A study on a hybrid system of cable-stayed prestressed concrete bridge and steel suspension bridge

被引:0
|
作者
Takemura, H
Ohura, T
Onushi, M
Tanabe, T
机构
来源
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The span of cable-stayed prestressed concrete bridges combined with steel girder has been longer than 800m such as Tatara Ohashi and Normandy Bridge. But it is not expected that it will be longer than 2000m because of structural and economical problems. On the other hand, there are many steel suspension bridges with long span more than 1000m, and furthermore, there are some projects to construct bridges with very long span at straits in Japan. In such projects, it is said that their spans are more than 2000m. In this paper, the authors propose a hybrid system of cable-stayed prestressed concrete bridge and steel suspension bridge, which enables us to construct bridges with longer span and is expected to have an economical advantage compared with ordinary steel suspension bridge.
引用
收藏
页码:61 / 66
页数:6
相关论文
共 50 条
  • [1] CONVERSION OF A SUSPENSION BRIDGE INTO A CABLE-STAYED BRIDGE
    BUCKLAND, PG
    MORGENSTERN, BD
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 1991, 18 (02) : 273 - 281
  • [2] Dynamic investigation of a hybrid suspension and cable-stayed bridge
    Paultre, P
    Proulx, J
    Bégin, T
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2000, 29 (05): : 731 - 739
  • [3] Mechanical Analysis of Prestressed Concrete Partially Cable-Stayed Bridge with Corrugated Steel Webs
    Liu, Wenjuan
    Zhang, Fengping
    Li, Peifeng
    Zhang, Rui
    Wan, Shui
    [J]. PROCEEDINGS OF THE 2015 4TH INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING, 2016, 53 : 166 - 170
  • [4] Structural behavior of cable anchorage zones in prestressed concrete cable-stayed bridge
    Jo, BW
    Byun, YJ
    Tae, GH
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 2002, 29 (01) : 171 - 180
  • [5] The effect of cable loosening on seismic response of a prestressed concrete cable-stayed bridge
    Wu, Q
    Takahashi, K
    Nakamura, S
    [J]. JOURNAL OF SOUND AND VIBRATION, 2003, 268 (01) : 71 - 84
  • [6] Analysis on dynamic characteristics of partially cable-stayed prestressed concrete bridge
    Shangguan, Ping
    Fang, Zhen-Zheng
    Zhuo, Wei-Dong
    [J]. ADVANCES IN STRUCTURAL ENGINEERING:THEORY AND APPLICATIONS VOLS 1 AND 2, 2006, : 1336 - 1341
  • [7] AERODYNAMIC INSTABILITY OF PRESTRESSED CONCRETE CABLE-STAYED BRIDGE WITH NOISE BARRIER
    HONDA, A
    ITO, M
    KIMURA, H
    [J]. JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1992, 42 (1-3) : 1169 - 1180
  • [8] HEALTH MONITORING SYSTEM OF LONG-SPAN PRESTRESSED CONCRETE CABLE-STAYED BRIDGE
    Tu, Guangya
    Yan, Donghuang
    Chen, Changsong
    [J]. INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE PERFORMANCE OF BRIDGES AND STRUCTURES, 2010, : 196 - 200
  • [9] Seismic design of a steel-concrete hybrid cable-stayed bridge - the Shin-Minato bridge
    Yoshinaga, Hiroshi
    Ymanouchi, Tetsuya
    Goto, Yoshio
    Nagai, Masatsugu
    [J]. STEEL CONSTRUCTION-DESIGN AND RESEARCH, 2008, 1 (01): : 66 - U124
  • [10] Construction of the hybrid cable-stayed bridge
    Kim, D. G.
    Kwon, H. C.
    Lee, K. J.
    [J]. BRIDGE MAINTENANCE, SAFETY, MANAGEMENT AND LIFE-CYCLE OPTIMIZATION, 2010, : 3328 - 3333