Characteristics of detection thresholds and maximum comfortable loudness levels as a function of pulse rate in human cochlear implant users

被引:32
|
作者
Zhou, Ning [1 ]
Xu, Li [1 ,2 ]
Pfingst, Bryan E. [1 ]
机构
[1] Univ Michigan, Dept Otolaryngol, Kresge Hearing Res Inst, Ann Arbor, MI 48109 USA
[2] Ohio Univ, Sch Rehabil & Commun Sci, Athens, OH 45701 USA
关键词
PULSATILE ELECTRICAL-STIMULATION; MODULATION DETECTION; INTENSITY DISCRIMINATION; TEMPORAL INTEGRATION; SPEECH-PERCEPTION; ELECTRODE; POSITION; RECOGNITION; FREQUENCY; GROWTH;
D O I
10.1016/j.heares.2011.12.008
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
The ability of an implanted ear to integrate multiple pulses, as measured by the slopes of detection threshold level (T level) versus pulse rate functions, may reflect cochlear health in the cochlea, as suggested by previous animal studies (Kang et al., 2010; Pfingst et al., 2011). In the current study, we examined the slopes of T level versus pulse rate functions in human subjects with cochlear implants. Typically, T levels decrease as a function of pulse rate, consistent with a multipulse integration mechanism. The magnitudes of the slopes of the T level versus pulse rate functions obtained from the human subjects were comparable to those reported in the animal studies. The slopes varied across stimulation sites, but did not change systematically along the tonotopic axis. This suggests that the slopes are dependent on local conditions near the individual stimulation sites. The characteristics of these functions were also similar to those found in animals in that the slopes for higher pulse rates were steeper than those for the lower pulse rates, consistent with a combined effect of multipulse integration and cumulative partial depolarization mechanisms at rates above 1000 pps. The maximum comfortable loudness level (C level) versus pulse rate functions were also examined to determine the effect of level on the slopes. Slopes of C-level functions were shallower than those for the T-level functions and were not correlated with those of the T-level functions, so the mechanisms underlying these two functions are probably not identical. The slopes of the T- or C-level functions were not dependent on stimulus-current level. Based on these results, we suggest that slopes of T level versus pulse rate functions might be a useful measure for estimating nerve survival in the cochlea in regions close to the stimulation sites. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [31] Effects of stimulation rate on modulation detection and speech recognition by cochlear implant users
    Arora, Komal
    Vandali, Andrew
    Dowell, Richard
    Dawson, Pam
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2011, 50 (02) : 123 - 132
  • [32] Effects of stimulation rate, mode and level on modulation detection by cochlear implant users
    Galvin, JJ
    Fu, QJ
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2005, 6 (03): : 269 - 279
  • [33] Effects of Stimulation Rate, Mode and Level on Modulation Detection by Cochlear Implant Users
    John J. Galvin
    Qian-Jie Fu
    Journal of the Association for Research in Otolaryngology, 2005, 6 : 269 - 279
  • [34] Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users
    Cosentino, Stefano
    Carlyon, Robert P.
    Deeks, John M.
    Parkinson, Wendy
    Bierer, Julie A.
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2016, 17 (04): : 371 - 382
  • [35] Rate discrimination, gap detection and ranking of temporal pitch in cochlear implant users
    Stefano Cosentino
    Robert P. Carlyon
    John M. Deeks
    Wendy Parkinson
    Julie A. Bierer
    Journal of the Association for Research in Otolaryngology, 2016, 17 : 371 - 382
  • [36] A method to dynamically control unwanted loudness cues when measuring amplitude modulation detection in cochlear implant users
    Galvin, John J., III
    Fu, Qian-Jie
    Oba, Sandy
    Baskent, Deniz
    JOURNAL OF NEUROSCIENCE METHODS, 2014, 222 : 207 - 212
  • [37] Stream segregation on a single electrode as a function of pulse rate in cochlear implant listeners
    Duran, Sara I.
    Collins, Leslie M.
    Throckmorton, Chandra S.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2012, 132 (06): : 3849 - 3855
  • [38] Effects of pulse rate on threshold and dynamic range in Clarion cochlear-implant users (L)
    Kreft, HA
    Donaldson, GS
    Nelson, DA
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (05): : 1885 - 1888
  • [39] Effect of Pulse Rate and Polarity on the Sensitivity of Auditory Brainstem and Cochlear Implant Users to Electrical Stimulation
    Robert P. Carlyon
    John M. Deeks
    Colette M. McKay
    Journal of the Association for Research in Otolaryngology, 2015, 16 : 653 - 668
  • [40] Advantages of Pulse Rate Compared to Modulation Frequency for Temporal Pitch Perception in Cochlear Implant Users
    Goldsworthy, Raymond L.
    Bissmeyer, Susan R. S.
    Camarena, Andres
    JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY, 2022, 23 (01): : 137 - 150