Changes in the anterior chamber configuration after small-incision cataract surgery with posterior chamber intraocular lens implantation

被引:89
|
作者
Kurimoto, Y [1 ]
Park, M [1 ]
Sakaue, H [1 ]
Kondo, T [1 ]
机构
[1] KOBE CITY GEN HOSP,DEPT OPHTHALMOL,KOBE,HYOGO,JAPAN
关键词
D O I
10.1016/S0002-9394(14)71694-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To report quantitative changes in the anterior chamber configuration after small-incision cataract surgery with implantation of a posterior chamber intraocular lens by means of ultrasound biomicroscopy. METHODS: We examined the anterior chamber configuration of 20 eyes of 20 patients before and 3 months after small-incision cataract surgery (phacoemulsification and aspiration plus foldable intraocular lens implantation through a 3.0- to 4.0-mm self-sealing wound) by means of ultrasound biomicroscopy, The following variables were measured: the anterior chamber depth at the center of the cornea, the angle-opening distance 250 mu m from the scleral spur (AOD250), the angle-opening distance 500 mu m from the scleral spur (AOD500), and the trabecular-iris angle. RESULTS: The anterior chamber depth at the center of the cornea, AOD250, AOD500, and trabecular-iris angle increased significantly after surgery, The preoperative anterior chamber depth at the center of the cornea and trabecular iris angle were negatively correlated with the differences between the postoperative and preoperative values (P <.01). The preoperative values of all variables examined were negatively correlated with the ratios of the postoperative value to the preoperative value (P <.002). CONCLUSIONS: The present results showed that small-incision cataract surgery significantly deepened the anterior chamber and widened its angle, The more shallow the preoperative anterior cham her was, the greater the postoperative change of the chamber was; and the more narrow the preoperative angle was, the greater the postoperative change of the angle was.
引用
收藏
页码:775 / 780
页数:6
相关论文
共 50 条
  • [21] ANTERIOR-CHAMBER ASPIRATE CULTURES IN SMALL-INCISION CATARACT-SURGERY
    MANNERS, TD
    CHITKARA, DK
    MARSH, PJ
    STODDART, MG
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (10) : 878 - 880
  • [22] Anterior chamber contamination during phacoemulsification and manual small-incision cataract surgery
    Parmar, Pragya
    Salman, Amjad
    Kaliamurthy, Jayaraman
    Prasanth, Duraisamy Aravind
    Thomas, Philip Aloysius
    Jesudasan, Christdas Arul Nelson
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (06) : 1160 - 1161
  • [23] Posterior chamber intraocular lens in the anterior chamber
    Zinkernagel, M.
    Ammann-Rauch, D.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2007, 224 (04) : 309 - 310
  • [24] Changes in anterior chamber figure after small-incision cataract surgery: A quantitative study using ultrasound biomicroscopy.
    Kurimoto, Y
    Park, M
    Sakaue, H
    Kondo, T
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 3755 - 3755
  • [25] Influence of anterior chamber depth and vault on anterior chamber angle morphology after phakic posterior chamber intraocular lens implantation
    Sanchez-Trancon, Angel
    Manito, Santiago Cerpa
    Sierra, Oscar Torrado
    Baptista, Antonio Manuel
    Serra, Pedro Miguel
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [26] Influence of anterior chamber depth and vault on anterior chamber angle morphology after phakic posterior chamber intraocular lens implantation
    Angel Sánchez-Trancón
    Santiago Cerpa Manito
    Oscar Torrado Sierra
    António Manuel Baptista
    Pedro Miguel Serra
    [J]. International Ophthalmology, 44
  • [27] Changes in anterior chamber depth and intraocular pressure after uneventful phacoemulsification and posterior chamber intraocular lens implantation. A role in glaucoma?
    Issa, SA
    Pacheco, J
    Beatty, S
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U165 - U165
  • [28] Visual outcome of conventional extra-capsular cataract extraction with posterior chamber intraocular lens implantation versus manual small incision cataract surgery
    Sharma, A.
    Lavaju, P.
    [J]. NEPALESE JOURNAL OF OPHTHALMOLOGY, 2009, 1 (02) : 151 - 151
  • [29] Safety of posterior chamber phakic intraocular lenses for the correction of high myopia -: Anterior segment changes after posterior chamber phakic intraocular lens implantation
    Jiménez-Alfaro, I
    del Castillo, JMB
    García-Feijoó, J
    de Bernabé, JGG
    de la Iglesia, JMS
    [J]. OPHTHALMOLOGY, 2001, 108 (01) : 90 - 99
  • [30] INTRAOCULAR-PRESSURE AND ANTERIOR-CHAMBER DEPTH BEFORE AND AFTER EXTRACAPSULAR CATARACT-EXTRACTION WITH POSTERIOR CHAMBER LENS IMPLANTATION
    STEUHL, KP
    MARAHRENS, P
    FROHN, C
    FROHN, A
    [J]. OPHTHALMIC SURGERY AND LASERS, 1992, 23 (04): : 233 - 237