Microorganism inactivation by an ozonation step optimized for micropollutant removal from tertiary effluent

被引:6
|
作者
Schaar, H. [1 ]
Sommer, R. [2 ]
Schuerhagl, R. [2 ]
Yillia, P. [1 ]
Kreuzinger, N. [1 ]
机构
[1] Vienna Univ Technol, Inst Water Qual Resources & Waste Management, A-1040 Vienna, Austria
[2] Med Univ Vienna, Inst Hyg & Appl Immunol, A-1095 Vienna, Austria
关键词
Bacillus subtilis spores; bacterial faecal indicators; bacteriophage MS2; biological oxygen demand ozonation; tertiary effluent; WASTE-WATER TREATMENT; OZONE DISINFECTION; TREATMENT PLANTS; DRINKING-WATER; OXIDATION; QUALITY;
D O I
10.2166/wst.2013.212
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper demonstrates the additional benefit of the microbicidal efficacy of an ozonation plant implemented for micropollutant removal from tertiary effluent. Due to the low amount of viruses and protozoa in the tertiary effluent, bacteriophage MS2 and spores of Bacillus subtilis were dosed as surrogates. At specific ozone consumptions of 0.6 and 0.9 g O-3/g dissolved organic carbon (DOC) a 2-log colony forming unit (CFU) reduction was achieved for indigenous Escherichia coli and enterococci, and the limits of the European bathing water directive for the excellent quality of inland waters were met. Higher removal was impeded by the shielding effect of suspended solids in the effluent, which implies the combination of ozonation with a preceding filtration step if higher microbicidal performances are required. The surrogate virus MS2 was reduced by 4-5 log while no significant inactivation was detected for B. subtilis spores. Additionally, the impact of ozonation on the biochemical oxygen demand (BOD) was studied. The BOD5 measurement was not adversely affected despite the reduced concentration of microorganisms after ozonation. The intrinsic increase in BOD5 averaged 15% at 0.6-0.7 g O-3/g DOC. The impact of the projected increase on the surface water quality is generally not considered a problem but has to be assessed on a case-by-case approach.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [31] Sequential ozonation and Fenton process for the removal of refractory organics from semi-aerobic aged refuse biofilter leachate effluent
    Pan, Xuqin
    DESALINATION AND WATER TREATMENT, 2020, 207 : 172 - 179
  • [32] Advanced technique of catalytic ozonation-enhanced coagulation for the efficient removal of low coagulability refractory organics from secondary effluent
    Qiu, Jin-Li
    Li, Da-Wei
    Jing, Shi-Chao
    Qiu, Huan
    Liu, Fu-Qiang
    CHEMOSPHERE, 2022, 303
  • [33] Removal of refractory organics from piggery bio-treatment effluent by the catalytic ozonation process with piggery biogas residue biochar as the catalyst
    Luo, Zifeng
    Wang, Dehan
    Zeng, Weishen
    Yang, Jie
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 734
  • [34] Thermochemical precipitation as a pretreatment step for the chemical oxygen demand and color removal from pulp and paper mill effluent
    Garg, A
    Mishra, IM
    Chand, S
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2005, 44 (07) : 2016 - 2026
  • [35] Evaluation of a recirculating hydroponic bed bioreactor for removal of contaminants of emerging concern from tertiary-treated wastewater effluent
    Recsetar, Matthew S.
    Fitzsimmons, Kevin M.
    Cuello, Joel L.
    Hoppe-Jones, Christiane
    Snyder, Shane A.
    CHEMOSPHERE, 2021, 262
  • [36] Removal of organic contaminants from secondary effluent by anodic oxidation with a boron-doped diamond anode as tertiary treatment
    Garcia-Segura, Sergi
    Keller, Juerg
    Brillas, Enric
    Radjenovic, Jelena
    JOURNAL OF HAZARDOUS MATERIALS, 2015, 283 : 551 - 557
  • [37] Porous Organic Polymers with Embedded Fe2O3 Nanoparticles for Pathogenic Microorganism Inactivation and Iodine Removal from Nuclear Water
    Guo, Taoyan
    Wang, Ying
    Li, Juan
    Ding, Xiaoyan
    Sun, Qi
    Yuan, Jingsong
    Ma, Lianru
    Hao, Huihui
    Zhou, Baolong
    ACS APPLIED NANO MATERIALS, 2024, 7 (15) : 17391 - 17405
  • [38] Effect of ozonation as pre-treatment and polishing step on removal of ecotoxicity and alkylphenol ethoxylates from tank truck cleaning wastewater
    Poelmans, Sven
    Nagels, Maarten
    Mignot, Melanie
    Dewil, Raf
    Cabooter, Deirdre
    Dries, Jan
    JOURNAL OF WATER PROCESS ENGINEERING, 2020, 37
  • [39] Removal of soluble organic containments from dyeing biochemical effluent by SO32-/HSO5- system optimized
    Zhang, Hao-Nan
    Tang, Hai
    Li, Qiang
    Zhang, Chen
    Liu, Gui-Zhong
    Zhongguo Huanjing Kexue/China Environmental Science, 2019, 39 (07): : 2854 - 2863
  • [40] Successful application of photocatalytic recycled TiO2-GO membranes for the removal of trace organic compounds from tertiary effluent
    de Oliveira C.P.M.
    Sperle P.
    Arcanjo G.S.
    Koch K.
    Viana M.M.
    Drewes J.E.
    Amaral M.C.S.
    Chemosphere, 2024, 362