A Numerical Analysis of the Cooling Performance of a Hybrid Personal Cooling System (HPCS): Effects of Ambient Temperature and Relative Humidity

被引:19
|
作者
Xu, Pengjun [1 ]
Kang, Zhanxiao [2 ]
Wang, Faming [3 ]
Udayraj [4 ]
机构
[1] Xiamen Univ Technol, Sch Design Art, Xiamen 361024, Peoples R China
[2] Hong Kong Polytech Univ, Hung Hom, Hong Kong 999007, Peoples R China
[3] Cent South Univ, Sch Architecture & Art, Changsha 410083, Peoples R China
[4] Indian Inst Technol Bhilai, Dept Mech Engn, Chhattisgarh 492015, India
基金
中国国家自然科学基金;
关键词
personal cooling system; heat and mass transfer; ambient temperature; relative humidity; phase change materials; thermal management; IMPROVE THERMAL COMFORT; PHASE-CHANGE MATERIALS; HEAT-STRESS; HOT; GARMENTS; VEST; PREDICTION; DESIGN; HEALTH; STRAIN;
D O I
10.3390/ijerph17144995
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hybrid personal cooling systems (HPCS) incorporated with ventilation fans and phase change materials (PCMs) have shown its superior capability for mitigating workers' heat strain while performing heavy labor work in hot environments. In a previous study, the effects of thermal resistance of insulation pads, and latent heat and melting temperature of PCMs on the HPCS's thermal performance have been investigated. In addition to the aforementioned factors, environmental conditions, i.e., ambient temperature and relative humidity, also significantly affect the thermal performance of the HPCS. In this paper, a numerical parametric study was performed to investigate the effects of the environmental temperature and relative humidity (RH) on the thermal management of the HPCS. Five levels of air temperature under RH = 50% (i.e., 32, 34, 36, 38 and 40 degrees C) and four levels of environmental RH at two ambient temperatures of 36 and 40 degrees C were selected (i.e., RH = 30, 50, 70 and 90%) for the numerical analysis. Results show that high environmental temperatures could accelerate the PCM melting process and thereby weaken the cooling performance of HPCS. In the moderately hot environment (36 degrees C), HPCS presented good cooling performance with the maximum core temperature at around 37.5 degrees C during excise when the ambient RH <= 70%, whereas good cooling performance could be only seen under RH <= 50% in the extremely hot environment (40 degrees C). Thus, it may be concluded that the maximum environmental RH under which the HPCS exhibiting good cooling performance decreases with an increase in the environmental temperature.
引用
收藏
页码:1 / 19
页数:19
相关论文
共 50 条
  • [21] Performance characteristic of hybrid cooling system based on cooling pad and evaporator
    Yoon, J. I.
    Son, C. H.
    Choi, K. H.
    Kim, Y. B.
    Sung, Y. H.
    Roh, S. J.
    Kim, Y. M.
    Seol, S. H.
    8TH TSME-INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (TSME-ICOME 2017), 2018, 297
  • [22] Numerical analysis of relative humidity distribution in polymer electrolyte fuel cell stack including cooling water
    Inoue, Gen
    Yoshimoto, Takashi
    Matsukuma, Yosuke
    Minemoto, Masaki
    Itoh, Hideki
    Tsurumaki, Shigeru
    JOURNAL OF POWER SOURCES, 2006, 162 (01) : 81 - 93
  • [23] INVESTIGATION OF THE EFFECTIVENESS OF THE FAN-PAD COOLING SYSTEM AND THE HORIZONTAL TEMPERATURE AND RELATIVE HUMIDITY CHANGES IN THE GREENHOUSE
    Boyaci, Sedat
    FRESENIUS ENVIRONMENTAL BULLETIN, 2018, 27 (12B): : 9755 - 9761
  • [24] Numerical analysis of the cooling performance of wet cooling tower with cross wall
    Zhao, Yuan-Bin
    Sun, Feng-Zhong
    Wang, Kai
    Chen, You-Liang
    Gao, Ming
    Wang, Hong-Guo
    Shi, Yue-Tao
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2009, 29 (08): : 6 - 13
  • [25] LAKE TEMPERATURE DYNAMICS IN HYBRID COOLING SYSTEM
    STURM, TW
    FULFORD, JM
    FAY, KJ
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1983, 109 (03): : 668 - 684
  • [26] Numerical analysis of a near-room-temperature magnetic cooling system
    Ezan, Mehmet Akif
    Ekren, Orhan
    Metin, Cagri
    Yilanci, Ahmet
    Biyik, Emrah
    Kara, Salih Murat
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 75 : 262 - 275
  • [27] Cryogen spray cooling in laser dermatology: Effects of ambient humidity and frost formation
    Majaron, B
    Kimel, S
    Verkruysse, W
    Aguilar, G
    Pope, R
    Svaasand, LO
    Lavernia, EJ
    Nelson, JS
    LASERS IN SURGERY AND MEDICINE, 2001, 28 (05) : 469 - 476
  • [28] Experimental and Statistical Analysis of Relative Humidity and Temperature of Moist Air in a Flat Plate Multi-Layer Desiccant Cooling System
    Sharma, Akash
    Kaushal, Rajneesh
    Energy Sources, Part A: Recovery, Utilization and Environmental Effects, 2025, 47 (01) : 7047 - 7064
  • [29] Effect of cooling strategies on overall performance of a hybrid personal cooling system incorporated with phase change materials (PCMs) and electric fans
    Wang, Faming
    Ke, Ying
    Udayraj
    Yang, Bin
    Xu, Pengjun
    Noor, Nuruzzaman
    JOURNAL OF THERMAL BIOLOGY, 2020, 92
  • [30] Numerical analysis on effects of coolant swirling motion on film cooling performance
    Yang, Xing
    Liu, Zhao
    Liu, Zhansheng
    Feng, Zhenping
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 90 : 1082 - 1089