A differential dielectric affinity glucose sensor

被引:20
|
作者
Huang, Xian [1 ]
Leduc, Charles [2 ]
Ravussin, Yann [2 ]
Li, Siqi [3 ]
Davis, Erin [3 ]
Song, Bing [1 ]
Li, Dachao [4 ]
Xu, Kexin [4 ]
Accili, Domenico [5 ]
Wang, Qian [3 ]
Leibel, Rudolph [2 ]
Lin, Qiao [1 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[2] Columbia Univ, Dept Pediat, Med Ctr, New York, NY 10032 USA
[3] Univ S Carolina, Dept Chem & Biochem, Columbia, SC 29208 USA
[4] Tianjin Univ, Coll Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
[5] Columbia Univ, Med Ctr, Dept Med, New York, NY 10032 USA
基金
美国国家卫生研究院;
关键词
IMPEDANCE SPECTROSCOPY; BIOCOMPATIBILITY; POLYMER; VISCOSITY;
D O I
10.1039/c3lc51026c
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A continuous glucose monitor with a differential dielectric sensor implanted within the subcutaneous tissue that determines the glucose concentration in the interstitial fluid is presented. The device, created using microelectromechanical systems (MEMS) technology, consists of sensing and reference modules that are identical in design and placed in close proximity. Each module contains a microchamber housing a pair of capacitive electrodes residing on the device substrate and embedded in a suspended, perforated polymer diaphragm. The microchambers, enclosed in semi-permeable membranes, are filled with either a polymer solution that has specific affinity to glucose or a glucose-insensitive reference solution. To accurately determine the glucose concentration, changes in the permittivity of the sensing and the reference solutions induced by changes in glucose concentration are measured differentially. In vitro characterization demonstrated the sensor was capable of measuring glucose concentrations from 0 to 500 mg dL(-1) with resolution and accuracy of similar to 1.7 mu g dL(-1) and similar to 1.74 mg dL(-1), respectively. In addition, device drift was reduced to 1.4% (uncontrolled environment) and 11% (5 degrees C of temperature variation) of that from non-differential measurements, indicating significant stability improvements. Preliminary animal testing demonstrated that the differential sensor accurately tracks glucose concentration in blood. This sensor can potentially be used clinically as a subcutaneously implanted continuous monitoring device in diabetic patients.
引用
收藏
页码:294 / 301
页数:8
相关论文
共 50 条
  • [41] Lossy Mode Resonance-Based Glucose Sensor with High-κ Dielectric Film
    Lin, Yu-Cheng
    Chen, Liang-Yu
    Chiu, Fu-Chien
    CRYSTALS, 2019, 9 (09):
  • [42] A new rectangular dielectric resonator sensor for glucose measurement: Design, modeling, and experimental validation
    Marzouk, Hala M.
    Abd El-Hameed, Anwer S.
    Allam, Ahmed
    Pokharel, Ramesh K.
    Abdel-Rahman, Adel B.
    INTERNATIONAL JOURNAL OF CIRCUIT THEORY AND APPLICATIONS, 2024, 52 (06) : 3040 - 3051
  • [43] Effects of Thumb Size, Pressure, Position, Nail, and Skin on Dielectric Resonator Glucose Sensor
    Hasan, Md Nazmul
    Chu, Son
    Yousaf, Jawad
    2020 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION AND NORTH AMERICAN RADIO SCIENCE MEETING, 2020, : 1511 - 1512
  • [44] Comprehensive System for Noninvasive Glucose Monitoring Utilizing a Rectangular Dielectric Resonator Microwave Sensor
    Marzouk, Hala M.
    Abd El-Hameed, Anwer S.
    Allam, Ahmed
    Pokharel, Ramesh K.
    Abdel-Rahman, Adel B.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [45] Glucokinase, the pancreatic glucose sensor, is not the gut glucose sensor
    R. Murphy
    A. Tura
    P. M. Clark
    J. J. Holst
    A. Mari
    A. T. Hattersley
    Diabetologia, 2009, 52
  • [46] Tonometric biosensor with a differential pressure sensor for chemo-mechanical measurement of glucose
    Mitsubayashi, Kohji
    Ohgoshi, Takahiro
    Okamoto, Toshiaki
    Wakabayashi, Yoshihiko
    Kozuka, Masaharu
    Miyajima, Kumiko
    Saito, Hirokazu
    Kudo, Hiroyuki
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (05): : 1518 - 1521
  • [47] Glucokinase, the pancreatic glucose sensor, is not the gut glucose sensor
    Murphy, R.
    Tura, A.
    Clark, P. M.
    Holst, J. J.
    Mari, A.
    Hattersley, A. T.
    DIABETOLOGIA, 2009, 52 (01) : 154 - 159
  • [48] Fungal FAD-dependent glucose dehydrogenases concerning high activity, affinity, and thermostability for maltose-insensitive blood glucose sensor
    Iwasa, Hisanori
    Ozawa, Kazumichi
    Sasaki, Noriko
    Kinoshita, Nao
    Yokoyama, Kenji
    Hiratsuka, Atsunori
    BIOCHEMICAL ENGINEERING JOURNAL, 2018, 140 : 115 - 122
  • [49] The Glucose Sensor-Like Protein Hxs1 Is a High-Affinity Glucose Transporter and Required for Virulence in Cryptococcus neoformans
    Liu, Tong-Bao
    Wang, Yina
    Baker, Gregory M.
    Fahmy, Hany
    Jiang, Linghuo
    Xue, Chaoyang
    PLOS ONE, 2013, 8 (05):
  • [50] An Improved Differential CSRR-Based Sensor for Characterizing the Magneto-Dielectric Materials
    Gan, Hong-Yi
    Li, Li-Qun
    Zhao, Wen-Sheng
    Wang, Da-Wei
    Wang, Gaofeng
    2020 IEEE MTT-S INTERNATIONAL CONFERENCE ON NUMERICAL ELECTROMAGNETIC AND MULTIPHYSICS MODELING AND OPTIMIZATION (NEMO 2020), 2020,