Comparison of Contrast Sensitivity and Through Focus in Small-Aperture Inlay, Accommodating Intraocular Lens, or Multifocal Intraocular Lens Subjects

被引:35
|
作者
Vilupuru, Srividhya [1 ]
Lin, Ling [1 ]
Pepose, Jay S. [2 ,3 ]
机构
[1] AcuFocus Inc, Irvine, CA USA
[2] Washington Univ, Sch Med, Pepose Vis Inst, St Louis, MO USA
[3] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63110 USA
关键词
INTRACORNEAL INLAY; SURGICAL-CORRECTION; CLINICAL-EVALUATION; VISUAL PERFORMANCE; PRESBYOPIA; CATARACT; OUTCOMES; DECLINE; ACUITY;
D O I
10.1016/j.ajo.2015.04.023
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare monocular and binocular mesopic contrast sensitivity and through focus following monocular implantation with KAMRA small-aperture inlay (AcuFocus, Irvine, California, USA) vs binocular implantation with an accommodating or multifocal intraocular lens (IOL) implant. DESIGN: Three-treatment randomized clinical trial of presbyopia-correcting IOLs with comparison to results from a previous nonrandomized multicenter clinical trial on the KAMRA corneal inlay. METHODS: Study population of 507 subjects with KAMRA inlays; predetermined subgroups included 327 subjects that underwent contrast sensitivity testing and another 114 subjects for defocus curve testing, along with 78 subjects randomized between bilateral Crystalens Advanced Optics (AO) (Bausch + Lomb Surgical, Aliso Viejo, California, USA), AcrySof IQ ReSTOR +3.0 D (Alcon Laboratories, Fort Worth, Texas, USA), or Tecnis + 4D Multifocal (MF) (Abbott Medical Optics, Santa Ana, California, USA) IOL. RESULTS: KAMRA inlay subjects demonstrated improved intermediate and near vision with minimal to no change to distance vision, better contrast sensitivity in the inlay eye when compared to the multifocals, and better binocular contrast sensitivity when compared to all 3 intraocular lenses. Crystalens AO was superior in uncorrected intermediate vision compared to the KAMRA inlay, but not in distance-corrected intermediate, and was worse in near vision. The multifocals were superior in near vision at their respective optimum near focus points, but worse in intermediate vision compared to both KAMRA inlay and Crystalens AO. CONCLUSIONS: The demonstrated performance of these devices should be considered, along with subjects' visual demands and expectations, degree of crystalline lens dysfunction, and other ocular characteristics, in guiding the selection of small-aperture corneal inlay or specific intraocular lens in the correction of presbyopia. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:150 / 162
页数:13
相关论文
共 50 条
  • [21] Through-focus binocular contrast sensitivity of monofocal and multifocal intraocular lens predicted by an adaptive optics visual simulator
    Alarcon, Aixa
    Canovas, Carmen
    Manzanera, Silvestre
    Prieto, Pedro
    Hileman, Kendra
    Piers, Patricia A.
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [22] Visual Performance of a Small-Aperture Intraocular Lens: First Comparison of Results After Contralateral and Bilateral Implantation
    Ang, Robert Edward
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (01) : 12 - 19
  • [23] Small-aperture corneal inlay in presbyopic patients with prior phakic intraocular lens implantation surgery: 3-month results
    Huseynova, Tukezban
    Kanamori, Tomomi
    Waring, George O.
    Tomita, Minoru
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 1683 - 1686
  • [24] Multifocal intraocular lens providing optimized through-focus performance
    Fernandez, David
    Barbero, Sergio
    Dorronsoro, Carlos
    Marcos, Susana
    OPTICS LETTERS, 2013, 38 (24) : 5303 - 5306
  • [25] The Small-Aperture IC-8 Intraocular Lens: A New Concept for Added Depth of Focus in Cataract Patients
    Grabner, Guenther
    Edward, Robert
    Vilupuru, Srividhya
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (06) : 1176 - 1184
  • [26] Comparison of a New Refractive Multifocal Intraocular Lens with an Inferior Segmental Near Add and a Diffractive Multifocal Intraocular Lens
    Alio, Jorge L.
    Plaza-Puche, Ana B.
    Javaloy, Jaime
    Jose Ayala, Maria
    Moreno, Luis J.
    Pinero, David P.
    OPHTHALMOLOGY, 2012, 119 (03) : 555 - 563
  • [27] Comparison of a new-generation sectorial addition multifocal intraocular lens and a diffractive apodized multifocal intraocular lens
    van der Linden, Jan Willem
    van Velthoven, Mirjam
    van der Meulen, Ivanka
    Nieuwendaal, Carla
    Mourits, Maarten
    Lapid-Gortzak, Ruth
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (01): : 68 - 73
  • [28] Near Visual Performance Results of the Accommodating Intraocular Lens (Tetraflex)® in Comparison to Monofocal Foldable Intraocular Lens
    Rahimi, Firoozeh
    Ghahari, Elham
    Hashemian, Mohammad Naser
    Fallah, Mohammad Reza
    Siatiri, Heidar
    Rajabi, Mohammad Taher
    IRANIAN JOURNAL OF OPHTHALMOLOGY, 2009, 21 (03): : 5 - 10
  • [29] Appearance of images through a multifocal intraocular lens
    Peli, Eli
    Lang, Alan
    Journal of the Optical Society of America A: Optics and Image Science, and Vision, 2001, 18 (02): : 302 - 309
  • [30] Appearance of images through a multifocal intraocular lens
    Peli, E
    Lang, A
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (02): : 302 - 309