Lymph node metastases of cutaneous melanoma: Diagnosis by B-scan and color Doppler sonography

被引:38
|
作者
Moehrle, M [1 ]
Blum, A [1 ]
Rassner, G [1 ]
Juenger, M [1 ]
机构
[1] Univ Tubingen, Dept Dermatol, D-72076 Tubingen, Germany
关键词
D O I
10.1016/S0190-9622(99)70004-6
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background: Sonography is a sensitive, noninvasive method that can be used to detect regional lymph node metastases. Color Doppler sonography (CDS) can supply further information on lymph node perfusion. Objective: We evaluated the usefulness of CDS for differentiating between benign lymphadenopathies and lymph node metastases of cutaneous melanoma. Methods: In a prospective study, reactive inflammatory lymph nodes (rLN) and lymph node metastases of cutaneous melanoma (mLN) were examined by sonography and CDS. Lymph node echogenicity and shape (length/depth ratio) were determined by sonography. The vascularization pattern of the lymph nodes was established with CDS. We recorded the Doppler frequency spectra at the hill of the lymph nodes and then calculated the resistance and pulsatility indices (RI, PT). Results: The echogenicity of the lymph node centers had a sensitivity of 96% and a specificity of 100%. The shape differed highly significantly between the two groups (P < .001). The criterion length/depth ratio < 2 had a sensitivity of 85% and specificity of 86%. Hilus vessels could be detected in 14 of 22 rLN (64%). These vessels, however, were not present in any of the metastases. The RI and the PI in detectable lymph node vessels differed between the two groups (RI: P < .05; PI: not significant), but because of the overlap between the two groups, these indices were of no diagnostic value. In the presence of 2 or more of the following 3 criteria: length/depth ratio < 2, hypoechoic center, and the absence of hilus vessels, diagnosis of metastasis of malignant melanoma had a sensitivity of 100% and a specificity of 96%. Conclusion: CDS improves the diagnostic accuracy of conventional sonography. The measurement of Doppler curves in lymph node vessels and the calculation of pulsatility and resistance indices, on the other hand, is time-consuming and seems to be of no diagnostic value.
引用
收藏
页码:703 / 709
页数:7
相关论文
共 50 条
  • [31] B-SCAN ULTRASOUND FOR CARDIAC DIAGNOSIS
    GEHRKE, J
    PRIDIE, RB
    BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (575): : 952 - 952
  • [32] B-SCAN ULTRASOUND IN DIAGNOSIS OF HYDRONEPHROSIS
    SANDERS, RC
    BEARMAN, S
    RADIOLOGY, 1973, 108 (02) : 375 - 382
  • [33] OCULAR DIAGNOSIS WITH B-SCAN ULTRASONOGRAPHY
    LINDE, CJ
    EPSTEIN, D
    JERNDAL, B
    ALGVERE, P
    ACTA OPHTHALMOLOGICA, 1977, 55 (05): : 879 - 879
  • [34] B-scan for the Diagnosis of Choroidal Diseases
    Yeh, Po-Ting
    JOURNAL OF MEDICAL ULTRASOUND, 2013, 21 (03) : 123 - 125
  • [35] High-Resolution Ultrasound Combined with Power Doppler Sonography Can Reduce the Number of Sentinel Lymph Node Biopsies in Cutaneous Melanoma
    Hinz, Torsten
    Wilsmann-Theis, Dagmar
    Buchner, Andrea
    Wenzel, Joerg
    Wendtner, Clemens-M.
    Bieber, Thomas
    Reinhard, Guenter
    Baumert, Jens
    Schmid-Wendtner, Monika-H.
    DERMATOLOGY, 2011, 222 (02) : 180 - 188
  • [36] Role of preoperative transvaginal sonography, color flow imaging, and Doppler waveform analysis in predicting lymph node metastases in patients with ovarian cancer
    Takac, I
    GYNECOLOGIC ONCOLOGY, 1998, 71 (02) : 211 - 218
  • [37] DOPPLER SONOGRAPHY IN OBSTETRICS COMPARISON BETWEEN SIMPLEX (CONTINUOUS OR PULSED) METHODS AND DUPLEX SYSTEM (COMBINATION OF B-SCAN AND PULSED DOPPLER)
    JORN, H
    FENDEL, H
    CHRIST, B
    ZEITSCHRIFT FUR GEBURTSHILFE UND PERINATOLOGIE, 1991, 195 (03): : 107 - 113
  • [38] Role of sonography in the diagnosis of axillary lymph node metastases in breast cancer:: A systematic review
    Alvarez, S
    Añorbe, E
    Alcorta, P
    López, F
    Alonso, I
    Cortés, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (05) : 1342 - 1348
  • [39] DIAGNOSIS AND TREATMENT CONTROL OF CHOROIDAL MELANOMAS - THE ROLE OF B-SCAN AND DOPPLER-TECHNIQUE
    GUTHOFF, R
    WINKLER, P
    HELMKE, K
    BERGER, R
    ACTA OPHTHALMOLOGICA, 1992, 70 : 59 - 61
  • [40] Colour Doppler ultrasonography in the diagnosis of axillary lymph node metastases in breast cancer
    Perre, CI
    Koot, VCM
    deHooge, P
    Weits, T
    Leguit, P
    BREAST, 1996, 5 (01): : 10 - 12