Active and Reactive Power Control of Synchronous Generator for the Realization of a Virtual Power Plant

被引:0
|
作者
Khan, H. A. [1 ]
Bargiev, P. [1 ]
Sreeram, V. [1 ]
Iu, H. H. C.
Fernando, T. L. [1 ]
Mishra, Y.
机构
[1] Univ Western Australia, 35 Stirling Highway, Perth, WA 6009, Australia
关键词
Active & Reactive Power Control; Medium Voltage Transmission Line; Medium Length Transmission line; Phase Shift; Rotational Transformation; R/X Ratio; Virtual Power Plant; Distributed Power Generation; Hydroelectric Power Generation;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a novel power control strategy that decouples the active and reactive power for a synchronous generator connected to a power network. The proposed control paradigm considers the capacitance of the transmission line along with its resistance and reactance as-well. Moreover the proposed controller takes into account all cases of R-X relationships, thus allowing it to function in Virtual Power Plant (VPP) structures which operate at both medium voltage (MV) and low voltage (LV) levels. The independent control of active and reactive power is achieved through rotational transformations of the terminal voltages and currents at the synchronous generator's output. This paper details the control technique by first presenting the mathematical and electrical network analysis of the methodology and then successfully implementing the control using MATLAB-SIMULINK simulation.
引用
收藏
页码:1204 / 1210
页数:7
相关论文
共 50 条
  • [31] Distributed Power Generation Virtual Synchronous Generator Control Design and Analysis
    Tang, Shuai
    Mao, Longbo
    Wang, Wenqiang
    Geng, Haoxiang
    Wang, Weijun
    2021 PROCEEDINGS OF THE 40TH CHINESE CONTROL CONFERENCE (CCC), 2021, : 5822 - 5829
  • [32] Unbalanced Control Strategy of Improved Virtual Synchronous Generator in Power Grid
    Liang, Dong
    Qin, Chaoyun
    Zong, Jin
    Wu, Xichun
    Mei, Jun
    Wang, Bingbing
    2018 IEEE 8TH ANNUAL INTERNATIONAL CONFERENCE ON CYBER TECHNOLOGY IN AUTOMATION, CONTROL, AND INTELLIGENT SYSTEMS (IEEE-CYBER), 2018, : 1311 - 1316
  • [33] Adjustment of Active and Reactive Power of Synchronous Generator in Grid-connected Operation
    Sun, Huiqiang
    2019 5TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND MATERIAL APPLICATION, 2020, 440
  • [34] Active Power Allocation of Virtual Synchronous Generator Considering Multiple Operating Scenarios
    Rahman, Fathin Saifur
    Kerdphol, Thongchart
    Watanabe, Masayuki
    Mitani, Yasunori
    2018 5TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2018,
  • [35] Damping strategy of virtual synchronous generator based on active power deviation feedforward
    Li Y.
    Qi R.
    Deng F.
    Lin H.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2022, 52 (04): : 816 - 824
  • [36] Comprehensive perspective on virtual inductor for improved power decoupling of virtual synchronous generator control
    Wen, Tiliang
    Zou, Xudong
    Zhu, Donghai
    Guo, Xiang
    Peng, Li
    Kang, Yong
    IET RENEWABLE POWER GENERATION, 2020, 14 (04) : 485 - 494
  • [37] Robust control of a synchronous power generator
    Kelemen, M
    Okou, AF
    Akhrif, O
    Dessaint, LA
    NONLINEAR CONTROL IN THE YEAR 2000, VOL 1, 2000, 258 : 583 - 596
  • [38] Modelling, synchronisation, and implementation of the virtual synchronous generator: a study of its reactive power handling
    Ramirez, Juan M.
    Torres Montalvo, Emmanuel
    Ibarra Nuno, Cesar
    ELECTRICAL ENGINEERING, 2020, 102 (03) : 1605 - 1619
  • [39] Parameter Design of Reactive Power-Voltage Loop for Robust Virtual Synchronous Generator
    Liao L.
    Zhang C.
    Liu N.
    Chen X.
    Chen S.
    Liu Q.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (12): : 136 - 142
  • [40] Modelling, synchronisation, and implementation of the virtual synchronous generator: a study of its reactive power handling
    Juan M. Ramirez
    Emmanuel Torres Montalvo
    Cesar Ibarra Nuño
    Electrical Engineering, 2020, 102 : 1605 - 1619