Perspective Deconvolution of the dehydration degradation mechanism in polymer electrolyte membrane fuel cells using electrochemical impedance analysis combined with the transmission line model under low humidity

被引:16
|
作者
Kwon, JunHwa [1 ]
Jo, Seunghyun [1 ]
Cho, Ki-Yeop [1 ]
Eom, KwangSup [1 ]
机构
[1] Gwangju Inst Sci & Technol GIST, Sch Mat Sci & Engn SMSE, 123 Cheomdangwagi Ro, Gwangju, South Korea
关键词
Polymer electrolyte membrane fuel cell; Electrochemical impedance spectroscopy; Cell degradation; Transmission line model; Dehydration degradation mechanism; Sequential degradation mechanism; CATHODE CATALYST LAYER; COMPLEX CAPACITANCE ANALYSIS; IONIC-CONDUCTIVITY; PEMFC; RESISTANCE; SPECTROSCOPY; STACK; THICKNESSES; DURABILITY; MANAGEMENT;
D O I
10.1016/j.jpowsour.2020.228587
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Herein, electrochemical impedance spectroscopy (EIS) analysis is performed under low-relative humidity conditions (RH30) to use the transmission line model (TLM) to emphasize ionic resistance in a polymer electrolyte membrane fuel cell (PEMFC). In particular, EIS measurement under RH30 based on the TLM (TLM-RH30) facilitates a focus on the inherent properties of the membrane electrode assembly (MEA) by deliberately limiting and separating the proton conductivity from the complicated impedance circuits. To verify the feasibility of TLMRH30 in EIS analysis, the dehydration degradation test of a PEMFC is performed under RH 30% for more than 600 h. From the electrochemical results obtained using TLM-RH30, the degradation mechanism can be sequentially deconvoluted with respect to operating time; (i) first, an increase in ionic resistance occurs, followed by (ii) membrane thinning and (iii) reverse current decay inducing severe cathode deterioration due to carbon corrosion. The sequential degradation mechanism under dehydration is also supported by the surface analysis results of deteriorated MEAs using SEM TEM, EDS, XRD, and XPS. It is notable that EIS analysis adopting TLMRH30 enable an accurate diagnosis by establishing the sequential degradation causes in each MEA component, such as the ionomer, membrane, and catalyst layer, in a PEMFC.
引用
收藏
页数:12
相关论文
共 33 条
  • [31] Effect of carbon dioxide on the contamination of low temperature and high temperature PEM (polymer electrolyte membrane) fuel cells. Influence of temperature, relative humidity and analysis of regeneration processes
    Antonio Diaz, Manuel
    Iranzo, Alfredo
    Rosa, Felipe
    Isorna, Fernando
    Lopez, Eduardo
    Pedro Bolivar, Juan
    [J]. ENERGY, 2015, 90 : 299 - 309
  • [32] Enhanced electrochemical performance and long-term durability of composite membranes through a binary interface with sulfonated unzipped graphite nanofibers for polymer electrolyte fuel cells operating under low relative humidity
    Kim, Ae Rhan
    Vinothkannan, Mohanraj
    Ramakrishnan, Shanmugam
    Park, Byung-Hyun
    Han, Myung-Kwan
    Yoo, Dong Jin
    [J]. APPLIED SURFACE SCIENCE, 2022, 593
  • [33] Analysis of performance stability under conditions of high & low humidity of polymer electrolyte fuel cells with interdigitated gas flow channels formed on a gas diffusion layer: An X-ray imaging and modeling study
    Inoue, Tatsuya
    Sakai, Daiki
    Hirayama, Naoki
    Nasu, Mitsunori
    Suzuki, Takahiro
    Tsushima, Shohji
    Inukai, Junji
    Tryk, Donald A.
    Watanabe, Masahiro
    Iiyama, Akihiro
    Uchida, Makoto
    [J]. JOURNAL OF POWER SOURCES, 2023, 585