Nerve ultrasound in neurofibromatosis type 1: A follow-up study

被引:6
|
作者
Telleman, Johan A. [1 ]
Stellingwerff, Menno D. [1 ]
Brekelmans, Geert J. [1 ]
Visser, Leo H. [1 ]
机构
[1] Elisabeth Tweesteden Hosp, Dept Neurol, Hilvarenbeekseweg 60, NL-5022 GC Tilburg, Netherlands
关键词
Neurofibromatosis type 1; Ultrasound; Screening; Malignant peripheral nerve sheath tumor; Peripheral nerves; SHEATH TUMORS; PATHOLOGY; MRI; NF1;
D O I
10.1016/j.clinph.2017.11.014
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: To investigate development of sonographic abnormalities and applications of high-resolution ultrasonography (HRUS) in neurofibromatosis type 1 (NF1). Methods: Sixteen asymptomatic or minimally symptomatic NF1 patients underwent HRUS at inclusion and 1 year follow-up. Upper and lower extremity nerves were investigated. Peripheral nerve involvement was graded. Results: Plexiform neurofibromas (PNFs) were found in 7 patients (43.8%) at inclusion and 10 (62.5%) at follow-up. All initially identified PNFs were also found at follow-up; additional PNFs were found by extended longitudinal assessment at follow-up. All 3 patients with minor and 7 patients with severe peripheral nerve involvement had similar involvement at follow-up. Mean nerve size change was -0.2 mm(2) (+/- 1.6) and 0.3 mm(2) (+/- 6.2) in patients with minor and severe involvement. Mean PNF size change was -0.1 mm(2) (+/- 99). Conclusions: HRUS allows qualitative assessment of peripheral nerves, which makes it advantageous as initial imaging technique in suspected neuropathy. Patients with minimal nerve involvement remained so, and might therefore require less follow-up for malignant peripheral nerve sheath tumor (MPNSTs) development. Measured change in PNF size was highly variable. Repeating an extensive standardized HRUS protocol during follow-up thus seems less useful to screen for MPNSTs. (C) 2017 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:354 / 359
页数:6
相关论文
共 50 条
  • [21] Nerve ultrasound as follow-up tool in treated multifocal motor neuropathy
    Rattay, T. W.
    Winter, N.
    Decard, B. F.
    Dammeier, N. M.
    Haertig, F.
    Ceanga, M.
    Axer, H.
    Grimm, A.
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 2017, 24 (09) : 1125 - 1134
  • [22] Ultrasound assessment of peripheral nerve pathology in neurofibromatosis type 1 and 2
    Winter, Natalie
    Rattay, Tim W.
    Axer, Hubertus
    Schaeffer, Eva
    Decard, Bernhard F.
    Gugel, Isabel
    Schuhmann, Martin
    Grimm, Alexander
    [J]. CLINICAL NEUROPHYSIOLOGY, 2017, 128 (05) : 702 - 706
  • [23] Neurofibromatosis type 1 in children: MR imaging and follow-up studies of central nervous system findings
    Menor, F
    Marti-Bonmati, L
    Arana, E
    Poyatos, C
    Cortina, H
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1998, 26 (02) : 121 - 131
  • [24] Central giant-cell granuloma in a patient with neurofibromatosis type 1: 7 years of follow-up
    Garrido, Michelle Briner
    Jagtap, Rohan
    Matesi, Christopher D.
    Diaz, Vivian
    Hardeman, John
    Gohel, Anita
    [J]. JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2024, 50 (01) : 49 - 55
  • [25] Endocrine Long-Term Follow-Up of Children with Neurofibromatosis Type 1 and Optic Pathway Glioma
    Sani, Ilaria
    Albanese, Assunta
    [J]. HORMONE RESEARCH IN PAEDIATRICS, 2017, 87 (03): : 179 - 188
  • [26] ULTRASOUND IN THE POSTOPERATIVE FOLLOW-UP
    DESLEGTE, R
    [J]. NEUROPEDIATRICS, 1984, 15 (04) : 230 - 230
  • [27] LONG THORACIC NERVE PALSY - FOLLOW-UP STUDY
    GOODMAN, CE
    KENRICK, MM
    BLUM, MV
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1975, 56 (08): : 352 - 355
  • [28] LONG THORACIC NERVE PALSY - FOLLOW-UP STUDY
    GOODMAN, CE
    KENRICK, MM
    BLUM, MV
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1973, 54 (12): : 580 - 580
  • [29] Application of ultrasound in avoiding radial nerve injury during elbow arthroscopy: a retrospective follow-up study
    Xingtao Ge
    Xinghua Ge
    Chen Wang
    Qinghua Liu
    Bin Wang
    Longgang Chen
    Kai Cheng
    Ming Qin
    [J]. BMC Musculoskeletal Disorders, 23
  • [30] Application of ultrasound in avoiding radial nerve injury during elbow arthroscopy: a retrospective follow-up study
    Ge, Xingtao
    Ge, Xinghua
    Wang, Chen
    Liu, Qinghua
    Wang, Bin
    Chen, Longgang
    Cheng, Kai
    Qin, Ming
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)