Intensity-based registration of freehand 3D ultrasound and CT-scan images of the kidney

被引:5
|
作者
Leroy, Antoine [1 ]
Mozer, Pierre [1 ]
Payan, Yohan [1 ]
Troccaz, Jocelyne [1 ]
机构
[1] Fac Med, TIMC Lab IN3S, F-38706 La Tronche, France
关键词
Computer-assisted surgery; Kidney; Intensity-based registration; CT-scanner; Freehand ultrasound;
D O I
10.1007/s11548-007-0077-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objectives This paper presents a method to register a preoperative computed-tomography (CT) volume to a sparse set of intra-operative ultra-sound (US) slices. In the context of percutaneous renal puncture, the aim is to transfer planning information to an intra-operative coordinate system. Materials and methods The spatial position of the US slices is measured by optically localizing a calibrated probe. Assuming the reproducibility of kidney motion during breathing, and no deformation of the organ, the method consists in optimizing a rigid 6 degree of freedom transform by evaluating at each step the similarity between the set of US images and the CT volume. The correlation between CT and US images being naturally rather poor, the images were preprocessed in order to increase their similarity. Among the similarity measures formerly studied in the context of medical image registration, correlation ratio turned out to be one of the most accurate and appropriate, particularly with the chosen non-derivative minimization scheme, namely Powell-Brent's. The resulting matching transforms are compared to a standard rigid surface registration involving segmentation, regarding both accuracy and repeatability. Results The obtained results are presented and discussed.
引用
下载
收藏
页码:31 / 41
页数:11
相关论文
共 50 条
  • [31] Effective intensity-based 2D/3D rigid registration between fluoroscopic X-ray and CT
    Knaan, D
    Joskowicz, L
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 1, 2003, 2878 : 351 - 358
  • [32] Using mathematical morphology for the anatomical labeling of vertebrae from 3D CT-scan images
    Naegel, Benoit
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (03) : 141 - 156
  • [33] An intensity-based registration algorithm for probabilistic images and its application for 2-D to 3-D image registration
    Rohlfing, T
    Russakoff, DB
    Murphy, MJ
    Maurer, CR
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 581 - 591
  • [34] A parametric intensity-based 3D image registration method for magnetic resonance imaging
    Huajun Song
    Peihua Qiu
    Signal, Image and Video Processing, 2017, 11 : 455 - 462
  • [35] Rigid Registration of Untracked Freehand 2D Ultrasound Sweeps to 3D CT of Liver Tumours
    Cifor, Amalia
    Risser, Laurent
    Heinrich, Mattias P.
    Chung, Daniel
    Schnabel, Julia A.
    ABDOMINAL IMAGING: COMPUTATION AND CLINICAL APPLICATIONS, 2013, 8198 : 155 - 164
  • [36] Geometry-based vs. intensity-based medical image registration: A comparative study on 3D CT data
    Savva, Antonis D.
    Economopoulos, Theodore L.
    Matsopoulos, George K.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 69 : 120 - 133
  • [37] An image registration approach to automated calibration for freehand 3D ultrasound
    Blackall, JM
    Rueckert, D
    Maurer, CR
    Penney, GP
    Hill, DLG
    Hawkes, DJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 462 - 471
  • [38] Elastic registration of 3D ultrasound images
    Foroughi, P
    Abolmaesumi, P
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 1, 2005, 3749 : 83 - 90
  • [39] On intensity-based 3D visual servoing
    Silveira, Geraldo
    ROBOTICS AND AUTONOMOUS SYSTEMS, 2014, 62 (11) : 1636 - 1645
  • [40] Semi-Automatic Algorithm For 3D Volume Reconstruction of Inner Ear Structures Based On CT-Scan Images
    Bouchana, Adil
    Kharroubi, Jamal
    Ridal, Mohammed
    2018 4TH INTERNATIONAL CONFERENCE ON ADVANCED TECHNOLOGIES FOR SIGNAL AND IMAGE PROCESSING (ATSIP), 2018,