Whole-body motion correction in 13N-ammonia myocardial perfusion imaging using positron emission tracking

被引:0
|
作者
Manwell, Spencer [1 ,2 ]
Klein, Ran [3 ]
deKemp, Robert [2 ]
Xu, Tong [1 ]
机构
[1] Carleton Univ, Dept Phys, Ottawa, ON, Canada
[2] Univ Ottawa, Inst Heart, Natl PET Ctr, Ottawa, ON, Canada
[3] Ottawa Hosp, Div Nucl Med, Ottawa, ON, Canada
关键词
Positron Emission Tomography; Computed Tomography; Cardiology; Motion Correction; PATIENT MOTION; STRESS; RB-82; FLOW;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Patient motion during positron emission tomography (PET) studies leads to degradation of image quality. Not only does patient motion lead to blurring of regions of tracer uptake but it can also lead to mis-alignment artifacts associated with spatial mis-registration between the emission and transmission data used for attenuation correction. In this study we examine the benefits of a three-dimensional whole-body motion correction algorithm based on the use of tracking external radioactive markers placed on the patient. We used the positron emission tracking (PeTrack) algorithm to estimate translational patient motion for three patients who underwent 13N-ammonia myocardial perfusion imaging studies at rest and stress. PeTrack was used to identify instances of whole-body patient motion and its extent with respect to a reference position. This information was used to bin the raw list-mode data based on patient-motion amplitudes. The resulting set of gated emission data were reconstructed after using the PeTrack data to rigidly align the attenuation image to each gate. The final set of images were then re-aligned to the reference position. The weighted average of the individual gated images produces the final motion-corrected static image. This approach was evaluated by comparing the relative perfusion in the three arterial regions of the left-ventricular (LV) polar maps. Additionally, regional LV wall thickness and blood pool volume were measured. Whole-body motion in this small sample was limited and largely returned to the reference position. When considering rest and stress acquisitions, no statistically significant differences were observed for any of the metrics. LV wall thicknesses were significantly reduced after motion correction for the stress cases which exhibited the greatest motion. The benefits of motion correction may not be realized unless the extent of whole-body patient motion is large and/or non- returning. Our study demonstrated successful motion tracking using PeTrack, but this work must be extended to include more cases with more severe motion is indicated.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Feasibility of exercise treadmill 13N-ammonia positron emission tomography myocardial perfusion imaging using an off-site cyclotron
    Daniel R. Harland
    Patrycja Z. Galazka
    Jerry Rasmussen
    Debra Mahlum
    Janelle Falk
    Steven C. Port
    Journal of Nuclear Cardiology, 2022, 29 : 938 - 945
  • [2] Duration of adenosine-induced myocardial hyperaemia: insights from quantitative 13N-ammonia positron emission tomography myocardial perfusion imaging
    Garefa, Chrysoula
    Sager, Dominik F.
    Heiniger, Pascal S.
    Markendorf, Susanne
    Albertini, Tobia
    Jurisic, Stjepan
    Gajic, Marko
    Gebhard, Catherine
    Benz, Dominik C.
    Pazhenkottil, Aju P.
    Giannopoulos, Andreas A.
    Kaufmann, Philipp A.
    Slomka, Piotr J.
    Buechel, Ronny R.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (10) : 1367 - 1373
  • [3] Whole-body motion correction in cardiac PET/CT using Positron Emission Tracking: A phantom validation study
    Manwell, Spencer
    Klein, Ran
    deKemp, Robert
    Xu, Tong
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [4] Myocardial perfusion imaging with 13N-Ammonia PET is a strong predictor for outcome
    Fiechter, Michael
    Gebhard, Catherine
    Ghadri, Jelena R.
    Fuchs, Tobias A.
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Herzog, Bernhard A.
    Altorfer, Ulrich
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 167 (03) : 1023 - 1026
  • [5] Radiomics for the detection of diffusely impaired myocardial perfusion: A proof-of-concept study using 13N-ammonia positron emission tomography
    Ganna Degtiarova
    Chrysoula Garefa
    Reto Boehm
    Domenico Ciancone
    Daniel Sepulcri
    Catherine Gebhard
    Andreas A. Giannopoulos
    Aju P. Pazhenkottil
    Philipp A. Kaufmann
    Ronny R. Buechel
    Journal of Nuclear Cardiology, 2023, 30 : 1474 - 1483
  • [6] Sex differences in the long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography
    Gebhard, Catherine
    Fiechter, Michael
    Herzog, Bernhard A.
    Lohmann, Christine
    Bengs, Susan
    Treyer, Valerie
    Messerli, Michael
    Benz, Dominik C.
    Giannopoulos, Andreas A.
    Grani, Christoph
    Pazhenkottil, Aju P.
    Buechel, Ronny R.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 (11) : 1964 - 1974
  • [7] Radiomics for the detection of diffusely impaired myocardial perfusion: A proof-of-concept study using 13N-ammonia positron emission tomography
    Degtiarova, Ganna
    Garefa, Chrysoula
    Boehm, Reto
    Ciancone, Domenico
    Sepulcri, Daniel
    Gebhard, Catherine
    Giannopoulos, Andreas A.
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (04) : 1474 - 1483
  • [8] Sex differences in the long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography
    Catherine Gebhard
    Michael Fiechter
    Bernhard A. Herzog
    Christine Lohmann
    Susan Bengs
    Valerie Treyer
    Michael Messerli
    Dominik C. Benz
    Andreas A. Giannopoulos
    Christoph Gräni
    Aju P. Pazhenkottil
    Ronny R. Buechel
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2018, 45 : 1964 - 1974
  • [9] Correlation of apical left ventricular wall thickness and 13N-ammonia uptake in myocardial perfusion positron emission tomography
    Steffen, D. A.
    Grossmann, M.
    Giannopoulos, A. A.
    Messerli, M.
    Kaufmann, P. A.
    Buechel, R. R.
    EUROPEAN HEART JOURNAL, 2017, 38 : 624 - 624
  • [10] Integrated Myocardial Perfusion Imaging Diagnostics Improve Detection of Functionally Significant Coronary Artery Stenosis by 13N-ammonia Positron Emission Tomography
    Lee, Joo Myung
    Kim, Chee Hae
    Koo, Bon-Kwon
    Hwang, Doyeon
    Park, Jonghanne
    Zhang, Jinlong
    Tong, Yaliang
    Jeon, Ki-Hyun
    Bang, Ji-In
    Suh, Minseok
    Paeng, Jin Chul
    Cheon, Gi Jeong
    Na, Sang-Hoon
    Ahn, Jung-Min
    Park, Seung-Jung
    Kim, Hyo-Soo
    CIRCULATION-CARDIOVASCULAR IMAGING, 2016, 9 (09)