Study on cold head structure of a 300 Hz thermoacoustically driven pulse tube cryocooler

被引:7
|
作者
Yu, G. Y. [1 ]
Wang, X. T. [1 ]
Dai, W. [1 ]
Luo, E. C. [1 ]
机构
[1] Chinese Acad Sci, Key Lab Cryogen, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
基金
中国国家自然科学基金;
关键词
High frequency; Standing wave thermoacoustic heat engine; Pulse tube cryocooler; Cold head structure; REFRIGERATOR; ENGINE;
D O I
10.1016/j.cryogenics.2012.01.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
High reliability, compact size and potentially high thermal efficiency make the high frequency thermoacoustically-driven pulse tube cryocooler quite promising for space use. With continuous efforts, the lowest temperature and the thermal efficiency of the coupled system have been greatly improved. So far, a cold head temperature below 60 K has been achieved on such kind of cryocooler with the operation frequency of around 300 Hz. To further improve the thermal efficiency and expedite its practical application, this work focuses on studying the influence of cold head structure on the system performance. Substantial numerical simulations were firstly carried out, which revealed that the cold head structure would greatly influence the cooling power and the thermal efficiency. To validate the predictions, a lot of experiments have been done. The experiments and calculations are in reasonable agreement. With 500 W heating power input into the engine, a no-load temperature of 63 K and a cooling power of 1.16 W at 80 K have been obtained with parallel-plate cold head, indicating encouraging improvement of the thermal efficiency. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:212 / 215
页数:4
相关论文
共 50 条
  • [21] 92 K thermoacoustically driven pulse tube refrigerator
    TANG Ke
    Chinese Science Bulletin, 2004, (14) : 1541 - 1542
  • [22] STUDY ON A SINGLE-STAGE 120HZ PULSE TUBE CRYOCOOLER
    Wu, Y. Z.
    Gan, Z. H.
    Qiu, L. M.
    Chen, J.
    Li, Z. P.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 175 - 182
  • [23] Effect of inertance tube on thermoacoustically driven pulse tube refrigeration performance
    Cryogenics Laboratory, Zhejiang University, Hangzhou 310027, China
    Kung Cheng Je Wu Li Hsueh Pao, 2008, 10 (1633-1635): : 1633 - 1635
  • [24] Numerical investigation on a 300 Hz pulse tube cryocooler driven by a three-stage traveling-wave thermoacoustic heat engine
    Xu, Jingyuan
    Yu, Guoyao
    Zhang, Limin
    Dai, Wei
    Wu, Zhanghua
    Luo, Ercang
    CRYOGENICS, 2015, 71 : 68 - 75
  • [25] Cryogenic-temperature thermoacoustically driven pulse tube refrigerator
    Jin, T
    Chen, GB
    Shen, Y
    Huang, YH
    Wu, ZH
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 836 - 843
  • [26] An innovative configuration for thermoacoustically-driven pulse tube coolers
    Hu, JY
    Luo, EC
    Dai, W
    CRYOGENICS, 2005, 45 (07) : 523 - 527
  • [27] Influence of resonance tube length on performance of thermoacoustically driven pulse tube refrigerator
    Tang, K
    Chen, GB
    Jin, T
    Bao, R
    Kong, B
    Qiu, LM
    CRYOGENICS, 2005, 45 (03) : 185 - 191
  • [28] Study of a 72 Hz high-capacity pulse tube cryocooler for space applications
    Wang N.
    Zhao M.
    Chen H.
    Liang J.
    Zhao, Miguang (mgzhao@mail.ipc.ac.cn), 2018, Chinese Academy of Sciences (63): : 3968 - 3974
  • [29] Theoretical analysis of two coupling modes of a 300-Hz three-stage thermoacoustically driven cryocooler system at liquid nitrogen temperature range
    Xu, Jingyuan
    Yu, Guoyao
    Zhang, Limin
    Dai, Wei
    Luo, Ercang
    APPLIED ENERGY, 2017, 185 : 2134 - 2141
  • [30] 120 Hz pulse tube cryocooler for fast cooldown to 50 K
    Vanapalli, Srinivas
    Lewis, Michael
    Gan, Zhihua
    Radebaugh, Ray
    APPLIED PHYSICS LETTERS, 2007, 90 (07)