Validation of a Monte Carlo simulation of the Philips Allegro/GEMINI PET systems using GATE

被引:117
|
作者
Lamare, F [1 ]
Turzo, A [1 ]
Bizais, Y [1 ]
Le Rest, CC [1 ]
Visvikis, D [1 ]
机构
[1] Univ Bretagne Occidentale, CHU Morvan, INSERM U650, Lab Traitement Informat Med, F-29609 Brest, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2006年 / 51卷 / 04期
关键词
D O I
10.1088/0031-9155/51/4/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A newly developed simulation toolkit, GATE (Geant4 Application for Tomographic Emission), was used to develop a Monte Carlo simulation of a fully three-dimensional (3D) clinical PET scanner. The Philips Allegro/GEMINI PET systems were simulated in order to (a) allow a detailed study of the parameters affecting the system's performance under various imaging conditions, (b) Study the optimization and quantitative accuracy of emission acquisition protocols for dynamic and static imaging, and (c) further validate the potential of GATE for the Simulation of clinical PET systems. A model of the detection system and its geometry was developed. The accuracy of the developed detection model was tested through the comparison of simulated and measured results obtained with the Allegro/GEMINI systems for a number of NEMA NU2-2001 performance protocols including spatial resolution, sensitivity and scatter fraction. In addition, in approximate model of the system's dead time at the level of detected single events and coincidences was developed in an attempt to simulate the count rate related performance characteristics of the scanner. The developed dead-time model was assessed under different imaging conditions using the Count rate loss and noise equivalent Count rates performance protocols of standard and modified NEMA NU2-2001 (whole body imaging conditions) and NEMA NU2-1994 (brain imaging conditions) comparing simulated with experimental measurements obtained with the Allegro/GEMINI PET systems. Finally,a reconstructed image quality protocol was used to assess the overall performance of the developed model. An agreement of < 3% was obtained in scatter fraction, with a difference between 4% and 10% in the true and random coincidence Count rates respectively, throughout a range of activity concentrations and under various imaging conditions, resulting in < 8% differences between simulated and measured noise equivalent Count rates performance. Finally, the image quality validation Study revealed a good agreement in signal-to-noise ratio and contrast recovery coefficients fora number of different volume spheres and two different (clinical level based) tumour-to-background ratios. In conclusion, these results support the accurate modelling of the Philips Allegro/GEMINI PET systems using GATE in combination with a dead-time model for the signal flow description, which leads to an agreement of < 10% in coincidence count rates under different imaging conditions and clinically relevant activity concentration levels.
引用
收藏
页码:943 / 962
页数:20
相关论文
共 50 条
  • [41] Monte Carlo simulations of a scintillation camera using GATE: validation and application modelling
    Staelens, S
    Strul, D
    Santin, G
    Vandenberghe, S
    Koole, M
    D'Asseler, Y
    Lemahieu, I
    van de Walle, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (18): : 3021 - 3042
  • [42] Comparison of Single-Scatter Simulation and Monte Carlo Single-Scatter Simulation on Philips Ingenuity TF PET/MR
    Teuho, Jarmo
    Johansson, Jarkko
    Linden, Jani
    Saunavaara, Virva
    Teras, Mika
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [43] Validation of a simultaneous PET/MR system model for PET simulation using GATE
    Florian Monnier
    Hadi Fayad
    Julien Bert
    Holger Schmidt
    Dimitris Visvikis
    [J]. EJNMMI Physics, 2 (Suppl 1)
  • [44] Full modelling of the MOSAIC animal PET system based on the GATE Monte Carlo simulation code
    Merheb, C.
    Petegnief, Y.
    Talbot, J. N.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (03): : 563 - 576
  • [45] Preclinical voxel-based dosimetry through GATE Monte Carlo simulation using PET/CT imaging of mice
    Gupta, Arun
    Lee, Min Sun
    Kim, Joong Hyun
    Park, Sohyeon
    Park, Hyun Soo
    Kim, Sang Eun
    Lee, Dong Soo
    Lee, Jae Sung
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (09):
  • [46] Development and Validation of a Monte Carlo Simulation Workflow for a Total-Body PET Scanner
    Pommranz, C.
    Elmoujarkach, E.
    Cabello, J.
    Lan, W.
    Rafecas, M.
    Mannheim, J.
    Linder, P.
    Santangelo, A.
    la Fougere, C.
    Pichler, B.
    Schmidt, F.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S690 - S691
  • [47] Towards a standardization of the description and validation of Monte Carlo simulation codes in SPECT and PET.
    Buvat, I
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 207P - 207P
  • [48] MONTE-CARLO SIMULATION FOR PROTON THERAPY MONITORING USING PET
    Ty, C. Van Ngoc
    De Marzi, L.
    Jan, S.
    Lestand, L.
    Ferrand, R.
    Comtat, C.
    Trebossen, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S527 - S528
  • [49] Assessment of the Mosaic animal PET system response using list-mode data for validation of GATE Monte Carlo modelling
    Merheb, Charbel
    Nicol, Stan
    Petegnief, Yolande
    Talbot, Jean-Noel
    Buvat, Irene
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 220 - 224
  • [50] Validation of GATE Monte Carlo code for simulation of proton therapy using National Institute of Standards and Technology library data
    Zarifi, Shiva
    Ahangari, Hadi Taleshi
    Jia, Sayyed Bijan
    Tajik-Mansoury, Mohammad Ali
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (01) : 38 - 45