacob [1 ,2 ,3 ]
Bauman, Glenn [1 ,2 ,3 ]
机构
[1] Univ Western Ontario, Dept Med Biophys, London, ON N6A 5C1, Canada
[2] Univ Western Ontario, Dept Oncol, London, ON N6A 5C1, Canada
[3] London Hlth Sci Ctr, London Reg Canc Program, London, ON, Canada
[4] Philips Healthcare Radiat Oncol Syst, Fitchburg, WI USA
关键词
ONLINE RE-OPTIMIZATION; HELICAL TOMOTHERAPY; IMAGE-GUIDANCE; CANCER; RADIOTHERAPY; FAILURE; IMPACT; VOLUME; RISK; CT;
D O I
10.1016/j.ijrobp.2013.07.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To examine a range of scenarios for image-guided adaptive radiation therapy of prostate cancer, including different schedules for megavoltage CT imaging, patient repositioning, and dose replanning. Methods and Materials: We simulated multifraction dose distributions with deformable registration using 35 sets of megavoltage CT scans of 13 patients. We computed cumulative dose-volume histograms, from which tumor control probabilities and normal tissue complication probabilities (NTCPs) for rectum were calculated. Five-field intensity modulated radiation therapy (IMRT) with 18-MV x-rays was planned to achieve an isocentric dose of 76 Gy to the clinical target volume (CTV). The differences between D-95, tumor control probability, V-70Gy, and NTCP for rectum, for accumulated versus planned dose distributions, were compared for different target volume sizes, margins, and adaptive strategies. Results: The CTV D-95 for IMRT treatment plans, averaged over 13 patients, was 75.2 Gy. Using the largest CTV margins (10/7 mm), the D-95 values accumulated over 35 fractions were within 2% of the planned value, regardless of the adaptive strategy used. For tighter margins (5 mm), the average D-95 values dropped to approximately 73.0 Gy even with frequent repositioning, and daily replanning was necessary to correct this deficit. When personalized margins were applied to an adaptive CTV derived from the first 6 treatment fractions using the STAPLE (Simultaneous Truth and Performance Level Estimation) algorithm, target coverage could be maintained using a single replan 1 week into therapy. For all approaches, normal tissue parameters (rectum V-70Gy and NTCP) remained within acceptable limits. Conclusions: The frequency of adaptive interventions depends on the size of the CTV combined with target margins used during IMRT optimization. The application of adaptive target margins (<5 mm) to an adaptive CTV determined 1 week into therapy minimizes the need for subsequent dose replanning. (C) 2013 Elsevier Inc.
引用
收藏
页码:874 / 880
页数:7
相关论文
共 50 条
  • [21] Radiobiological considerations in the design of fractionation strategies for intensity-modulated radiation therapy of head and neck cancers
    Mohan, R
    Wu, QW
    Manning, M
    Schmidt-Ullrich, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (03): : 619 - 630
  • [22] Dosimetric effects of endorectal balloons on intensity-modulated radiation therapy plans for prostate cancer
    Jae-Sung Kim
    Jin-Beom Chung
    In-Ah Kim
    Keun-Yong Eom
    Journal of the Korean Physical Society, 2013, 63 : 1637 - 1643
  • [23] Dosimetric effects of endorectal balloons on intensity-modulated radiation therapy plans for prostate cancer
    Kim, Jae-Sung
    Chung, Jin-Beom
    Kim, In-Ah
    Eom, Keun-Yong
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (08) : 1637 - 1643
  • [24] Clinical and Dosimetric Comparison Between Non-image Guided Radiation Therapy and Fiducial-Based Image Guided Radiation Therapy With or Without Reduced Margin in Intensity Modulated Radiation Therapy for Prostate Cancer
    Serizawa, Itsuko
    Kozuka, Takuyo
    Soyano, Takashi
    Sasamura, Kazuma
    Kamima, Tatsuya
    Kunogi, Hiroaki
    Kurihara, Nozomi
    Numao, Noboru
    Yamamoto, Shinya
    Yonese, Junji
    Yoshioka, Yasuo
    ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (10)
  • [25] Radiation exposure during computed tomography-guided cryoablation of renal masses
    Burns, A. S.
    Bassignani, M. J.
    Schenkman, N. S.
    Theodorescu, D.
    Goode, A.
    Krupski, T. L.
    JOURNAL OF CLINICAL ONCOLOGY, 2010, 28 (15)
  • [26] INTENSITY MODULATED RADIATION THERAPY FOR PROSTATE CANCER
    Obata, S.
    Takatsuki, H.
    Ohta, Y.
    Kan, T.
    Kanegae, S.
    Inoue, Y.
    Matsuo, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S383 - S384
  • [27] Comparison of bone alignment and fiducial marker alignment for online cone-beam computed tomography-guided radiation therapy for prostate cancer
    Hussein M.Metwally
    Oncology and Translational Medicine, 2019, 5 (03) : 131 - 136
  • [28] Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation
    Ju, SG
    Ahn, YC
    Huh, SJ
    Yeo, IJ
    MEDICAL PHYSICS, 2002, 29 (03) : 351 - 355
  • [29] Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning
    Meyer, Sebastian
    Kamp, Florian
    Tessonnier, Thomas
    Mairani, Andrea
    Belka, Claus
    Carlson, David J.
    Gianoli, Chiara
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [30] In vivo dosimetric verification of intensity-modulated radiation therapy
    Chytyk-Praznik, K.
    Van Uytven, E.
    Van Beek, T.
    McCurdy, B. M. C.
    MEDICAL PHYSICS, 2012, 39 (07) : 4629 - 4629