INTEGRATED LIGHTING AND SHADING CONTROL USING DAYLIGHT MODELLING OF AN OFFICE ROOM

被引:0
|
作者
Lehtovaara, Jorma [1 ]
Pakanen, Jouko [1 ]
机构
[1] Helsinki Univ Technol, Dept Elect, FIN-02150 Espoo, Finland
来源
LIGHT & ENGINEERING | 2009年 / 17卷 / 01期
基金
芬兰科学院;
关键词
artificial lighting; glare; solar altitude; lighting control interface;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An integrated control of both artificial lighting and Venetian blinds is one method of decreasing energy consumption in office buildings. However, developing a practical and viable control system is not straightforward. Choosing the right illuminance level for the whole room and, at the same time, preventing the occupants from glare and direct sun is a demanding task. Besides technical problems, the Northern climate also sets limits to daylight control. Low solar altitudes and dynamic daylight situations are difficult to combine with the control algorithm. The paper presents one approach in which daylight measurements and computer simulations were utilized in modelling and control of the lighting system. The approach was demonstrated by combining the model with the DALI (Digital Addressable Lighting Interface) lighting control installed in a test room.
引用
收藏
页码:90 / 97
页数:8
相关论文
共 50 条
  • [11] Estimation of energy saving by daylight integrated artificial lighting system using Indian daylight data
    Pal, S.
    Roy, B.
    Neogi, S.
    Journal of the Institution of Engineers (India): Electrical Engineering Division, 2008, 89 (SEP): : 16 - 21
  • [12] Modeling user control of lighting and shading devices in office buildings:: An empirical case study
    Mohammadi, Abdolazim
    Kabir, Elham
    Mahdavi, Ardeshir
    Proeglhoef, Claus
    BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 772 - 778
  • [13] Occupants' operation of lighting and shading systems in office buildings
    Department of Building Physics and Building Ecology, Vienna University of Technology, Vienna, Austria
    Journal of Building Performance Simulation, 2008, 1 (01) : 57 - 65
  • [14] An automated control of daylight blinds and artificial lighting integrated scheme for therapeutic use
    Chen, Yaodong
    Guo, Yudong
    Liu, Qiuping
    Liu, Yang
    Lei, Yuanfang
    JOURNAL OF BUILDING ENGINEERING, 2023, 73
  • [15] A Simplified Open-loop Control Strategy for Integrated Shading and Lighting Systems Using Machine Learning
    Xie, Jiarong
    Sawyer, Azadeh Omidfar
    PROCEEDINGS OF BUILDING SIMULATION 2021: 17TH CONFERENCE OF IBPSA, 2022, 17 : 3172 - 3179
  • [16] Solar shading control strategies in cold climates - Heating, cooling demand and daylight availability in office spaces
    Grynning, Steinar
    Time, Bent
    Matusiak, Barbara
    SOLAR ENERGY, 2014, 107 : 182 - 194
  • [17] FAST energy and daylight optimization of an office with fixed and movable shading devices
    Manzan, Marco
    Clarich, Alberto
    BUILDING AND ENVIRONMENT, 2017, 113 : 175 - 184
  • [18] Energy and Demand Saving Potential due to Integrated HVAC, Lighting, and Shading Controls in Small Office Building
    Vanage, Soham
    Dong, Hao
    Cetin, Kristen
    CONSTRUCTION RESEARCH CONGRESS 2022: COMPUTER APPLICATIONS, AUTOMATION, AND DATA ANALYTICS, 2022, : 443 - 452
  • [19] Smart lighting system using ANN-IMC for personalized lighting control and daylight harvesting
    Nandha Kumar Kandasamy
    Giridharan Karunagaran
    Costas Spanos
    侯恩哲
    建筑节能, 2018, 46 (07) : 41 - 41
  • [20] A camera as a sensor for lighting and shading control
    Newsham, Guy R.
    Arsenault, C.
    Lighting Research and Technology, 2009, 41 (02): : 143 - 160