Reproducibility of Nerve Fiber Layer Thickness Measurements Using 3D Fourier-Domain OCT

被引:83
|
作者
Menke, Marcel N. [1 ]
Knecht, Pascal [1 ]
Sturm, Veit [1 ]
Dabov, Simeon [2 ]
Funk, Jens [1 ]
机构
[1] Univ Zurich USZ, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[2] Univ Munster, Sch Med, Munster, Germany
关键词
D O I
10.1167/iovs.07-1435
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. Conventional time-domain optical coherence tomography (OCT) has been shown to provide reproducible retinal nerve fiber layer (RNFL) measurements. Recently, high-speed, high-resolution Fourier-domain 3D-OCT has been introduced to improve OCT quality. It can provide 6-mm(2) high-density scans to provide RNFL thickness measurements. The purpose of this study was to test the reproducibility of 3D-OCT RNFL thickness measurements in healthy volunteers. METHODS. Thirty-eight eyes were included in the study. High-density 6-mm(2) 3D scans were registered by two independent operators. RNFL thickness was calculated for eight areas corresponding to the ETDRS areas and for two ring areas. The ETDRS grid was centered on the optic disc. Intraclass correlation coefficients (ICC) and coefficients of variation (COV) were calculated. Interobserver reproducibility was visualized by using Bland-Altman analysis. RESULTS. Intrasession reproducibility was good with a mean ICC of 0.90. The mean COV for operator 1 and 2 was 4.2% and 4%, respectively (range, 1.9%-6.7%). Highest reproducibility was found for the two ring areas and the superior and inferior quadrants. Mean differences in RNFL thickness measurements for ring 1 and 2 between operator 1 and 2 were 0.9 mu m (limits of agreement, -11.4 to +9.6 mu m) and 0.1 mu m (limits of agreement -4.1 to +3.9 mu m), respectively. CONCLUSIONS. 3D-OCT RNFL thickness measurements in healthy volunteers showed good intra- and interobserver reproducibility. 3D-OCT provides more RNFL thickness information compared to conventional time-domain OCT measurements and may be useful for the management of glaucoma and other optic neuropathies. (Invest Ophthalmol Vis Sci. 2008;49:5386-5391) DOI: 10.1167/iovs.07-1435
引用
收藏
页码:5386 / 5391
页数:6
相关论文
共 50 条
  • [1] Intra and interoperator reproducibility of retinal nerve fibre and macular thickness measurements using Cirrus Fourier-domain OCT
    Garcia-Martin, Elena
    Pinilla, Isabel
    Idoipe, Miriam
    Fuertes, Isabel
    Pueyo, Victoria
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (01) : E23 - E29
  • [2] The Effect of Image Quality on the Reliability of Nerve Fiber Layer Measurements with Fourier-Domain OCT
    Tan, Ou
    Zhang, Xinbo
    Loewen, Nils
    Schuman, Joel
    Greenfield, David
    Varma, Rohit
    Huang, David
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [3] Retinal nerve fiber layer thickness measurement using 3D fourier - domain optical coherence tomography (OCT)
    Cvenkel, Barbara
    Kontestabile, Alenka Sket
    [J]. ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2010, 79 : 96 - 103
  • [4] Retinal nerve fiber layer analysis in RP patients using Fourier-domain OCT
    Walia, Saloni
    Fishman, Gerald A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) : 3525 - 3528
  • [5] Fourier-Domain OCT in Multiple Sclerosis Patients: Reproducibility and Ability to Detect Retinal Nerve Fiber Layer Atrophy
    Garcia-Martin, Elena
    Pueyo, Victoria
    Pinilla, Isabel
    Ara, Jose-Ramon
    Martin, Jesus
    Fernandez, Javier
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (07) : 4124 - 4131
  • [6] Reproducibility of peripapillary retinal nerve fiber layer thickness measurements using Spectral Domain OCT in Brazilian patients
    Toscano, Daniela Araujo
    de Avila, Marcos Pereira
    Catai Chalita, Maria Regina
    [J]. ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (05) : 320 - 323
  • [7] Reproducibility of retinal thickness measurements in patients with age-related macular degeneration using 3D Fourier-domain optical coherence tomography (OCT) (Topcon 3D-OCT 1000)
    Menke, Marcel N.
    Dabov, Simeon
    Knecht, Pascal
    Sturm, Veit
    [J]. ACTA OPHTHALMOLOGICA, 2011, 89 (04) : 346 - 351
  • [8] Retinal nerve fibre layer thickness analysis in X-linked retinoschisis using Fourier-domain OCT
    Genead, M. A.
    Pasadhika, S.
    Fishman, G. A.
    [J]. EYE, 2009, 23 (05) : 1020 - 1026
  • [9] Retinal nerve fibre layer thickness analysis in X-linked retinoschisis using Fourier-domain OCT
    M A Genead
    S Pasadhika
    G A Fishman
    [J]. Eye, 2009, 23 : 1019 - 1027
  • [10] Reproducibility of nerve fiber layer thickness measurements
    Weinreb, RN
    Zangwill, L
    [J]. OPHTHALMOLOGY, 1997, 104 (10) : 1530 - 1531