Portable device for on-site detection of ammonia nitrogen

被引:9
|
作者
Xu, Xianbao [1 ,2 ,3 ,4 ,6 ]
Bai, Zhuangzhuang [1 ,5 ]
Wang, Tan [1 ,2 ,3 ,4 ]
机构
[1] China Agr Univ, Natl Innovat Ctr Digital Fishery, Beijing 100083, Peoples R China
[2] Minist Agr & Rural Affairs, Key Lab Smart Farming Aquat Anim & Livestock, Beijing 100083, Peoples R China
[3] China Agr Univ, Beijing Engn & Technol Res Ctr Internet Things Agr, Beijing 100083, Peoples R China
[4] China Agr Univ, Coll Informat & Elect Engn, Beijing 100083, Peoples R China
[5] Shandong Agr Univ, Coll Mech & Elect Engn, Tai An 271018, Peoples R China
[6] China Agr Univ, POB 121,17 Tsinghua East Rd, Beijing 100083, Peoples R China
来源
关键词
Ammonia nitrogen measurement; Colorimetric detection; Portable device; Test paper; Aquaculture; ION-SELECTIVE ELECTRODE; SPECTROPHOTOMETRIC DETERMINATION; WATER; SALICYLATE; PH;
D O I
10.1016/j.inpa.2022.07.003
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
Portable measurement of ammonia nitrogen in water is of great significance for water quality monitoring. It's beneficial to reduce biological diseases and promote aquatic product safety. Traditional methods such as Nessler's reagent method suffer from complex operation, time delays and toxic residues. To realize simple and pollution-free detection, this paper develops a low-cost portable device for ammonia nitrogen detection. A test paper was proposed to cooperate the device and offer a chromogenic reaction. The portable device reduces the impact of any ambient light, simplifies the operation, and provides human-computer interaction. The result obtained for the detection range of 0.4-10 mg/L (R2 are 0.990 2 and 0.989 3 for the rang of 0.4-4.5 and 4.5-10 mg/L, respectively) with the detection limit of 0.36 mg/L, and the average recovery of aquaculture water is 100.98- 137.75%. The results show that the portable device can provide a great potential for onsite detection ammonia nitrogen concentration.(c) 2022 China Agricultural University. Production and hosting by Elsevier B.V. on behalf of KeAi. This is an open access article under the CC BY-NC-ND license (http://creativecommons. org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:475 / 484
页数:10
相关论文
共 50 条
  • [41] ON-SITE POWER GENERATION FOR AMMONIA PRODUCTION
    SAULT, RA
    [J]. CHEMICAL ENGINEERING PROGRESS, 1968, 64 (03) : 57 - &
  • [42] Portable Multi-Channel Electrochemical Device with Good Interaction and Wireless Connection for On-Site Testing
    Xu, Yifei
    Ning, Haohao
    Yu, Shixin
    Liu, Shikun
    Zhang, Yan
    Niu, Chunyan
    Zhang, Yongzhuo
    Low, Sze Shin
    Liu, Jingjing
    [J]. MICROMACHINES, 2023, 14 (01)
  • [43] ON-SITE PRODUCTION OF GASEOUS NITROGEN
    不详
    [J]. MANUFACTURING CHEMIST, 1987, 58 (05): : 69 - 69
  • [44] Evaluation of the triage PPY on-site testing device for the detection of dextropropoxyphene in urine
    Poklis, A
    Poklis, JL
    Tarnai, LD
    Backer, RC
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2004, 28 (06) : 485 - 488
  • [45] EVALUATION OF PORTABLE ANALYZERS FOR ON-SITE CHOLESTEROL SCREENING
    WARNICK, GR
    LUM, C
    [J]. CIRCULATION, 1986, 74 (04) : 383 - 383
  • [46] ON-SITE METALLOGRAPHY MADE POSSIBLE WITH PORTABLE UNIT
    OSGOOD, GR
    [J]. METAL PROGRESS, 1972, 102 (02): : 72 - &
  • [47] Paper-Based Analytical Device for the On-Site Detection of Nerve Agents
    Yamaguchi, Akinori
    Miyaguchi, Hajime
    Ishida, Akihiko
    Tokeshi, Manabu
    [J]. ACS APPLIED BIO MATERIALS, 2021, 4 (08): : 6512 - 6518
  • [48] A novel smartphone-based device for rapid on-site methamphetamine detection
    Liang, Sijia
    Wu, Qiaoyu
    Mao, Jikai
    Gong, Chen
    Yu, Dongdong
    Zhou, Jianguang
    [J]. MATERIALS EXPRESS, 2020, 10 (10) : 1638 - 1645
  • [49] NITROGEN - SWING TO ON-SITE GENERATION
    WOOD, R
    [J]. PROCESS ENGINEERING, 1978, (JUN) : 44 - +
  • [50] Portable Tester AIDS On-Site PIM Analysis
    Browne, Jack
    [J]. MICROWAVES & RF, 2012, 51 (03) : 102 - +