共 41 条
Determination of Total Sulphur and Chloride in Solid Biomass Fuel by Tube Furnace Combustion-Ion Chromatography
被引:1
|作者:
Wang, Shuo
[1
,2
,3
]
Duan, Weiyu
[1
,2
,3
]
Cao, Cong
[1
,2
,3
]
Yang, Zheyuan
[1
,2
,3
]
Lv, Huanming
[1
,2
,3
]
Qiu, Zhaojun
[1
,2
,3
]
机构:
[1] LiaoNing Inspect Inst Prod Qual Supervis, Shenyang 110144, Peoples R China
[2] Natl Ctr Petr Qual Supervis Inspect Shen Yang, Shenyang 110144, Peoples R China
[3] Liaoning Prov Ind Lubricating Oil Monitoring Engn, Shenyang 110144, Peoples R China
来源:
关键词:
D O I:
10.1088/1755-1315/440/4/042104
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
A tube furnace combustion-ion chromatography method for the determination of total sulfur and chlorine in biomass solid fuel were established. Taking 0.15% hydrogen peroxide as absorption liquid, the sulfide of the sample is converted into sulfate ion after combustion. The total sulfur and chlorine content in the biomass solid fuel is determined by ion chromatography. Under the optimized chromatographic conditions, the detection limit of sulfate ion chromatography is 3.1 mg / kg and the detection limit of chlorine is 4.6 mg/kg with the linear relationship in the range of 0.05-10.00 mg/L. The relative standard deviation of precision and repeatability is less than 5%, the average recovery of total sulfur and chlorine were 97.9% and 96.6%. This method is simple, rapid and reproducible. It can be used for the determination of total sulfur and chlorine in biomass solid fuel.
引用
收藏
页数:4
相关论文