A Laboratory Scanner for Cone Beam Breast Computed Tomography

被引:0
|
作者
Russo, P. [1 ]
Mettivier, G. [1 ]
Lauria, A. [1 ]
Montesi, M. C. [1 ]
机构
[1] Univ Naples Federico II, Dipartimento Sci Fis, Via Cinthia, I-80126 Naples, Italy
关键词
Breast Computed Tomography; Cone Beam Computed Tomography; Mammography; Flat Panel detector; CT; FEASIBILITY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We present the system and the first images of a laboratory scanner for X-ray cone-beam breast computed tomography (CBBCT). This modular and versatile apparatus allows for testing various setup parameters for CBBCT, including fan-beam, cone-beam or helical scans and intensity or kilovoltage modulated scans. It also allows to implement digital breast tomosynthesis. Preliminary CT scans of test objects will be shown. The scanner design includes also two compact gamma cameras on the rotating gantry in order to perform combined CT and SPECT imaging, in a future version of the device.
引用
收藏
页码:563 / 565
页数:3
相关论文
共 50 条
  • [1] Measurement of the MTF of a Cone-Beam Breast Computed Tomography Laboratory Scanner
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Lauria, Adele
    Russo, Paolo
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3958 - 3964
  • [2] Measurement of the MTF of a Cone-Beam Breast Computed Tomography Laboratory Scanner
    Mettivier, Giovanni
    Russo, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 703 - 713
  • [3] Comparison of a Novel Weightbearing Cone Beam Computed Tomography Scanner Versus a Conventional Computed Tomography Scanner for Measuring Patellar Instability
    Marzo, John
    Kluczynski, Melissa
    Notino, Anthony
    Bisson, Leslie
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2016, 4 (12):
  • [4] A calibration method for misaligned scanner geometry in cone-beam computed tomography
    Sun, Yi
    Hou, Ying
    Zhao, Fengyong
    Hu, Jiasheng
    NDT & E INTERNATIONAL, 2006, 39 (06) : 499 - 513
  • [5] Movement of the patient and the cone beam computed tomography scanner: objectives and possible solutions
    Hanzelka, Tomas
    Dusek, Jaroslav
    Ocasek, Filip
    Kucera, Josef
    Sedy, Jiri
    Benes, Jiri
    Pavlikova, Gabriela
    Foltan, Rene
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (06): : 769 - 773
  • [6] Marker trajectory assessment in optical cone beam computed tomography scanner geometry
    Marks, Gareth
    Jaryd, Christie
    Jordan, Kevin
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167
  • [7] Cone beam optical computed tomography for gel dosimetry I: scanner characterization
    Olding, Tim
    Holmes, Oliver
    Schreiner, L. John
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10): : 2819 - 2840
  • [8] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    De Cock, Jens
    Zanca, Federica
    Canning, John
    Pauwels, Ruben
    Hermans, Robert
    EUROPEAN RADIOLOGY, 2015, 25 (07) : 1891 - 1900
  • [9] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    Jens De Cock
    Federica Zanca
    John Canning
    Ruben Pauwels
    Robert Hermans
    European Radiology, 2015, 25 : 1891 - 1900
  • [10] Cone-beam micro computed tomography dedicated to the breast
    Sarno, Antonio
    Mettivier, Giovanni
    Di Lillo, Francesca
    Cesarelli, Mario
    Bifulco, Paolo
    Russo, Paolo
    MEDICAL ENGINEERING & PHYSICS, 2016, 38 (12) : 1449 - 1457