Characteristics of wavelength-shifting fibers for the electromagnetic calorimeter of the PHENIX system

被引:0
|
作者
Belikov, SV
White, S
Gutnikov, YE
Denisov, AG
Dyachkov, AI
Zharkov, VV
Kistenev, EP
Kochetkov, VI
Makeev, AV
Makeev, VV
Melnikov, EA
Usachev, AP
机构
[1] BROOKHAVEN NATL LAB,UPTON,NY 11973
[2] AO POLIMERSINTEZ,VLADIMIR,RUSSIA
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
We studied the characteristics of some domestically-produced wavelength-shifting fibers, featuring various re-emitting additives and various core materials (polystyrene and polymethyl metacrylate). Characteristics of BCF-92, BCF-99(29A), and BCF-99(29B) by Bicron were also measured. Absorption and scintillation spectra of the fibers are shown. Values of the Light yield, the attenuation length and the scintillation decay time of the fibers are presented.
引用
收藏
页码:665 / 673
页数:9
相关论文
共 50 条
  • [21] Performance of New Kuraray Wavelength-shifting Fibers with Short Decay Time
    Kodama, Shoma
    Kobayashi, Hokuto
    Okinaga, Wataru
    Nakagiri, Kota
    Nakajima, Yasuhiro
    Yokoyama, Masashi
    PROGRESS OF THEORETICAL AND EXPERIMENTAL PHYSICS, 2024, 2024 (05):
  • [22] Development of a fast neutron radiography converter using wavelength-shifting fibers
    Matsubayashi, M
    Hibiki, T
    Mishima, K
    Yoshii, K
    Okamoto, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 510 (03): : 325 - 333
  • [23] Characteristics of molded polystyrene scintillator for electromagnetic calorimeter of the PHENIX apparatus
    Belikov, SV
    White, S
    Gutnikov, YE
    Denisov, AG
    Dyachkov, AI
    Zharkov, VV
    Kistenev, EP
    Kochetkov, VI
    Makeev, AV
    Mayatskii, VA
    Melnikov, EA
    Usachev, AP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1996, 39 (04) : 498 - 505
  • [24] Influence of OPD in Wavelength-shifting Interferometry
    Wang Hongjun
    Tian Ailing
    Liu Bingcai
    Dang Juanjuan
    FOURTH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2010, 7522
  • [25] LEAD SCINTILLATOR ELECTROMAGNETIC CALORIMETER WITH WAVELENGTH SHIFTING FIBER READOUT
    ATOYAN, GS
    GLADYSHEV, VA
    GNINENKO, SN
    ISAKOV, VV
    KOVZELEV, AV
    MONICH, EA
    POBLAGUEV, AA
    PROSKURYAKOV, AL
    SEMENYUK, IN
    LAPSHIN, VG
    PROTOPOPOV, YV
    RYKALIN, VI
    SEMENOV, VK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2): : 144 - 154
  • [26] The Nonuniformity of the Light Yield in Scintillator Strips with Wavelength-Shifting Fibers of the DANSS Detector
    Alekseev, I. G.
    Kalinkin, D. V.
    Machikhiliyan, I. V.
    Nesterov, V. M.
    Pogorelov, N. A.
    Rusinov, V. Yu.
    Svirida, D. N.
    Starostin, A. S.
    Tarkovsky, E. I.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2018, 61 (03) : 328 - 331
  • [27] Trigger circuits for the PHENIX electromagnetic calorimeter
    Frank, SS
    Britton, CL
    Wintenberg, AL
    Young, GR
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 680 - 684
  • [28] The Nonuniformity of the Light Yield in Scintillator Strips with Wavelength-Shifting Fibers of the DANSS Detector
    I. G. Alekseev
    D. V. Kalinkin
    I. V. Machikhiliyan
    V. M. Nesterov
    N. A. Pogorelov
    V. Yu. Rusinov
    D. N. Svirida
    A. S. Starostin
    E. I. Tarkovsky
    Instruments and Experimental Techniques, 2018, 61 : 328 - 331
  • [29] Development of a converter made of scintillator and wavelength-shifting fibers for fast neutron radiography
    Zou, Yubin
    Guo, Li'an
    Guo, Zhiyu
    Tang, Guoyou
    Zhang, Guohui
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 605 (1-2): : 73 - 76
  • [30] Physics analysis with the PHENIX electromagnetic calorimeter
    Tarján, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 682 - 686