Development and application of a multi-axis dynamometer for measuring grip force

被引:4
|
作者
Irwin, C. B. [1 ]
Towles, J. D. [2 ]
Radwin, R. G. [3 ]
机构
[1] Design Concepts Inc, Madison, WI USA
[2] Univ Wisconsin, Dept Mech Engn, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Ind & Syst Engn, Madison, WI 53715 USA
关键词
2D grip force; multi-axis grip dynamometer; handle design; CYLINDRICAL HANDLE; FINGER FORCES; STRENGTH; DISABILITY; DIAMETERS; ADULTS; SIZE;
D O I
10.1080/00140139.2013.847212
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Objective: This paper describes the development and application of a novel multi-axis hand dynamometer for quantifying 2D grip force magnitude and direction in the flexion-extension plane of the fingers. Methods: A three-beam reconfigurable form dynamometer, containing two active beams for measuring orthogonal forces and moments regardless of point of force application, was designed, fabricated and tested. Maximum grip exertions were evaluated for 16 subjects gripping cylindrical handles varying in diameter. Results: Mean grip force magnitudes were 231 N (SD=67.7 N), 236 N (72.9 N), 208 N (72.5 N) and 158 N (45.7 N) for 3.81cm, 5.08cm, 6.35cm and 7.62cm diameter handles, respectively. Grip force direction rotated clockwise and the centre of pressure moved upward along the handle as handle diameter increased. Conclusions: Given that the multi-axis dynamometer simultaneously measures planar grip force magnitude and direction, and centre of pressure along the handle, this novel sensor design provides more grip force characteristics than current sensor designs that would improve evaluation of grip characteristics and model-driven calculations of musculoskeletal forces from dynamometer data. Practitioner Summary: The dynamometer was designed to isolate and describe force vectors produced by the finger segments. It may be particularly more suitable than current grip force dynamometers for improving model-based estimations of musculoskeletal forces and stresses that could ultimately improve ergonomic design of devices that interface with the hand.
引用
收藏
页码:1841 / 1849
页数:9
相关论文
共 50 条
  • [21] Design of a Motor Bracket Multi-Axis Force/Torque Sensor
    Chen, Chung-Sheng
    Lin, Thomas Chang-Hao
    Lin, Tzu-Han
    Lin, Pei-Chun
    [J]. 2016 13TH INTERNATIONAL CONFERENCE ON UBIQUITOUS ROBOTS AND AMBIENT INTELLIGENCE (URAI), 2016, : 305 - 307
  • [22] Multi-axis force measurements of polymer friction stir welding
    Eslami, Shayan
    Mourao, Luis
    Viriato, Nuno
    Tavares, Paulo J.
    Moreira, P. M. G. P.
    [J]. JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2018, 256 : 51 - 56
  • [23] A Multi-Axis Force Measurement System for a Space Docking Mechanism
    Liu, Gangfeng
    Li, Changle
    Xie, Zenghui
    [J]. PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MATERIAL, MECHANICAL AND MANUFACTURING ENGINEERING, 2015, 27 : 1416 - 1420
  • [24] PREDICTION OF MULTI-AXIS SUPERELASTIC STRESSES DURING MEASURING OF ELONGATION
    PEITER, A
    [J]. METALL, 1975, 29 (08): : 801 - 807
  • [25] Dynamic decoupling and compensating methods of multi-axis force sensors
    Xu, KJ
    Li, C
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2000, 49 (05) : 935 - 941
  • [26] Multi-axis force sensors: A state-of-the-art review
    Templeman, Jack O.
    Sheil, Brian B.
    Sun, Tong
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2020, 304
  • [27] Calibration and decoupling of multi-axis robotic Force/Moment sensors
    Liang, Qiaokang
    Wu, Wanneng
    Coppola, Gianmarc
    Zhang, Dan
    Sun, Wei
    Ge, Yunjian
    Wang, Yaonan
    [J]. ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2018, 49 : 301 - 308
  • [28] Development of a dynamometer for measuring the isometric force of the pelvic floor musculature
    Dumoulin, C
    Bourbonnais, D
    Lemieux, MC
    [J]. NEUROUROLOGY AND URODYNAMICS, 2003, 22 (07) : 648 - 653
  • [29] Utilization of modal analysis in design of multi-axis force sensor
    Draisey, S
    Richmond, D
    [J]. IMAC-XVIII: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, PROCEEDINGS, 2000, 4062 : 1485 - 1490
  • [30] Application of Dynamometer Trailer SRT-4 for Measuring Tyre Wet Grip Index
    Pokorski, J.
    Renski, A.
    Sar, H.
    [J]. TRANSPORT MEANS 2015, PTS I AND II, 2015, : 79 - 82