New optimized model for water temperature calculation of river-water source heat pump and its application in simulation of energy consumption

被引:22
|
作者
Si, Pengfei [1 ,2 ]
Li, Angui [1 ]
Rong, Xiangyang [2 ]
Feng, Ya [2 ]
Yang, Zhengwu [2 ]
Gao, Qinglong [2 ]
机构
[1] Xian Univ Architecture & Technol, Xian 710055, Peoples R China
[2] China Southwest Architecture Design Inst, Chengdu 610042, Peoples R China
关键词
Water source heat pump; Air conditioning system; Host energy consumption; Water temperature model; Coefficient of performance (COP); SEAWATER; SYSTEM;
D O I
10.1016/j.renene.2015.06.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The energy consumption calculation plays an important role in the analysis of project economic and social benefits. In order to calculate energy consumption accurately, this research presents a water temperature of condenser inlet calculation model of river-water source heat pump unit. The feasibility and calculation error of the model had been analyzed. Additionally, the new water temperature calculation model had been validated via an engineering case. The results showed that the hourly water temperature in 24 h could be replaced by daily average water temperature due to little change of the daily water temperature change. In this case, the calculation error could be less than 5%. It is found that despite water temperature has many influenced factors, there is a remarkable relationship between the daily average water temperature and daily average outdoor dry bulb temperature by data analysis (R-2 approximate to 0.9). The influence of river sampling location on water temperature calculation of condenser inlet could be ignored due to slight temperature changes (within 0.15 degrees C). The method proposed in this paper met the engineering accuracy and provided a very effective method for the engineering calculation of energy consumption of water chilling unit. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 50 条
  • [31] Water Source Heat Pump Application for Thermal Power Plant
    Wei, Ji Peng
    Liang, Chen Xiao
    PROCEEDINGS OF THE 2013 8TH INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE & EDUCATION (ICCSE 2013), 2013, : 1249 - 1253
  • [32] Water temperature model of surface water heat pump and analysis of water capacity for cooling
    Dep. of Urban Construction, Nanjing University of Technology, Nanjing 210009, China
    不详
    Taiyangneng Xuebao, 2009, 10 (1198-1202):
  • [33] HEAT TRANSFER CHARACTERISTICS OF WATER ENERGY STORAGE TERMINAL DEVICE FOR NEW AIR SOURCE HEAT PUMP
    Shao X.
    Zhang H.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (12): : 420 - 424
  • [34] Theory of energy level and its application in water-loop heat pump system
    Dong, Yu Qi
    APPLIED THERMAL ENGINEERING, 2017, 119 : 269 - 274
  • [35] Energy Saving Analysis of Circulating Water Waste Heat Recovery from Water Source Heat Pump
    Ma, Chuang
    Ren, Jianxing
    Li, Fangqin
    Hou, Xin
    Feng, Haijun
    Zhang, Xiaotong
    2019 5TH INTERNATIONAL CONFERENCE ON ENERGY MATERIALS AND ENVIRONMENT ENGINEERING, 2019, 295
  • [36] Optimizing Energy Consumption Strategy of Water-loop Heat Pump
    Tu, Zhiyuan
    Peng, Fusheng
    Wang, Jie
    Huang, Chunjie
    2020 4TH INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2020), 2020, 510
  • [37] Static analysis on energy consumption of water loop heat pump system
    Ma, Zuiliang
    Cao, Yuan
    Harbin Jianzhu Daxue Xuebao/Journal of Harbin University of Civil Engineering and Architecture, 30 (06): : 68 - 74
  • [38] Simulation of Lake Water Source Heat Pump System Based on TRNSYS
    Qiao, Chunzhen
    Yang, Shaopeng
    Zhao, Yuqing
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENT ENGINEERING (ICSEEE 2016), 2016, 63 : 477 - 481
  • [39] Application of Solar Energy Water Heating System Combined with Air Source Heat Pump to the Constant Temperature Natatorium of Panzhihua University
    Wang, Jie
    Liang, Yuehua
    Yang, Mei
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2020, 126 : 275 - 276
  • [40] The simulation analysis of the affection of the water source heat pump of sea water intrusion in coastal region
    Chang'an University, College of Environmental Science and Engineering, Xi'an 710054, China
    不详
    Int. Conf. Electr. Control Eng., ICECE - Proc., 2011, (3748-3751):