TEST-RETEST AND INTER-RATER RELIABILITY OF A METHOD TO MEASURE WRIST AND FINGER SPASTICITY

被引:50
|
作者
Gaverth, Johan [1 ,2 ]
Sandgren, Maria [3 ]
Lindberg, Pavel G. [1 ,3 ]
Forssberg, Hans [1 ,4 ]
Eliasson, Ann-Christin [1 ]
机构
[1] Karolinska Inst, Dept Women s & Childrens Hlth, SE-17176 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Psysiotherapy, Stockholm, Sweden
[3] Karolinska Inst, Dandeiyd Hosp, Dept Clin Sci Rehabil Med, Stockholm, Sweden
[4] CNRS, Ctr Etudes Sensorimotricite, UMR 8194, Paris, France
基金
瑞典研究理事会;
关键词
hand; medical instrument; outcome assessment; muscle spasticity; stroke; upper extremity; wrist; MODIFIED ASHWORTH SCALE; SPINAL-CORD-INJURY; MUSCLE; POSTSTROKE; STROKE; STIMULATION; STRETCH; MODEL; ELBOW;
D O I
10.2340/16501977-1160
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To describe the reliability of an instrument (Neuro Flexor) designed to be used in the clinic for quantification of the relative contribution of spasticity, elasticity and viscosity to resistance during passive wrist movements. Design: A test-retest and inter-rater reliability study. Subjects: A convenience sample of 34 adults with chronic stroke with spasticity in the hand, and a reference group of 10 healthy persons. Methods: Two raters assessed the participants with the Neuro-Flexor. Elastic, viscous and neural components of passive movement resistance were quantified at the wrist. Test-retest and inter-rater intraclass correlation coefficient (ICC2.1) were calculated for each component for both raters and two sessions. Degree of measurement error was evaluated using the coefficient of variation and the repeatability coefficient. Results: Reliability was high for the neural component (test-retest: 0.90-0.96; inter-rater: 0.90-0.94), fair to good for the elastic component (test-retest: 0.79-0.88; inter-rater: 0.76-0.76), and fair to high for the viscous component (test-retest: 0.88-0.90; inter-rater: 0.75-0.80). Based on test-retest data, the coefficients of variation for the neural, elastic and viscous components were 25%, 26% and 16%, respectively, and the repeatability coefficients were 1.798, 1.897 and 1.404, respectively. Conclusion: The NeuroFlexor instrument is a reliable measure of spasticity and of muscle elasticity and viscosity in individuals with wrist and finger muscle resistance to passive stretch after stroke.
引用
收藏
页码:630 / 636
页数:7
相关论文
共 50 条
  • [21] Investigation of inter-rater and test-retest reliability of Y balance test in college students with flexible flatfoot
    Zheng, Yalin
    Feng, Renzhi
    Hu, Weiyin
    Huang, Peng
    [J]. BMC SPORTS SCIENCE MEDICINE AND REHABILITATION, 2024, 16 (01)
  • [22] Adolescents Semistructured Interview (ASI):: Characteristics and inter-rater, and test-retest reliability study.
    de la Peña, F
    Patiño, M
    Mendizabal, A
    Cortés, J
    Cruz, E
    Ulloa, RE
    Villamil, V
    Lara, MC
    [J]. SALUD MENTAL, 1998, 21 (06) : 11 - 18
  • [23] Diagnostic interview for genetic studies (DIGS): inter-rater and test-retest reliability of the French version
    Preisig, M
    Fenton, BT
    Matthey, ML
    Berney, A
    Ferrero, F
    [J]. EUROPEAN ARCHIVES OF PSYCHIATRY AND CLINICAL NEUROSCIENCE, 1999, 249 (04) : 174 - 179
  • [24] Diagnostic interview for genetic studies (DIGS): inter-rater and test-retest reliability of the French version
    M. Preisig
    Brenda T. Fenton
    Marie-Louise Matthey
    Alexandre Berney
    François Ferrero
    [J]. European Archives of Psychiatry and Clinical Neuroscience, 1999, 249 : 174 - 179
  • [25] Test-retest, intra- and inter-rater reliability of the reactive balance test in patients with chronic ankle instability
    Maricot, Alexandre
    Lathouwers, Elke
    Verschueren, Jo
    De Pauw, Kevin
    Meeusen, Romain
    Roelands, Bart
    Tassignon, Bruno
    [J]. FRONTIERS IN NEUROLOGY, 2024, 15
  • [26] TEST-RETEST AND INTER-RATER RELIABILITY OF THE 20-METER AMBULATION TEST IN PATIENTS WITH PARKINSON?S DISEASE
    Hutin, Emilie
    Ghedira, Mouna
    Mardale, Valentina
    Boutou, Mina
    Santiago, Tharaga
    Joudoux, Sandrine
    Gault-Colas, Caroline
    Gracies, Jean-Michel
    Bayle, Nicolas
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2023, 55
  • [27] Test-retest and inter-rater reliability for the Comprehensive Developmental Inventory for Infants and Toddlers diagnostic and screening tests
    Liao, HF
    Pan, YL
    [J]. EARLY HUMAN DEVELOPMENT, 2005, 81 (11) : 927 - 937
  • [28] Diagnostic Interview for Genetic Studies (DIGS):: Inter-rater and test-retest reliability and validity in a Spanish population
    Roca, Miguel
    Martin-Santos, Rocio
    Saiz, Jeronimo
    Obiols, Jordi
    Serrano, Maria J.
    Torrens, Marta
    Subira, Susana
    Gili, Margalida
    Navines, Ricard
    Ibanez, Angela
    Nadal, Marcos
    Barrantes, Nieves
    Canellas, Francesca
    [J]. EUROPEAN PSYCHIATRY, 2007, 22 (01) : 44 - 48
  • [29] Improving the test-retest and inter-rater reliability for stretch reflex measurements using an isokinetic device in stroke patients with mild to moderate elbow spasticity
    Sin, Minki
    Kim, Won-Seok
    Cho, Kyujin
    Cho, Sungmin
    Paik, Nam-Jong
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2018, 39 : 120 - 127
  • [30] Test-Retest reliability, construct validity, and inter-rater agreement of the brief Dark Triad measurements.
    Dragostinov, Y.
    Peh, I.
    Booth, T.
    Mottus, R.
    [J]. PERSONALITY AND INDIVIDUAL DIFFERENCES, 2024, 221