Investigation of the Imbalance Current Compensation for Transformers Used in Electric Railways

被引:0
|
作者
Dai, Chenxi [1 ]
Sun, Yuanyuan [2 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou, Zhejiang, Peoples R China
[2] Shandong Univ, Sch Elect Engn, Jinan, Peoples R China
关键词
Compensation capacity; Electric railway; Imbalance current; Specially-connected transformers;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Different transformer connections have different influences on the imbalance current introduced by the electric traction load. From transformers' symmetrical components matrices, the conditions under which there will be lest current injected into the primary windings of the transformer are studied. Capacitors or inductors can be installed to compensate the traction load to reach these conditions. Based on the deduced balance criteria, the compensation capacities for several specially connected transformers are researched. Analysis found out that for Scott transformer, Le-Blanc transformer and Modified Wood-bridge transformer, it is useful to install combination of inductors and capacitors on the secondary winding of transformers in order to reduce imbalance current.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Limitations of the H-Bridge Multilevel STATCOMs in Compensation of Current Imbalance
    Basic, Duro
    Geske, Martin
    Schroeder, Stefan
    2015 17TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'15 ECCE-EUROPE), 2015,
  • [32] Z2 Electric Multiple Units Used on French National Railways.
    Coget, Gerard
    Revue Generale des Chemins de Fer, 1981, 100 : 661 - 678
  • [33] Residual Flux Mitigation of Protective Current Transformers Used in an Autoreclosing Scheme
    Hajipour, Ehsan
    Salehizadeh, Mohammad
    Vakilian, Mehdi
    Sanaye-Pasand, Majid
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (04) : 1636 - 1644
  • [34] AGING TESTS OF AMORPHOUS CURRENT TRANSFORMERS USED IN GROUND FAULT INTERRUPTERS
    NAFALSKI, A
    MATRAS, G
    WACWLODARCZYK, A
    STRYCZEWSKA, H
    IEEE TRANSACTIONS ON MAGNETICS, 1990, 26 (05) : 2005 - 2007
  • [35] Temperature error compensation technology of all-fiber optical current transformers
    Xiao, Hao
    Liu, Boyang
    Wan, Shiwei
    Zhao, Yucai
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2011, 35 (21): : 91 - 95
  • [36] Compensation of Current Transformers' Non-Linearities by Means of Frequency Coupling Matrices
    Collin, A. J.
    Delle Femine, A.
    Gallo, D.
    Langella, R.
    Luiso, M.
    2018 IEEE 9TH INTERNATIONAL WORKSHOP ON APPLIED MEASUREMENTS FOR POWER SYSTEMS (AMPS), 2018, : 53 - 58
  • [37] Analysis of Electric Railways Influence on Electrical Power System - current and voltage harmonics
    Palecek, Josef
    Styskala, Vitezslav
    Kijonka, Jaromir
    Miculka, Petr
    Zharkov, Yury I.
    PROCEEDINGS OF THE 10TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2009, 2009, : 308 - +
  • [38] Current Transformers' Saturation Detection and Compensation Based on Instantaneous Flux Density Calculations
    Fallahi, A.
    Ramezani, N.
    Ahmadi, I.
    AUTOMATIKA, 2016, 57 (04) : 1070 - 1078
  • [39] ALTERNATING CURRENT 50 HZ ELECTRIC TRACTION ON THE SOUTH AFRICAN RAILWAYS.
    ANON
    1982, V 80 (N 8): : 234 - 240
  • [40] Moisture effects on the electric strength of oil/pressboard insulation used in power transformers
    Krause, C
    Brupbacher, P
    Fehlmann, A
    Heinrich, B
    ICDL: 2005 IEEE International Conference on Dielectric Liquids, 2005, : 369 - 372