Descemet's Stripping Automated Endothelial Keratoplasty Three-Year Graft and Endothelial Cell Survival Compared with Penetrating Keratoplasty

被引:121
|
作者
Price, Marianne O. [1 ]
Gorovoy, Mark [2 ]
Price, Francis W., Jr. [3 ]
Benetz, Beth A. [4 ,5 ]
Menegay, Harry J. [4 ,5 ]
Lass, Jonathan H. [4 ,5 ,6 ]
机构
[1] Cornea Res Fdn Amer, Indianapolis, IN 46260 USA
[2] Gorovoy Eye Specialists, Ft Myers, FL USA
[3] Price Vis Grp, Indianapolis, IN USA
[4] Case Western Reserve Univ, Sch Med, Dept Ophthalmol & Visual Sci, Cleveland, OH USA
[5] Univ Hosp, Inst Eye, Cleveland, OH USA
[6] Case Western Reserve Univ, Sch Med, Dept Epidemiol & Biostat, Cleveland, OH 44106 USA
关键词
SPECULAR MICROSCOPY ANCILLARY; CORNEA DONOR; CELL LOSS; INSERTION TECHNIQUES; TRANSPLANTATION; SURVIVAL; DENSITY; AGE;
D O I
10.1016/j.ophtha.2012.08.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess 3-year outcomes of Descemet's stripping automated endothelial keratoplasty (DSAEK) in comparison with penetrating keratoplasty (PKP) from the Cornea Donor Study (CDS). Design: Prospective, multicenter, nonrandomized clinical trial. Participants: A total of 173 subjects undergoing DSAEK for a moderate risk condition (principally Fuchs' dystrophy or pseudophakic corneal edema) compared with 1101 subjects undergoing PKP from the CDS. Methods: The DSAEK procedures were performed by 2 experienced surgeons using the same donor and similar recipient criteria as for the CDS PKP procedures, performed by 68 surgeons. Graft success was assessed by Kaplan-Meier survival analysis. Central endothelial cell density (ECD) was determined from baseline donor and postoperative central endothelial images by the reading center used in the CDS Specular Microscopy Ancillary Study. Main Outcome Measures: Graft clarity and ECD. Results: The donor and recipient demographics were comparable in the DSAEK and PKP groups, except that the proportion of Fuchs' dystrophy cases was higher in the DSAEK cohort. The 3-year survival rate did not differ significantly between DSAEK and PKP procedures performed for either Fuchs' dystrophy (96% for both; P = 0.81) or non-Fuchs' cases (86% vs. 84%, respectively; P = 0.41). Principal causes of graft failure or regraft within 3 years after DSAEK and PKP were immunologic graft rejection (0.6% vs. 3.1%), endothelial decompensation in the absence of documented rejection (1.7% vs 2.1%), unsatisfactory visual or refractive outcome (1.7% vs. 0.5%), and infection (0% vs. 1.1%), respectively. The 3-year predicted probability of a rejection episode was 9% with DSAEK versus 20% with PKP (P = 0.0005). The median 3-year cell loss for DSAEK and PKP was 46% and 51%, respectively (P = 0.33), in Fuchs' dystrophy cases and 59% and 61%, respectively (P = 0.70), in the non-Fuchs' cases. At 3 years, use of a smaller DSAEK insertion incision was associated with significantly higher cell loss (60% vs. 33% for 3.2-and 5.0-mm incisions, respectively; P = 0.0007), but not with a significant difference in graft survival (P = 0.45). Conclusions: The graft success rate and endothelial cell loss were comparable at 3 years for DSAEK and PKP procedures. A 5-mm DSAEK incision width was associated with significantly less cell loss than a 3.2-mm incision. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2013;120:246-251 (C) 2013 by the American Academy of Ophthalmology.
引用
收藏
页码:246 / 251
页数:6
相关论文
共 50 条
  • [41] Comparison of outcomes of penetrating keratoplasty versus Descemet’s stripping automated endothelial keratoplasty for penetrating keratoplasty graft failure due to corneal edema
    Anna S. Kitzmann
    George R. Wandling
    John E. Sutphin
    Kenneth M. Goins
    Michael D. Wagoner
    International Ophthalmology, 2012, 32 : 15 - 23
  • [42] Outcomes of Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty and penetrating keratoplasty from a single centre study
    Heinzelmann, S.
    Boehringer, D.
    Eberwein, P.
    Reinhard, T.
    Maier, P.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (03) : 515 - 522
  • [43] Comparison of the Visual Outcomes of Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) and Penetrating Keratoplasty
    Chikama, T. -I.
    Sato, Y.
    Morita, Y.
    Yanai, R.
    Yamada, N.
    Morishige, N.
    Nishida, T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [44] Endothelial Keratoplasty: Fellow Eyes Comparison of Descemet Stripping Automated Endothelial Keratoplasty and Descemet Membrane Endothelial Keratoplasty
    Guerra, Frederico P.
    Anshu, Arundhati
    Price, Marianne O.
    Price, Francis W.
    CORNEA, 2011, 30 (12) : 1382 - 1386
  • [45] Descemet stripping automated endothelial keratoplasty
    Sharma, Namrata
    Maharana, Prafulla K.
    Singhi, Shipra
    Aron, Neelima
    Patil, Mukesh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (03) : 198 - 209
  • [46] Descemet membrane endothelial keratoplasty compared with ultrathin Descemet stripping automated endothelial keratoplasty: a meta-analysis
    Sela, Tal Corina
    Iflah, Moti
    Muhsen, Khitam
    Zahavi, Alon
    BMJ OPEN OPHTHALMOLOGY, 2023, 8 (01):
  • [47] Five-year Clinical Results Comparing Descemet Stripping Automated Endothelial Keratoplasty and non Descemet Stripping Automated Endothelial Keratoplasty
    Omoto, Takashi
    Toyono, Tetsuya
    Shirakawa, Rika
    Yoshida, Junko
    Miyai, Takashi
    Yamagami, Satoru
    Usui, Tomohiko
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [48] Comparison of graft survival following penetrating keratoplasty and Descemet’s stripping endothelial keratoplasty in eyes with a glaucoma drainage device
    Shawn M. Iverson
    Oriel Spierer
    George C. Papachristou
    William J. Feuer
    Wei Shi
    David S. Greenfield
    Terrence P. O’Brien
    International Ophthalmology, 2018, 38 : 223 - 231
  • [49] Comparison of graft survival following penetrating keratoplasty and Descemet's stripping endothelial keratoplasty in eyes with a glaucoma drainage device
    Iverson, Shawn M.
    Spierer, Oriel
    Papachristou, George C.
    Feuer, William J.
    Shi, Wei
    Greenfield, David S.
    O'Brien, Terrence P.
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (01) : 223 - 231
  • [50] DESCEMET STRIPPING ENDOTHELIAL KERATOPLASTY IN EYES WITH ENDOTHELIAL DECOMPENSATION AFTER PENETRATING KERATOPLASTY
    Beltz, Jacqueline
    Busin, Massimo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 : 34 - 34