A Laboratory Scanner for Cone Beam Breast Computed Tomography

被引:0
|
作者
Russo, P. [1 ]
Mettivier, G. [1 ]
Lauria, A. [1 ]
Montesi, M. C. [1 ]
机构
[1] Univ Naples Federico II, Dipartimento Sci Fis, Via Cinthia, I-80126 Naples, Italy
关键词
Breast Computed Tomography; Cone Beam Computed Tomography; Mammography; Flat Panel detector; CT; FEASIBILITY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present the system and the first images of a laboratory scanner for X-ray cone-beam breast computed tomography (CBBCT). This modular and versatile apparatus allows for testing various setup parameters for CBBCT, including fan-beam, cone-beam or helical scans and intensity or kilovoltage modulated scans. It also allows to implement digital breast tomosynthesis. Preliminary CT scans of test objects will be shown. The scanner design includes also two compact gamma cameras on the rotating gantry in order to perform combined CT and SPECT imaging, in a future version of the device.
引用
收藏
页码:563 / 565
页数:3
相关论文
共 50 条
  • [41] Use of Cone Beam Computed Tomography in Endodontics
    Scarfe, William C.
    Levin, Martin D.
    Gane, David
    Farman, Allan G.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2009, 2009
  • [42] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    DENTISTRY JOURNAL, 2019, 7 (03)
  • [43] Dual-energy computed tomography using a gantry-based preclinical cone-beam microcomputed tomography scanner
    Tse, Justin J.
    Dunmore-Buyze, Joy
    Drangova, Maria
    Holdsworth, David W.
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (03)
  • [44] X-ray Cone-Beam Breast Computed Tomography: phantom studies
    Russo, P.
    Lauria, A.
    Mettivier, G.
    Montesi, M. C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4076 - 4083
  • [45] X-ray Cone-Beam Breast Computed Tomography: Phantom Studies
    Russo, Paolo
    Mettivier, Giovanni
    Lauria, Adele
    Montesi, Maria Cristina
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 160 - 172
  • [46] Dose Distribution in Cone-Beam Breast Computed Tomography: An Experimental Phantom Study
    Russo, Paolo
    Lauria, Adele
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Villani, Natalia
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 366 - 374
  • [47] A Prototype of Cone-Beam Breast Computed Tomography System and its Performance Evaluation
    Xiao, Dayu
    Xu, Lisheng
    Qi, Shouliang
    Yao, Yupeng
    Kang, Yan
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 66 - 69
  • [48] Cone-beam breast computed tomography with a displaced flat panel detector array
    Mettivier, Giovanni
    Russo, Paolo
    Lanconelli, Nico
    Lo Meo, Sergio
    MEDICAL PHYSICS, 2012, 39 (05) : 2805 - 2819
  • [49] A review of setup error in supine breast radiotherapy using cone -beam computed tomography
    Batumalai, Vikneswary
    Holloway, Lois
    Delaney, Geoff P.
    MEDICAL DOSIMETRY, 2016, 41 (03) : 225 - 229
  • [50] Dose Distribution in Cone-Beam Breast Computed Tomography: an experimental Phantom Study
    Russo, P.
    Lauria, A.
    Mettivier, G.
    Montesi, M. C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5382 - 5387