Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography

被引:12
|
作者
Brugaletta, Salvatore [1 ,2 ]
Garcia-Garcia, Hector M. [1 ,3 ]
Gomez-Lara, Josep [1 ]
Radu, Maria D. [1 ]
Pawar, Ravindra [1 ,3 ]
Khachabi, Jamal [3 ]
Bruining, Nico
Sabate, Manel [2 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Hosp Clin Barcelona, Dept Cardiol, Thorax Inst, Barcelona, Spain
[3] Cardialysis BV, Rotterdam, Netherlands
来源
关键词
OCT; Coverage; Strut; Stent; DRUG-ELUTING STENTS; NEOINTIMAL COVERAGE; BARE-METAL; IMPLANTATION;
D O I
10.1007/s10554-012-0030-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Assessment of stent strut coverage by optical coherence tomography (OCT) is not standardized. The methodology most commonly used is based on a visual binary qualitative assessment (strut covered or not). However, the influence of magnification (zoom setting) to the inter- and intra-observer agreements has not yet been evaluated. Aim of our study was therefore to evaluate the agreements of this approach, taking into account various zoom settings. 126 struts from 10 selected frames were independently evaluated by four observers using a stepwise approach increasing the zoom setting as following: (1) full view of the lumen (FV), (2) half view of the lumen (HV) and (3) a quarter view of the lumen (QV). Intra- and inter-observer agreements (kappa) were assessed. The rate of uncoverage was determined for each strut as the number of times it was defined as uncovered divided by the total number of observations (maximum 12 = 3 zoom settings x 4 analysts) and expressed as percentage. The inter-observer kappa values (mean [range]) were 0.32 [0.07-0.63], 0.40 [0.18-0.69] and 0.33 [0.09-0.6], within FV, HV and QV respectively. The intra-observer kappa values were 0.60 [0.50-0.70], 0.75 [0.75-0.76] and 0.60 [0.50-0.70], within FV, HV and QV respectively. By increasing zoom setting the kappa value of intra-observer agreement was 0.74 [0.58-0.83] (from FV to HV), 0.70 [0.56-0.83] (from HV to QV) and 0.70 [0.37-0.86] (from FV to QV). Overall, the rate of uncoverage was 15.5% [8.3-100%]. The OCT qualitative evaluation of strut coverage has wide inter and intra-observer agreements and is dependent of the zoom setting used during the analysis. A more reproducible approach would be needed to eventually increase the probability to link uncovered struts with clinical events.
引用
收藏
页码:5 / 11
页数:7
相关论文
共 50 条
  • [21] Correlation of angiographic late loss with neointimal coverage of drug-eluting stent struts on follow-up optical coherence tomography
    Byeong-Keuk Kim
    Jung-Sun Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 1289 - 1297
  • [22] Neointimal Coverage on the Stent Struts across Ostia of Aretrial Branches Differs in the Vessel Size of the Side Branch: An Optical Coherence Tomography Study
    Mizukoshi, Masato
    Imanishi, Toshio
    Tanaka, Atsushi
    Kubo, Takashi
    Hirata, Kumiko
    Takarada, Shigeho
    Kitabata, Hironori
    Ino, Yasushi
    Tanimoto, Takashi
    Komukai, Kenichi
    Kuroi, Akio
    Satogami, Keisuke
    Ikejima, Hideyuki
    Kashiwagi, Manabu
    Tsujioka, Hiroto
    Matsumoto, Hiroki
    Ozaki, Yuichi
    Wada, Nozomi
    Nishiguchi, Tsuyoshi
    Masuno, Tomizou
    Maniwa, Naoki
    Teraguchi, Ikuko
    Liu, Yong
    Akasaka, Takashi
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 57D - 57D
  • [23] Correlation of angiographic late loss with neointimal coverage of drug-eluting stent struts on follow-up optical coherence tomography
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1289 - 1297
  • [24] Accuracy and Reproducibility of Stent-Strut Thickness Determined by Optical Coherence Tomography
    Terashima, Mitsuyasu
    Rathore, Sudhir
    Suzuki, Yasuyoshi
    Nakayama, Yoshiaki
    Kaneda, Hideaki
    Nasu, Kenya
    Habara, Maoto
    Katoh, Osamu
    Suzuki, Takahiko
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2009, 21 (11): : 602 - 605
  • [25] Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation
    Byeong-Keuk Kim
    Jung-Sun Kim
    Changmyung Oh
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 705 - 714
  • [26] Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Oh, Changmyung
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04): : 705 - 714
  • [27] Automatic stent struts detection in optical coherence tomography based on a multiple attention convolutional model
    Han, Tingting
    Xia, Wei
    Tao, Kuiyuan
    Wang, Wei
    Gao, Jing
    Ding, Xiaoming
    Zhong, Hongmei
    Liu, Ruqian
    Dou, Shuwei
    Liu, Zixu
    Kuang, Hao
    Hua, Jiarui
    Xu, Keyong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (01):
  • [28] Black Spot Surrounding Stent Struts Observed by Optical Coherence Tomography; What Do These Represent?
    Teramoto, Tomohiko
    Ikeno, Fumiaki
    Lyons, Jennifer
    Ootake, Hiromasa
    Yeung, Alan C.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A90 - A90
  • [29] Automated Three-Dimensional Detection of Intracoronary Stent Struts in Optical Coherence Tomography Images
    Bruining, Nico
    Sihan, Kenji
    Ligthart, Jurgen
    Cummins, Paul
    de Winter, Sebastiaan
    Regar, Evelyn
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B181 - B181
  • [30] High-speed automatic segmentation of intravascular stent struts in optical coherence tomography images
    Han, M.
    Kim, D.
    Oh, W. Y.
    Ryu, S.
    [J]. PHOTONIC THERAPEUTICS AND DIAGNOSTICS IX, 2013, 8565