A New Control Method to Generate RF signal for a Novel NMR Magnetometer

被引:0
|
作者
Wu, Chunli [1 ]
Lv, Fengchao [1 ]
Chen, Ying [1 ]
机构
[1] Northeastern Univ, Coll Informat Sci & Engn, Shenyang 110819, Peoples R China
来源
PROCEEDINGS OF THE 2012 24TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC) | 2012年
关键词
NMR Magnetometer; Direct Digital Synthesizer (DDS); Phase Locked Loop (PLL); Marginal Oscillator;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The main purpose of nuclear magnetic resonance (NMR) magnetometer is to calibrate the magnetic field. The core of the traditional NMR magnetometer is marginal oscillator, but the precision of marginal oscillator is not high enough. The paper chiefly presents a new control method to generate RF signal for a novel NMR magnetometer. The basic structure and operation principle of the novel NMR magnetometer is simply described here. In order to improve the precision of NMR magnetometer, the RF signal is generated by the Direct Digital Synthesizer (DDS) technology and the Phase Locked Loop (PLL) technology instead of the marginal oscillator. The circuit system of generating RF is designed and developed. The working performance is tested. Its precision is approximately 0.1ppm. The experimental result shows that this control method is feasible and the NMR signal can be detected clearly.
引用
收藏
页码:2773 / 2776
页数:4
相关论文
共 50 条
  • [21] A novel method to generate the geometry of a surface actuator
    Khalghollah, Mahmood
    Nayyeri, Pooyan
    Najafi, Farshid
    International Journal on Interactive Design and Manufacturing, 2020, 14 (01): : 211 - 223
  • [22] A novel method to generate the geometry of a surface actuator
    Khalghollah, Mahmood
    Nayyeri, Pooyan
    Najafi, Farshid
    INTERNATIONAL JOURNAL OF INTERACTIVE DESIGN AND MANUFACTURING - IJIDEM, 2020, 14 (01): : 211 - 223
  • [23] A novel method to generate the geometry of a surface actuator
    Mahmood Khalghollah
    Pooyan Nayyeri
    Farshid Najafi
    International Journal on Interactive Design and Manufacturing (IJIDeM), 2020, 14 : 211 - 223
  • [24] Investigation of NMR signal-to-noise ratio for RF scroll microcoils
    Gimi, B
    Grant, S
    Friedman, G
    Magin, R
    1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, : 88 - 91
  • [25] Research on the DDS' CPLD control to generate special band signal
    Yan, Shi Yu
    Li, Ji Zhou
    BMEI 2008: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOL 2, 2008, : 681 - +
  • [26] AMPLITUDE AND PHASE-CONTROL OF AN RF SIGNAL USING LIQUID-CRYSTALS BY OPTOELECTRONIC METHOD
    KOBAYASHI, O
    OGAWA, H
    IEICE TRANSACTIONS ON ELECTRONICS, 1995, E78C (08) : 1082 - 1089
  • [27] Using optimal control methods with constraints to generate singlet states in NMR
    Rodin, Bogdan A.
    Kiryutin, Alexey S.
    Yurkovskaya, Alexandra V.
    Ivanov, Konstantin L.
    Yamamoto, Satoru
    Sato, Kazunobu
    Takui, Takeji
    JOURNAL OF MAGNETIC RESONANCE, 2018, 291 : 14 - 22
  • [28] Novel Signal-to-Signal translation method based on StarGAN to generate artificial EEG for SSVEP-based brain-computer interfaces
    Kwon, Jinuk
    Im, Chang-Hwan
    EXPERT SYSTEMS WITH APPLICATIONS, 2022, 203
  • [29] A Novel Calibration Method for Magnetometer Array in Nonuniform Background Field
    Mu, Yaxin
    Wang, Chen
    Zhang, Xiaojuan
    Xie, Wupeng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (10) : 3677 - 3685
  • [30] NOVEL METHOD IN RF BIAS SPUTTERING
    NOMURA, I
    MIYAZAKI, T
    NISHIMURA, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 39 (1-4): : 99 - 103