Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging

被引:79
|
作者
Le Roux, P [1 ]
Gilles, RJ [1 ]
McKinnon, GC [1 ]
Carlier, PG [1 ]
机构
[1] Gen Elect Med Syst, Buc, France
来源
关键词
cardiac; fast imaging; fast spin-echo; outer volume suppression;
D O I
10.1002/jmri.1880080505
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Among the ultrafast MRI techniques, the single-shot fast spin-echo sequence offers a robust alternative to echo planar imaging, essentially because of a much reduced sensitivity to B-o inhomogeneity. This property is particularly appealing in situations in which B, inhomogeneities can be severe and difficult to correct, such as in cardiac imaging. With single-shot cardiac imaging, however, achieving high resolution over the necessarily large field of views without introducing back-folding artifacts is problematic. One option is to use multishot sequences. However, then issues related to cardiac gating arise. Another solution is to use, optimized presaturation slabs with quadratic phase pulses generated by the Shinnar-LeRoux algorithm. These can be set to reduce the field of view in the phase-encoding direction, resulting in a reduction in the number of phase-encoding steps. For instance, for a 1 x 2-mm spatial resolution, over a rectangular, 250 x 125-mm held of view, and using a half Fourier acquisition, an echo-train length of only 40 is required. With a 4,5-msec echo spacing, the total imaging time is approximate to 180 msec, The efficacy of this solution on phantoms and volunteers is demonstrated. Multislice short-axis examinations of the whole heart, realized within a single short breath-hold of approximate to 10 seconds, are shown. The possibility of investigating not only cardiac anatomy but also both contractility and myocardial perfusion is discussed.
引用
收藏
页码:1022 / 1032
页数:11
相关论文
共 50 条
  • [41] On the application of a non-CPMG single-shot fast spin-echo sequence to diffusion tensor MRI of the human brain
    Bastin, ME
    Le Roux, P
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (01) : 6 - 14
  • [42] MR cisternography using a three-dimensional half-Fourier single-shot fast spin-echo sequence
    Tsuchiya, K
    Yamakami, N
    Hachiya, J
    Kassai, Y
    EUROPEAN RADIOLOGY, 1998, 8 (03) : 424 - 426
  • [43] MR cisternography using a three-dimensional half-Fourier single-shot fast spin-echo sequence
    K. Tsuchiya
    N. Yamakami
    J. Hachiya
    Y. Kassai
    European Radiology, 1998, 8 : 424 - 426
  • [44] Crohn disease with endoscopic correlation: Single-shot fast spin-echo and gadolinium-enhanced fat-suppressed spoiled gradient-echo MR imaging
    Low, RN
    Sebrechts, CP
    Politoske, DA
    Bennett, MT
    Flores, S
    Snyder, RJ
    Pressman, JH
    RADIOLOGY, 2002, 222 (03) : 652 - 660
  • [45] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [46] Comparison of ultrafast half-Fourier single-shot turbo spin-echo sequence with turbo spin-echo sequences for T2-weighted imaging of the female pelvis
    Yamashita, Y
    Tang, Y
    Abe, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1207 - 1212
  • [47] Ultrafast T2-weighted imaging of the abdomen and pelvis: Use of single shot fast spin-echo imaging
    Tang, Y
    Yamashita, Y
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 384 - 390
  • [48] The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma
    Bert De Foer
    Jean-Philippe Vercruysse
    Anja Bernaerts
    Joachim Maes
    Filip Deckers
    Johan Michiels
    Thomas Somers
    Marc Pouillon
    Erwin Offeciers
    Jan W. Casselman
    Neuroradiology, 2007, 49 : 841 - 848
  • [49] The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma
    De Foer, Bert
    Vercruysse, Jean-Philippe
    Bernaerts, Anja
    Maes, Joachim
    Deckers, Filip
    Michiels, Johan
    Somers, Thomas
    Pouillon, Marc
    Offeciers, Erwin
    Casselman, Jan W.
    NEURORADIOLOGY, 2007, 49 (10) : 841 - 848
  • [50] Single-shot Turbo Spin Echo Acquisition for In Vivo Cardiac Diffusion MRI
    Edalati, Masoud
    Lee, Gregory R.
    Wang, Hui
    Taylor, Michael D.
    Li, Yu Y.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 5529 - 5532