Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography

被引:12
|
作者
Brugaletta, Salvatore [1 ,2 ]
Garcia-Garcia, Hector M. [1 ,3 ]
Gomez-Lara, Josep [1 ]
Radu, Maria D. [1 ]
Pawar, Ravindra [1 ,3 ]
Khachabi, Jamal [3 ]
Bruining, Nico
Sabate, Manel [2 ]
Serruys, Patrick W. [1 ]
机构
[1] Erasmus MC, Thoraxctr, NL-3015 CE Rotterdam, Netherlands
[2] Hosp Clin Barcelona, Dept Cardiol, Thorax Inst, Barcelona, Spain
[3] Cardialysis BV, Rotterdam, Netherlands
来源
关键词
OCT; Coverage; Strut; Stent; DRUG-ELUTING STENTS; NEOINTIMAL COVERAGE; BARE-METAL; IMPLANTATION;
D O I
10.1007/s10554-012-0030-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Assessment of stent strut coverage by optical coherence tomography (OCT) is not standardized. The methodology most commonly used is based on a visual binary qualitative assessment (strut covered or not). However, the influence of magnification (zoom setting) to the inter- and intra-observer agreements has not yet been evaluated. Aim of our study was therefore to evaluate the agreements of this approach, taking into account various zoom settings. 126 struts from 10 selected frames were independently evaluated by four observers using a stepwise approach increasing the zoom setting as following: (1) full view of the lumen (FV), (2) half view of the lumen (HV) and (3) a quarter view of the lumen (QV). Intra- and inter-observer agreements (kappa) were assessed. The rate of uncoverage was determined for each strut as the number of times it was defined as uncovered divided by the total number of observations (maximum 12 = 3 zoom settings x 4 analysts) and expressed as percentage. The inter-observer kappa values (mean [range]) were 0.32 [0.07-0.63], 0.40 [0.18-0.69] and 0.33 [0.09-0.6], within FV, HV and QV respectively. The intra-observer kappa values were 0.60 [0.50-0.70], 0.75 [0.75-0.76] and 0.60 [0.50-0.70], within FV, HV and QV respectively. By increasing zoom setting the kappa value of intra-observer agreement was 0.74 [0.58-0.83] (from FV to HV), 0.70 [0.56-0.83] (from HV to QV) and 0.70 [0.37-0.86] (from FV to QV). Overall, the rate of uncoverage was 15.5% [8.3-100%]. The OCT qualitative evaluation of strut coverage has wide inter and intra-observer agreements and is dependent of the zoom setting used during the analysis. A more reproducible approach would be needed to eventually increase the probability to link uncovered struts with clinical events.
引用
收藏
页码:5 / 11
页数:7
相关论文
共 50 条
  • [1] Reproducibility of qualitative assessment of stent struts coverage by optical coherence tomography
    Salvatore Brugaletta
    Hector M. Garcia-Garcia
    Josep Gomez-Lara
    Maria D. Radu
    Ravindra Pawar
    Jamal Khachabi
    Nico Bruining
    Manel Sabaté
    Patrick W. Serruys
    [J]. The International Journal of Cardiovascular Imaging, 2013, 29 : 5 - 11
  • [2] Automatic assessment of stent neointimal coverage by intravascular optical coherence tomography
    Ughi, Giovanni J.
    Van Dyck, Christophe J.
    Adriaenssens, Tom
    Hoymans, Vicky Y.
    Sinnaeve, Peter
    Timmermans, Jean-Pierre
    Desmet, Walter
    Vrints, Christiaan J.
    D'hooge, Jan
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (02) : 195 - 200
  • [3] Automated detection of vessel lumen and stent struts in intravascular optical coherence tomography to evaluate stent apposition and neointimal coverage
    Nam, Hyeong Soo
    Kim, Chang-Soo
    Lee, Jae Joong
    Song, Joon Woo
    Kim, Jin Won
    Yoo, Hongki
    [J]. MEDICAL PHYSICS, 2016, 43 (04) : 1662 - 1675
  • [4] Reproducibility of quantitative optical coherence tomography for stent analysis
    Gonzalo, Nieves
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    Commissaris, Koen H.
    Bezerra, Hiram
    Gobbens, Pierre
    Costa, Marco
    Regar, Evelyn
    [J]. EUROINTERVENTION, 2009, 5 (02) : 224 - 232
  • [5] Reproducibility of quantitative optical coherence tomography for stent analysis
    Lopez, N. Gonzalo
    Garcia-Garcia, H. M.
    Serruys, P. W.
    Commissaris, K.
    Bezerra, H.
    Gobbens, P.
    Costa, M.
    Regar, E.
    [J]. EUROPEAN HEART JOURNAL, 2009, 30 : 675 - 675
  • [6] Reproducibility Of Quantitative Optical Coherence Tomography For Stent Analysis
    Gonzalo, Nieves
    Garcia-Garcia, Hector M.
    Serruys, Patrick W.
    Commissaris, Koen H.
    Bezerra, Hiram
    Gobbens, Pierre
    Costa, Marco
    Regar, Evelyn
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 55D - 56D
  • [7] Optical Coherence Tomography Assessment of Neointimal Coverage According to the Presence Or Absence Of Malapposed Struts After Drug-eluting Stent Implantation
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B184 - B184
  • [8] Intra- and interobserver reliability and intra-catheter reproducibility using frequency domain optical coherence tomography for the evaluation of morphometric stent parameters and qualitative assessment of stent strut coverage
    Antonsen, Lisbeth
    Thayssen, Per
    Junker, Anders
    Veien, Karsten Tange
    Hansen, Henrik Steen
    Hansen, Knud Norregaard
    Hougaard, Mikkel
    Jensen, Lisette Okkels
    [J]. CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2015, 16 (08) : 469 - 477
  • [9] Comparison of optical coherence tomography and intravascular ultrasound for the assessment of in-stent tissue coverage after stent implantation
    Capodanno, Davide
    Prati, Francesco
    Pawlowsky, Tomasz
    Cera, Maria
    La Manna, Alessio
    Albertucci, Mario
    Tamburino, Corrado
    [J]. EUROINTERVENTION, 2009, 5 (05) : 538 - 543
  • [10] Optical coherence tomography assessment of strut coverage of a fully biodegradable Everolimus-eluting stent
    Kukreja, N.
    Regar, E.
    De Winter, S.
    Bruining, N.
    Sianos, G.
    Serruys, P. W.
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 : 263 - 263